XC16 - 2 to 5 Ton Air Conditioner / Page 16
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230
TXV
34,000
13.70
10.70
CR33-48
3068639
XC16-036-230
TXV
34,400
15.50
11.20
CX34-36
CBWMV-36C-090
3184067
XC16-036-230
TXV
34,200
15.20
11.00
CX34-36
G61MPV-36B-045
3068653
XC16-036-230
TXV
34,400
15.50
11.00
CX34-36
G61MPV-36B-070
3068654
XC16-036-230
TXV
34,200
15.20
11.00
CX34-36
G61MPV-36B-071
3068656
XC16-036-230
TXV
34,200
15.50
11.50
CX34-36
G61MPV-36C-090
3068657
XC16-036-230
TXV
34,200
15.50
11.20
CX34-36
SL280UH070V36A
3933016
XC16-036-230
TXV
34,200
15.50
11.20
CX34-36
SL280UH070XV36A
4037924
XC16-036-230
TXV
34,400
15.70
11.50
CX34-36
SL280UH090V36B
3933017
XC16-036-230
TXV
34,400
15.50
11.50
CX34-36
SL280UH090V48B
3933018
XC16-036-230
TXV
34,800
15.70
11.70
CX34-36
SL280UH090V60C
3933019
XC16-036-230
TXV
34,400
15.50
11.50
CX34-36
SL280UH090XV48B
4038684
XC16-036-230
TXV
34,800
15.70
11.70
CX34-36
SL280UH090XV60C
4235454
XC16-036-230
TXV
34,600
15.70
11.50
CX34-36
SL280UH110V60C
3933020
XC16-036-230
TXV
34,600
15.70
11.50
CX34-36
SL280UH110XV60C
4040514
XC16-036-230
TXV
34,200
15.50
11.20
CX34-36
SLP98UH070V36B
4020670
XC16-036-230
TXV
34,400
15.70
11.50
CX34-36
SLP98UH090V36C
4020671
XC16-036-230
TXV
34,600
15.70
11.50
CX34-36
SLP98UH090V48C
4020672
XC16-036-230
TXV
34,600
15.70
11.50
CX34-36
SLP98UH110V60C
4020673
XC16-036-230
TXV
33,800
13.70
10.70
CX34-36
3068632
XC16-036-230
TXV
35,600
16.00
11.20
CX34-38
G61MPV-36B-045
3068661
XC16-036-230
TXV
35,400
16.00
11.50
CX34-38
G61MPV-36B-070
3068662
XC16-036-230
TXV
35,400
16.00
11.50
CX34-38
G61MPV-36B-071
3068664
XC16-036-230
TXV
35,600
16.00
11.50
CX34-38
SL280UH070V36A
3933021
XC16-036-230
TXV
35,600
16.00
11.50
CX34-38
SL280UH070XV36A
4037925
XC16-036-230
TXV
35,800
16.20
11.70
CX34-38
SL280UH090V36B
3933022
XC16-036-230
TXV
35,800
16.00
12.00
CX34-38
SL280UH090V48B
3933023
XC16-036-230
TXV
35,800
16.00
12.00
CX34-38
SL280UH090XV48B
4038689
XC16-036-230
TXV
35,600
16.20
11.50
CX34-38
SLP98UH070V36B
4020674
XC16-036-230
TXV
34,600
14.00
10.90
CX34-38
3068633
XC16-036-230
TXV
34,200
15.20
11.00
CX34-42
G61MPV-36B-045
3068666
XC16-036-230
TXV
34,000
15.20
11.00
CX34-42
G61MPV-36B-070
3068667
XC16-036-230
TXV
34,000
15.20
11.00
CX34-42
G61MPV-36B-071
3068669
XC16-036-230
TXV
34,400
15.70
11.50
CX34-42
SL280UH090V36B
3933024
XC16-036-230
TXV
34,400
15.50
11.50
CX34-42
SL280UH090V48B
3933025
XC16-036-230
TXV
34,400
15.50
11.50
CX34-42
SL280UH090XV48B
4038694
XC16-036-230
TXV
34,200
15.50
11.20
CX34-42
SLP98UH070V36B
4020675
XC16-036-230
TXV
33,800
13.70
10.70
CX34-42
3068634
XC16-036-230
TXV
35,800
16.00
11.70
CX34-43
CBWMV-36C-090
3184069
XC16-036-230
TXV
35,600
16.00
11.50
CX34-43
G61MPV-36B-045
3068672
XC16-036-230
TXV
35,400
16.00
11.50
CX34-43
G61MPV-36B-070
3068673
XC16-036-230
TXV
35,400
16.20
12.00
CX34-43
G61MPV-36C-090
3068675
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.
Содержание XC16