background image

Lenovo Flex System Fabric EN4093R 10 Gb Scalable Switch

User’s Guide

Содержание Flex System Fabric EN4093R

Страница 1: ...Lenovo Flex System Fabric EN4093R 10 Gb Scalable Switch User s Guide ...

Страница 2: ...Code LAMC document and the Environmental Notices and User Guide document on the Documentation CD included with the product April 2015 Edition Copyright 2015 Lenovo Portions Copyright IBM Corporation 2014 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in...

Страница 3: ...onsole Port 21 The RJ 45 Management Port 22 Handling Transceiver Modules 23 SFP Ports 24 QSFP Ports 26 Locating the Information Panels LEDs and External Ports 28 Information Panel 28 Information LEDs 30 Chapter 3 Configuring the EN4093R 33 Establishing an Interface Through the CMM 35 Enabling Management Through Data Ports 36 Accessing the Switch Through the SSHv2 Telnet Interface 37 Accessing the ...

Страница 4: ... Emission Compliance Statement 55 Avis de Conformité à la Réglementation d Industrie Canada 55 Australia and New Zealand Class A Statement 55 European Union EMC Directive Conformance Statement 56 Germany Class A Statement 56 VCCI Class A Statement 57 Japan Electronics and Information Technology Industries Association JEITA Statement 58 Korea Communications Commission KCC Statement 58 Russia Electr...

Страница 5: ...n kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Πριν εγκαταστήσετε το προϊόν αυτό διαβάστε τις Πληροφορίες ασφαλείας safety information A termék telepítés előtt olvassa el a Biztonsági előírásokat Prima di installare questo prodotto leggere le In...

Страница 6: ...ohto zariadenia si prečítajte Bezpečnostné predpisy Pred namestitvijo tega proizvoda preberite Varnostne informacije Antes de instalar este producto lea la información de seguridad Läs säkerhetsinformationen innan du installerar den här produkten Bu ürünü kurmadan önce güvenlik bilgilerini okuyun Youq mwngz yungh canjbinj neix gaxgonq itdingh aeu doeg aen canjbinj soengq cungj vahgangj ancien suis...

Страница 7: ...ard Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of this product during an electrical storm Connect all power cords to a properly wired and grounded electrical outlet Connect to properly wired outlets any equipment that will be attached to this product When possible use one hand only to connect or disconnect signal cables Never turn on any equipmen...

Страница 8: ...than those specified herein might result in hazardous radiation exposure DANGER Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil À Laser de Classe 1 Statement 25 CAUTION This product contains a Class 1M laser Do not view directly with optical instruments UL Regulatory Information This device is for use only with listed Lenovo Flex System Enterprise Chassis Some laser...

Страница 9: ...enovo Flex System Fabric EN4093R 10 Gb Scalable Switch referred to as EN4093R or switch throughout this document Figure 1 The EN4093R Note The illustrations in this document might differ slightly from your hardware SFP module ports QSFP module ports RS 232 serial port management only RJ 45 External management port Switch status LEDs ...

Страница 10: ...ode port capability fourteen additional internal ports Two external 40 GbE Quad Small Form Pluggable Plus QSFP ports each of which can be optionally used as four SFP ports Upgrade 2 supports eighteen additional ports up to sixty four total Triple compute node port capability fourteen additional internal ports Four additional external SFP ports Note Upgrade 1 is a prerequisite to Upgrade 2 SFP port...

Страница 11: ...ilingual Safety Information document which is on the included Documentation CD Each statement is numbered for reference to the corresponding statement in the Safety Information document The following notices and statements are used in this document Note These notices provide important tips guidance or advice Important These notices provide information or advice that might help you avoid inconvenie...

Страница 12: ...and run the following command from the mnt cd directory sh linux sh When the CD is mounted open the directories and documents that support your product Related Documentation Additional or updated product documents may be available from the Lenovo website Such documents may cover features not described in the original documentation that comes with the switch or may include technical updates or corr...

Страница 13: ... Lenovo Flex System network adapter must be installed in each compute node with which you want to communicate To enable the switch to communicate with a compute node at least one switch must be installed in the Lenovo Flex System chassis For details about network adapter installation configuration and use see the documentation that comes with the Lenovo Flex System network adapter Installing a sec...

Страница 14: ... right most fabric connector on the compute node these I O bays support any switch with the same type of network interface that is used by the corresponding network adapter The compute nodes or Lenovo Flex System chassis that are described or shown in this document might be different from your compute node or Lenovo Flex System chassis For additional information see the documentation that comes wi...

Страница 15: ...red product information locate and record the information shown on Table 1 on page 16 prior to installation An example of the product information labels is shown as follows Figure 3 Sample product labels from the switch Note These examples are to help locate and identify the information labels The actual labels and information for your specific switch may differ The identification labels on the EN...

Страница 16: ...h and so on Orange on a component or an orange label on or near a component on the switch compute node or Lenovo Flex System chassis indicates that the component can be hot swapped which means that if the Lenovo Flex System chassis and operating system support hot swap capability you can remove or install the component while the Lenovo Flex System chassis is running Orange can also indicate touch ...

Страница 17: ...nt can cause static electricity to build up around you The use of a grounding system is recommended For example wear an electrostatic discharge wrist strap if one is available Handle the device carefully holding it by its edges or its frame Do not touch solder joints pins or exposed printed circuitry Do not leave the device where others can handle and damage it While the device is still in its sta...

Страница 18: ...and bay locations see the documentation for the Lenovo Flex System chassis 3 Remove the filler module from the selected bay Store the filler module for future use 4 If you have not already done so touch the static protective package that contains the switch to an unpainted metal surface of the Lenovo Flex System chassis or an unpainted metal surface on any other grounded rack component for at leas...

Страница 19: ...for the switch For information and instructions see Connecting Switch Ports on page 21 and the documentation that comes with the transceiver modules or DACs 12 Attach any cables that are required by the switch For additional information about cabling the switch see Connecting Switch Ports on page 21 the documentation that comes with the port transceiver modules DACs cables and the optional network...

Страница 20: ... plan to replace the switch with another switch you can reuse the existing cables provided they remains securely attached to the network 3 Pull the release latches out from the switch The switch moves out of the bay approximately 0 6 cm 0 25 inch 4 Slide the switch out of the bay and set it aside in a safe static free location 5 Place either another switch or a filler module in the bay Important C...

Страница 21: ...FP transceiver module The switch supports MSA compliant copper DACs up to 5 m 16 5 ft in length The Serial Console Port Connecting the Serial Console Cable To use the serial console connect a serial cable to the RS 232 serial console port of the switch and the other end of the cable to the console device Note You must use one of the two cables in the Serial Access Cable option If your console devi...

Страница 22: ... RJ 45 Cables RJ 45 cables can be connected to the to external management port and also to SFP ports that have legacy 1000BASE T SFP transceiver modules To connect the RJ 45 connector to the switch push the RJ 45 cable connector into the port connector until it clicks into place Disconnecting RJ 45 Cables To disconnect the RJ 45 cable squeeze the release tab and gently pull the cable connector out...

Страница 23: ...the cables You must remove the cable from the transceiver module before you remove the module from the switch port Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable part...

Страница 24: ...h you are installing the switch for at least 2 seconds 3 Read the information in Handling Transceiver Modules on page 23 4 Remove the SFP module from its static protective package 5 If a protective cap is installed in the switch SFP port where you are installing the SFP module remove the cap and store it in a safe place 6 Remove the protective cap from the SFP module and store it in a safe place A...

Страница 25: ... put excess weight on the cable at the connection point Make sure that the cable is well supported To connect the fiber optic cable to the SFP module complete the following steps 1 Remove the protective caps from the end of the fiber optic cable 2 Gently slide the fiber optic cable into the SFP module until it clicks into place 3 Check the LEDs on the switch When the switch is operating correctly ...

Страница 26: ...ive caps on the module and the switch SFP port 7 Place the module into a static protective package QSFP Ports The QSFP ports accept supported QSFP modules The QSFP module provides an MTP cable connector for connecting to external devices Installing a QSFP Module To install a QSFP module in a QSFP port on the switch complete the following steps Note To avoid damage to the cable or the QSFP module d...

Страница 27: ...put excess weight on the cable at the connection point Make sure that the cable is well supported To connect the fiber optic cable to the QSFP module complete the following steps 1 Remove the protective caps from the end of the fiber optic cable 2 Gently slide the fiber optic cable into the QSFP module until it clicks into place 3 Check the LEDs on the switch When the switch is operating correctly...

Страница 28: ...at you disconnect the fiber optic cable before you remove the QSFP module from the switch port 4 Unlock the module by pulling the wire tab straight out as shown in the following illustration 5 Grasp the wire tab on the module and pull it out of the port 6 Replace the protective cap on the module and the switch QSFP port 7 Place the module into a static protective package Locating the Information P...

Страница 29: ...2015 Lenovo Chapter 2 Installing and Removing the EN4093R 29 Figure 4 The EN4093R front panel SFP module ports QSFP module ports RS 232 serial port management only RJ 45 External management port Switch status LEDs ...

Страница 30: ... in the I O module configuration menus and is labeled Mgmt on the switch For additional details see Connecting Switch Ports on page 21 and Port Status LEDs on page 31 Information LEDs The front panel of the switch has LEDs for system and port status The Power Locator and Error LEDs indicate the switch status The Link LINK and Activity TX RX LEDs indicate the status of the external ports Notes A ye...

Страница 31: ...n the CMM this LED is lit to help identify the location of the switch Off The switch has not received a user prompted locator command from the CMM Error Steady yellow When lit this LED indicates a POST failure or critical alert As a result the system error LED on the Lenovo Flex System chassis is also lit Off When this LED is off and the green Power LED is lit it indicates that the switch is worki...

Страница 32: ...32 EN4093R 10 Gb Scalable Switch User s Guide ...

Страница 33: ...ny of the external data ports EXT1 EXT22 in band switch management This mode can be used instead of or in addition to access through the CMM This mode can be enabled only through the CMM configuration interface When this mode is enabled the external ports support both management and data traffic This mode enables the use of additional switch IP addresses on different IP subnets than the CMMs This ...

Страница 34: ...and the Command Reference for your specific switch and its installed firmware For switch communication with a remote management station such as an Lenovo Director management server through the management module external Ethernet port the switch internal network interface and the management module external interface must be on the same IP subnet For specific details about configuring the switch and...

Страница 35: ...rom the CMM using this address One the switch management address is configured you can use it to establish a Secure Shell SSH Telnet session or Web session HTTPS HTTP Note SSH and HTTPs are enabled by default Telnet and HTTP can be enabled once you have initially logged into the switch The Web interface application and the SSHv2 Telnet client software provide different ways to access the same inte...

Страница 36: ...agement port Note External management refers to means other than by the CMM To externally manage the switch additional IP interfaces must be configured For more information see the Application Guide for your specific switch and its installed firmware Data Ports ep option External Mgmt em option Description Disabled Disabled The switch must be managed through the CMM No traffic is allowed on intern...

Страница 37: ...rom accessing the switch or changing its settings To connect to the switch through the SSHv2 Telnet interface refer to your client software for specific instructions on how to invoke a session For example using the Microsoft Telnet Client you would complete the following steps 1 From a DOS command line prompt type telnet switch IP address and press Enter 2 When prompted enter your user name and pa...

Страница 38: ... first time the default switch administrator user name is USERID and the default password is PASSW0RD where the sixth character is the number zero not the letter O The User ID and password fields are case sensitive For security purposes you will be prompted to change the administrator password after the first successful login Otherwise if you have an assigned user account use your assigned user na...

Страница 39: ...case sensitive For security purposes you will be prompted to change the administrator password after the first successful login Otherwise if you have an assigned user account use your assigned user name and password Initial Configuration The operating firmware on the switch contains default configuration files that are installed during the firmware installation These initial configuration settings...

Страница 40: ...40 EN4093R 10 Gb Scalable Switch User s Guide ...

Страница 41: ...witch and installed firmware Determining the Level of Switch Firmware After you install the switch in the Lenovo Flex System chassis make sure that the latest firmware is installed on the switch To determine the level of the firmware that is installed complete the following steps 1 Log on to the Lenovo Flex System Chassis Management Module CMM Command Line Interface CLI as described in the CMM doc...

Страница 42: ...de the switch firmware by using an FTP TFTP or SFTP file server Typically the file server runs as an application under your operating system Make sure that the file server application is installed on your file server then download the switch firmware images from the Lenovo website into a directory on your file server Then enable the file server and set its default directory to the directory where ...

Страница 43: ...e file name of the firmware image as it appears in the file server operating system 3 Execute the following command to upload the boot image to the switch Where boot file is the file name of the boot image as it appears in the file server operating system 4 Reset and restart the switch as described in Resetting and Restarting the Switch on page 44 Network entity IP address Mask FTP TFTP or SFTP fi...

Страница 44: ...mple 3 Execute the reset command to restart the switch 4 Wait for the POST to complete This may take up to 2 minutes 5 Execute the info command for the switch that was just restarted and note the corresponding level of the firmware for the switch Confirm that the firmware build number reflects the correct firmware release For example system env T system switch 1 system switch 1 reset system switch...

Страница 45: ...ated on the part number PN label bottom or rear of switch module and is also displayed during a login to any of the user interfaces For example SN UID Y250CM294998 For more information about locating the switch identification labels see Before Installing the EN4093R on page 15 In the event of the switch replacement new activation key files based on the serial number of the replacement unit must be...

Страница 46: ...the copy running config startup config command This command stores the current switch configuration and all changes to nonvolatile memory Both license key files can be installed prior to the switch reset in order to activate both at the same time Complete the following steps to install feature licenses 1 Log in to the switch see Configuring the EN4093R on page 33 for more information 2 At the swit...

Страница 47: ...n the chassis are lit An event is stored in the event log in the system status panel of the CMM The specific failure is displayed on the system status I O module panel of the CMM Note For the locations and descriptions of the switch LEDs see Locating the Information Panels LEDs and External Ports on page 28 POST Errors There are two types of errors noncritical and critical A noncritical error appl...

Страница 48: ...nformation window Be sure to note the applicable error code and corresponding failure You might have to provide this information when you call for service For details see Getting Help and Technical Assistance on page 49 Diagnostic indicator in hex Failing functional area Failure criticality 00 7F Base internal functions Critical 80 9F Internal interface failures Noncritical A0 AF External interfac...

Страница 49: ...e connected Check the power switches to make sure that the system and any optional devices are turned on Check for updated software firmware and operating system device drivers for your Lenovo product The Lenovo Warranty terms and conditions state that you the owner of the Lenovo product are responsible for maintaining and updating all software or firmware for the product unless it is covered by a...

Страница 50: ...50 EN4093R 10 Gb Scalable Switch User s Guide ...

Страница 51: ...ss or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication Lenovo may make improvements and or changes in the product s and or the program s described in this p...

Страница 52: ...performance CD or DVD drive speed is the variable read rate Actual speeds vary and are often less than the possible maximum When referring to processor storage real and virtual storage or channel volume KB stands for 1 024 bytes MB stands for 1 048 576 bytes and GB stands for 1 073 741 824 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and G...

Страница 53: ...from its retail version if available and might not include user manuals or all program functionality Recycling information Lenovo encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed Lenovo offers a variety of programs and services to assist equipment owners in recycling their IT products For information on recycling Lenovo pro...

Страница 54: ...ce Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination Implementation of such remedial measures is a customer responsibility Contaminant Limits Particulate The room air must be continuously filtered with 40 atmospheric dust spot efficiency MERV 9 according to ASHRAE Standard 52 2...

Страница 55: ...e instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Lenovo is not responsible for any radio or t...

Страница 56: ...108 EC früher 89 336 EWG für Geräte der Klasse A Dieses Gerät ist berechtigt in übereinstimmung mit dem Deutschen EMVG das EG Konformitätszeichen CE zu führen Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo Deutschland GmbH Gropiusplatz 10 D 70563 Stuttgart Informationen in Hinsicht EMVG Paragraf 4 Abs 1 4 Das Gerät erfüllt die Schutzanforderungen nach EN 55024...

Страница 57: ...as Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A Nach der EN 55022 Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Maßnahmen durchzuführen und dafür aufzukommen Nach dem EMVG Geräte dürfen an Orten für die sie nicht ausreichend entstört sind nur mit beson...

Страница 58: ...nd Information Technology Industries Association JEITA Confirmed Harmonics Guidelines with Modifications products greater than 20 A per phase Korea Communications Commission KCC Statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A Stateme...

Отзывы: