AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230
TXV
36,200
16.20
12.00
CX34-49
SLP98UH090V36C
4020686
XC16-036-230
TXV
36,600
16.50
12.00
CX34-49
SLP98UH090V48C
4020687
XC16-036-230
TXV
36,600
16.50
12.00
CX34-49
SLP98UH090V60C
4020688
XC16-036-230
TXV
36,600
16.50
12.20
CX34-49
SLP98UH110V60C
4020689
XC16-036-230
TXV
35,600
14.50
11.00
CX34-49
3068637
XC16-048-230
TXV
45,500
14.70
11.50
C33-44C
G61MPV-60C-090
1003983
XC16-048-230
TXV
45,500
14.70
11.20
C33-44C
G61MPV-60C-091
1046650
XC16-048-230
TXV
45,500
14.50
11.50
C33-44C
G61MPV-60C-110
1003988
XC16-048-230
TXV
45,500
14.50
11.50
C33-44C
G61MPV-60C-111
1046651
XC16-048-230
TXV
45,500
14.70
11.20
C33-48
G61MPV-60C-091
1046652
XC16-048-230
TXV
45,500
14.50
11.50
C33-48
G61MPV-60C-110
1003986
XC16-048-230
TXV
45,500
14.50
11.50
C33-48
G61MPV-60C-111
1046653
XC16-048-230
TXV
45,000
14.20
11.20
C33-48
O23V5-140/154
1038249
XC16-048-230
TXV
46,000
15.00
11.70
C33-48
SL280UH090V60C
3933036
XC16-048-230
TXV
46,000
15.00
11.70
C33-48
SL280UH090XV60C
4235458
XC16-048-230
TXV
45,500
14.70
11.70
C33-48
SL280UH110V60C
3933037
XC16-048-230
TXV
45,500
14.70
11.70
C33-48
SL280UH110XV60C
4040519
XC16-048-230
TXV
45,500
13.70
11.20
C33-48
1003999
XC16-048-230
TXV
47,500
15.20
12.00
C33-49
G61MPV-60C-090
1003774
XC16-048-230
TXV
47,500
15.00
11.70
C33-49
G61MPV-60C-091
1046654
XC16-048-230
TXV
47,500
15.00
12.00
C33-49
G61MPV-60C-110
1003775
XC16-048-230
TXV
47,000
15.00
11.70
C33-49
G61MPV-60C-111
1046655
XC16-048-230
TXV
46,500
14.70
11.70
C33-49
O23V5-140/154
1038250
XC16-048-230
TXV
47,500
15.70
12.20
C33-49
SL280UH090V60C
3933038
XC16-048-230
TXV
47,500
15.70
12.20
C33-49
SL280UH090XV60C
4235459
XC16-048-230
TXV
47,500
15.50
12.20
C33-49
SL280UH110V60C
3933039
XC16-048-230
TXV
47,500
15.50
12.20
C33-49
SL280UH110XV60C
4040520
XC16-048-230
TXV
47,000
14.20
11.70
C33-49
1003730
XC16-048-230
TXV
46,000
15.20
11.20
C33-50/60C
CBWMV-60C-100
1088641
XC16-048-230
TXV
46,000
15.00
11.70
C33-50/60C
G61MPV-60C-090
1003766
XC16-048-230
TXV
46,000
14.70
11.50
C33-50/60C
G61MPV-60C-091
1046656
XC16-048-230
TXV
46,000
14.70
11.70
C33-50/60C
G61MPV-60C-110
1003768
XC16-048-230
TXV
46,000
14.70
11.70
C33-50/60C
G61MPV-60C-111
1046657
XC16-048-230
TXV
46,000
14.50
11.20
C33-50/60C
O23V5-140/154
1038251
XC16-048-230
TXV
46,500
15.20
11.70
C33-50/60C
SL280UH090V60C
3933040
XC16-048-230
TXV
46,500
15.20
11.70
C33-50/60C
SL280UH090XV60C
4235460
XC16-048-230
TXV
46,000
15.00
11.70
C33-50/60C
SL280UH110V60C
3933041
XC16-048-230
TXV
46,000
15.00
11.70
C33-50/60C
SL280UH110XV60C
4040521
XC16-048-230
TXV
46,500
13.70
11.20
C33-50/60C
1003726
XC16-048-230
TXV
47,000
15.50
12.20
C33-60D
G61MPV-60D-135
3133211
XC16-048-230
TXV
46,500
15.00
11.50
C33-60D
O23V5-140/154
1003981
XC16-048-230
TXV
47,000
15.50
12.20
C33-60D
SL280UH135V60D
3933042
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.