BLOWER DATA
SLP99DF090XV48C BLOWER PERFORMANCE (less filter)
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35%
40%
50%
60%
70%
80%
90%
100%
Increase (+15%) Heat CFM
723
790
925
1060
1195
1329
1464
1599
Increase (+7.5%) Heat CFM
690
752
878
1004
1129
1255
1381
1507
Default Heat CFM
656
714
831
948
1064
1181
1297
1414
Decrease (-7.5% ) Heat CFM
601
654
761
867
974
1081
1188
1295
Decrease (-15% ) Heat CFM
545
593
690
787
884
981
1078
1175
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Low
Medium-
Low
Medium
High
High
(Default)
Low
Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM
775
940
1100
1255
1120
1340
1535
1745
Default Cool CFM
690
875
975
1135
1000
1220
1425
1625
Decrease (-10%) Cool CFM
635
755
915
1025
920
1100
1270
1470
SLP99DF090XV60C BLOWER PERFORMANCE (less filter)
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35%
40%
50%
60%
70%
80%
90%
100%
Increase (+15%) Heat CFM
653
728
877
1027
1176
1326
1475
1625
Increase (+7.5%) Heat CFM
603
673
813
953
1092
1232
1372
1512
Default Heat CFM
553
618
748
878
1009
1139
1269
1399
Decrease (-7.5% ) Heat CFM
510
570
690
811
931
1051
1171
1292
Decrease (-15% ) Heat CFM
467
522
632
743
853
963
1074
1184
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Low
Medium-
Low
Medium
High
High
(Default)
Low
Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM
1110
1265
1395
1600
1600
1750
1965
2130
Default Cool CFM
1000
1145
1275
1445
1445
1625
1805
1975
Decrease (-10%) Cool CFM
885
1060
1145
1265
1265
1445
1645
1805
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single-stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times.
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages.
Cool Mode Available (Cooling Blower Performance Table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28% and 38% (DIP switch selectable) of the same second-stage COOL speed position minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 380 cfm.