X-Link option 2B (MLAG to LAG) topology
This section covers details about X-Link option 2B topology.
Based on the X-Link option 2B topology and the uplink bandwidth option (10 Gbps or 40 Gbps) for the
customer data center connection, use the following port connectivity diagram:
Figure 45. Customer data center network connection
Notes:
• The interconnect switch requires a single 1 Gbps copper connection (RJ45) from the out-of-band (OOB)
management port on the interconnect switch to the management switch or the OOB interconnect
network.
• Ports 51 and 54 of the interconnect switch do not have LED status indicators.
The following tables provide the ports from the interconnect switches which need to be connected to the
customer data center network.
Table 12. 10 Gbps interconnect ports
Interconnect ports
Customer uplink device
Primary interconnect, Mgmt port
Device A – 1 Gbps available port
Primary interconnect, port 46
Device A
Primary interconnect, port 48
Device B
Secondary interconnect, Mgmt port
Device B - 1 Gbps available port
Secondary interconnect, port 46
Device A
Secondary interconnect, port 48
Device B
66
Lenovo ThinkAgile CP Hardware Installation Guide
Содержание ThinkAgile CP 4000 Series
Страница 1: ...Lenovo ThinkAgile CP Hardware Installation Guide Models CP4000 CP6000 ...
Страница 4: ...ii Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 6: ...iv Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 8: ...vi Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 26: ...18 Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 70: ...Figure 42 X Link option 1 topology 62 Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 73: ...Figure 44 X Link topology option 2A Chapter 3 ThinkAgile CP Setup 65 ...
Страница 78: ...70 Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 80: ...72 Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 82: ...74 Lenovo ThinkAgile CP Hardware Installation Guide ...
Страница 83: ......
Страница 84: ......