Bauer
6 Maintenance, malfunctions
GEL 2432 / 244x
43
English
6 Maintenance,
malfunctions
The MiniCODER does not contain any moving parts and is therefore largely mainte-
nance-free.
Maintenance
When?
What?
MiniCODER faulty
►
Replace the MiniCODER.
Regularly
►
Check the MiniCODER for damage.
►
Make sure there are no foreign bodies in the installation space
for the MiniCODER.
►
Clean the MiniCODER with water or a non-corrosive cleaning
agent.
Do not use a high pressure cleaner.
Troubleshooting
Malfunction
Possible causes
Remedy
No output signal or
erroneous output
signal
Electrical connection
faulty
Check all electrical connections be-
tween MiniCODER and power sup-
ply, as well as the evaluation elec-
tronics for correctness and secure
contact, and ensure they are dry.
Incorrect air gap between
measuring surface and
target wheel
Check whether the required value
is maintained in all (climatic) condi-
tions over a complete target wheel
revolution.
Using a torque wrench, check
whether the fastening screws on
the sensor flange are correctly
tightened.
Measuring surface of tar-
get wheel damaged
Replace the damaged component.
Determine the cause of the dam-
age and rectify it.
Counting direction
incorrect
Track assignment incor-
rect
Check the connections for the track
signals and change them if neces-
sary (direction of rotation assign-
ment: