background image

2

LENNOX HEARTH PRODUCTS  •  MERIT PLUS

®

 B-VENT GAS FIREPLACES (MPB33/35/40/45)  •  CARE AND OPERATION INSTRUCTIONS

Safety and 

Your Fireplace

 To prevent severe burns and injuries, install 

a screen or physical barrier to prevent direct 
contact with the glass.

To order a FREE Lennox

®

 

SAFETY GUARD 

for your fi replace, see details at left.

 Follow the safety instructions below 

and be sure everyone in your household 
understands this burn hazard:

• The surfaces on your fi replace get 

EXTREMELY HOT! 

• The glass on the front 

of the fi replace reaches 
EXTREMELY HIGH 
temperatures and can 
cause severe burns if touched.

• Keep children away from an operating 

fi replace. Closely supervise children in 
any room where a fi replace is operating 
to prevent contact with glass.

• Keep clothing, furniture, 

gasoline, and other 
fl ammable liquids away 
from the fi replace.

• Even after the gas is turned off, fi replace 

surfaces remain extremely hot.

 Be sure to attach the enclosed 

Safety-in-

Operation Warnings

 where you turn on your 

fi replace, to help remind everyone of the 
dangers associated with high temperatures 
(see 

Page 5

).

 Read 

Important Safety Information

 on 

Page 4

.

All parts of your Lennox 

Hearth Products fi replace 

get EXTREMELY HOT! 

Table of Contents

Safety and Your Fireplace

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2

Important Safety Information

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

Attaching Safety-in-Operation Warnings

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

Appliance Installation, Service, and Maintenance Notices . . . . . . . . . . . . . . . . . 6
Appliance Operation Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
   BTU Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
   Gas Pressure Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
   Orifi ce Sizes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
   Burn-In Period  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operation and Care of Your Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Gas Controls/Control Compartment Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Variable Flame Height Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Vent Operation Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Replacing The Safety Limit Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Front Glass Enclosure Panel, Removal and Installation . . . . . . . . . . . . . . . . . . 11
Install Volcanic Stone, Glowing Embers, and Logs  . . . . . . . . . . . . . . . . . . . . . 12
Burner Flame Appearance/Sooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Burner Flame Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Millivolt Appliance Checkout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Wiring Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Ordering Replacement Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Product Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Optional Remote Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Accessory Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Lighting Instructions – Millivolt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Troubleshooting Guide – Millivolt Gas Control System  . . . . . . . . . . . . . . . . . . 25
Replacement Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

 

FREE

 

SAFETY

 

GUARD

 

OFFER

 

The Lennox

®

 

SAFETY GUARD

 protects against 

severe burns and injuries by preventing direct contact

with the front glass surface of your fi replace.

To receive your FREE 

SAFETY GUARD

, call 

1-800-655-2008 

or visit

www.LennoxHearthProducts.com

 

(> Owner Resources > Safety First).

Note: Safety Guards may not be available for some 

older models that are no longer in production.

Thank you for your purchase. We appreciate your business!

Please carefully read and follow all instructions in this manual. 

Pay special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help ensure 
many years of dependable and enjoyable service from your fi replace.

Register your product online today! 

To help us keep you up-to-date on product information and offers, 
please take a few moments to register your product online at:

www.LennoxHearthProducts.com 

> Owner Resources > Product 

Registration

 

Содержание MPB33CNM

Страница 1: ...If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death s 4 33 7 53 52 3 s 4 4 5 33 5 4 s 6 2 7 2 4 4 5 33 s 5...

Страница 2: ...ssure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Gas Controls Control Compartment Access 8 Variable Flame Height Adjustment 8 Vent Operation Test 8 Replacin...

Страница 3: ...sez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evit...

Страница 4: ...vent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer o...

Страница 5: ...manera 1 Identifique el interruptor de pared que controla la chimenea verifique que el interruptor opera la chimenea encendi ndola y apag ndola Limpie bien la placa del interruptor de pared para quita...

Страница 6: ...il fonctionne Ne pas toucher l appareil Risque de br lures graves Surveiller les enfants Garder les v tements les meubles l essence ou autres liquides produisant des vapeur inflammables loin de l app...

Страница 7: ...nts used in the manufacturing process Depending on your use the burn in period may take a few hours or a few days KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS THE ODOR AND HAZE EMITTED DU...

Страница 8: ...racted position and then close the panel Refer to Figure 1 for access to the gas control valve Millivolt appliances will be fitted with the gas control valve shown in Figure 2 MILLIVOLT APPLIANCES To...

Страница 9: ...oop Scoop Securing Screws Firebox Top Lintel Securing Screw Hole in Cabinet Top Figure 3 Safety Limit Switch Blocked Flue Safety Limit Switch Location Inside View of Firebox Top Right Side Intersectio...

Страница 10: ...cleaning solutions are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner INSPECT GLASS GASKET Visually inspect...

Страница 11: ...only when the front glass enclosure panels are installed Generally the front glass enclosure panel should not be removed except to gain access to the components within the firebox REMOVING GLASS ENCL...

Страница 12: ...ent log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very hot and will remain hot up to one hour after gas supply is tur...

Страница 13: ...er end Place the left log and then the smaller left and right top logs All logs that have notches to fit over the grate tines should be positioned with these notches directly against the grate All top...

Страница 14: ...osition the right log log no 3 by inserting the pin from the rear log into the hole on its upper end Place the left log and then the smaller left and right top logs All logs that have notches to fit o...

Страница 15: ...glowing embers as shown in Figure 6 Place the rear log both the right and left and then the smaller left and right top logs All logs that have notches to fit over the grate tines should be positioned...

Страница 16: ...e shutter opening must be adjusted between these two extremes AIR SHUTTER ADJUSTMENT GUIDELINES If there is smoke or soot present first check the log set positioning to ensure that the flames are not...

Страница 17: ...to a more open position until the proper flame appearance is achieved If flame remains blue adjust the air shutter incrementally to a more closed position until the proper flame appearance is achieved...

Страница 18: ...S VALVES THERMOPILE GAS VALVE If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile H T P T H T P T TWIST WIRES A AND B TOGETHER TO OPER...

Страница 19: ...s switched on TURNING OFF THE APPLIANCE If the appliance and the remote control are switched on when the ON OFF key is pressed Figure 19 the Remote control is turned off The receiver beeps 2 times LOW...

Страница 20: ...quipped fireplaces only Rocker Switch Kit 80L41 FRS Forced Air Blower Kit The FBK 100 blower assembly provides con stant velocity forced air circulation The FBK 200 blower assembly provides variable s...

Страница 21: ...e in three styles They are easy to install onto the standard glass door frame Includes heavy duty magnetic door latches and functional twin pane doors Cat No Model Description Where Used H8769 AD35B 2...

Страница 22: ...s necessary Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Glowing Embers Homeowner Qualified Services Technician...

Страница 23: ...ot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician o...

Страница 24: ...lle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un technicien qualifi ou le fournisseur de gaz Si la v...

Страница 25: ...me impingement on thermocouple Ensure that the connection between the valve and thermocouple are tight and secure Pilot burning no gas to burner valve knob ON wall switch ON Limit Switch defective Iso...

Страница 26: ...h Door Magnetic 69L31 2 69L31 2 69L31 2 69L31 2 8 Log Set Complete 24M15 1 H6197 1 24M25 1 24M25 1 9 Burner Assembly H8585 1 H8585 1 H8587 1 H8587 1 10 Grate Assembly H6526 1 H6526 1 H6314 1 H6314 1 1...

Страница 27: ...OT TO SCALE LENNOX HEARTH PRODUCTS MERIT PLUS B VENT GAS FIREPLACES MPB33 35 40 45 CARE AND OPERATION INSTRUCTIONS REPLACEMENT PARTS 7 4 5 14 9 40 45 9 33 35 17 16 10 40 45 33 35 10 12 13 19 18 20 22...

Страница 28: ...local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industr...

Отзывы: