WARRANTY INFORMATION

Your gas appliance is covered by a limited 
twenty-year warranty. You will fi nd a copy 
of the warranty accompanying this manual. 
Please read the warranty to be familiar with its 
coverage.

Retain this manual. File it with your other 
documents for future reference.

Failure to comply with the installation and 
operating instructions provided will result 
in an improperly installed and operating 
appliance, voiding its warranty.

Do not attempt to alter or modify the 
construction of the appliance or its 
components. Any modifi cation or alteration 
may void the warranty, certifi cation, and 
listings of this unit.

GENERAL INFORMATION

Millivolt appliances have a millivolt gas 
control valve with piezo ignition system. If any 
optional accessories that will require electrical 
power are to be installed, the electrical power 
must be provided at the time of appliance 
installation. 

These appliances comply with National 
Safety Standards and are tested and listed 
by OMNI-Test Laboratories, Inc. (Report 
No. 116-F-36d-5) to ANSI Z21.50b-2009 (in 
Canada, CGA 2.22b-2009), and CAN/CGA-
2.17-M91 (R2009) in both USA and Canada, 
as vented gas fi replaces.

These fi replaces are vented gas appli ances. 
Do not burn wood or other material in these 
appliances.

This appliance is only for use with the 
type of gas indicated on rating plate. This 
appliance is not convertible for use with 
other gases, unless a certifi ed kit is used.

These appliances are designed to operate on 
natural gas or propane gas only. The use of 
other fuels or combinations of fuels will degrade 
the performance of this system and may be 
dangerous.

Cet appareil doit être utilisé uniquement 
avec les types de gaz indiqués sur la plaque 
signalétique. Ne pas l’utiliser avec d’autres 
gaz sauf si un kit de conversion certifi é est 
installé.

Provide adequate clearances around 
air openings and adequate accessibility 
clearance for service and proper operation. 
Never obstruct the front openings of the 
appliance.

Do not use this appliance if any part has 
been under water. Immediately call a 
qualifi ed service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control that has 
been under water.

These fi replaces are designed as decor-ative 
appliances and are not intended for use as 
area heaters. They must not be
equipped with wall thermostats or remote 
controls with thermostat functions.

CAUTION: Hot while in operation. Do not 
touch. Severe Burns may result. Keep 
children, clothing furniture, gasoline and 
other liquids having fl ammable vapors 
away.

ATTENTION : L’appareil est chaud lorsqu’il 
fonctionne. Ne pas toucher l’appareil. 
Risque de brûlures graves. Surveiller 
les enfants. Garder les vêtements, les 
meubles, l’essence ou autres liquides 
produisant des vapeur infl ammables loin de 
l’appareil.

This appliance uses room air for 
combustion. It is imperative that provisions 
for adequate combustion and ventilation air 
be made. This appliance is NOT designed to 
and will not operate in a negative pressure. 
Contact your dealer if you suspect such a 
situation exists.

APPLIANCE INSTALLATION, SERVICE, 
AND MAINTENANCE NOTICES

WARNING: Improper installation, 
adjustment, alteration, service or 
maintenance can cause injury or property 
damage. Refer to the owner’s information 
manual provided with this appliance. For 
assistance or additional information consult 
a qualifi ed installer, service agency or the 
gas supplier.

AVERTISSEMENT : Une installation, un 
réglage, une modifi cation, une réparation 
ou un entretien mal effectué peut 
causer des dommages matériels ou des 
blessures. Voir la notice de l’utilisateur 
qui accompgne l’appareil. Pour de l’aide 
ou des renseignements supplémentaires, 
consultez un installateur, un technicien 
agréé ou le fournisseur de gaz.

Only trim kit(s) supplied by the 
manufacturer shall be used in the 
installation of this appliance.

Seules les trousses de garniture fournies 
par le fabricant doivent être utilisées pour 
l’installation de cet appareil.

These appliances must not be connected to a 
chimney or fl ue serving a separate solid fuel 
burning appliance. 

Draft relief openings must not be covered or 
blocked.

Any change to this appliance and/or its 
operating controls is dangerous. Improper 
installation or use of this appliance can 
cause serious injury or death from fi re, 
burns, explosion or carbon monoxide 
poisoning.

CARBON MONOXIDE POISONING 

Early signs of carbon monoxide poisoning 
are similar to the fl u with headaches, 
dizziness and/or nausea. If you have these 
signs, obtain fresh air immediately. Turn 
off the gas supply to the appliance and 
have it serviced by a qualifi ed professional, 
as it may not be operating correctly. 
Some people are more affected by carbon 
monoxide than others, including pregnant 
women, people with heart or lung disease 
or anemia, those under the infl uence of 
alcohol, and those at high altitudes.

Turn off gas and electrical power to the 
fi replace and allow it to cool before 
cleaning or servicing the appliance.

Appliance Operation Notices

Do not operate appliance with the glass 
front removed, cracked, or broken.

       

WARNING

B-Vent appliances are not 
designed to operate in negatively 
pressured environments (pres-
sure within the home is less than 
pressures outside). Signifi cant 
negatively pressured environ-
ments caused by weather, home 
design, or other devices may 
impact the operation of these 
appliances.  Negative pres-
sures may result in poor fl ame 
appearance, sooting, damage to 
property and/or severe personal 
injury. Do not operate these 
appliances in negatively pres-
sured environments.

Содержание MPB33CNM

Страница 1: ...If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death s 4 33 7 53 52 3 s 4 4 5 33 5 4 s 6 2 7 2 4 4 5 33 s 5...

Страница 2: ...ssure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Gas Controls Control Compartment Access 8 Variable Flame Height Adjustment 8 Vent Operation Test 8 Replacin...

Страница 3: ...sez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evit...

Страница 4: ...vent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer o...

Страница 5: ...manera 1 Identifique el interruptor de pared que controla la chimenea verifique que el interruptor opera la chimenea encendi ndola y apag ndola Limpie bien la placa del interruptor de pared para quita...

Страница 6: ...il fonctionne Ne pas toucher l appareil Risque de br lures graves Surveiller les enfants Garder les v tements les meubles l essence ou autres liquides produisant des vapeur inflammables loin de l app...

Страница 7: ...nts used in the manufacturing process Depending on your use the burn in period may take a few hours or a few days KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS THE ODOR AND HAZE EMITTED DU...

Страница 8: ...racted position and then close the panel Refer to Figure 1 for access to the gas control valve Millivolt appliances will be fitted with the gas control valve shown in Figure 2 MILLIVOLT APPLIANCES To...

Страница 9: ...oop Scoop Securing Screws Firebox Top Lintel Securing Screw Hole in Cabinet Top Figure 3 Safety Limit Switch Blocked Flue Safety Limit Switch Location Inside View of Firebox Top Right Side Intersectio...

Страница 10: ...cleaning solutions are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner INSPECT GLASS GASKET Visually inspect...

Страница 11: ...only when the front glass enclosure panels are installed Generally the front glass enclosure panel should not be removed except to gain access to the components within the firebox REMOVING GLASS ENCL...

Страница 12: ...ent log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very hot and will remain hot up to one hour after gas supply is tur...

Страница 13: ...er end Place the left log and then the smaller left and right top logs All logs that have notches to fit over the grate tines should be positioned with these notches directly against the grate All top...

Страница 14: ...osition the right log log no 3 by inserting the pin from the rear log into the hole on its upper end Place the left log and then the smaller left and right top logs All logs that have notches to fit o...

Страница 15: ...glowing embers as shown in Figure 6 Place the rear log both the right and left and then the smaller left and right top logs All logs that have notches to fit over the grate tines should be positioned...

Страница 16: ...e shutter opening must be adjusted between these two extremes AIR SHUTTER ADJUSTMENT GUIDELINES If there is smoke or soot present first check the log set positioning to ensure that the flames are not...

Страница 17: ...to a more open position until the proper flame appearance is achieved If flame remains blue adjust the air shutter incrementally to a more closed position until the proper flame appearance is achieved...

Страница 18: ...S VALVES THERMOPILE GAS VALVE If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile H T P T H T P T TWIST WIRES A AND B TOGETHER TO OPER...

Страница 19: ...s switched on TURNING OFF THE APPLIANCE If the appliance and the remote control are switched on when the ON OFF key is pressed Figure 19 the Remote control is turned off The receiver beeps 2 times LOW...

Страница 20: ...quipped fireplaces only Rocker Switch Kit 80L41 FRS Forced Air Blower Kit The FBK 100 blower assembly provides con stant velocity forced air circulation The FBK 200 blower assembly provides variable s...

Страница 21: ...e in three styles They are easy to install onto the standard glass door frame Includes heavy duty magnetic door latches and functional twin pane doors Cat No Model Description Where Used H8769 AD35B 2...

Страница 22: ...s necessary Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Glowing Embers Homeowner Qualified Services Technician...

Страница 23: ...ot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician o...

Страница 24: ...lle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un technicien qualifi ou le fournisseur de gaz Si la v...

Страница 25: ...me impingement on thermocouple Ensure that the connection between the valve and thermocouple are tight and secure Pilot burning no gas to burner valve knob ON wall switch ON Limit Switch defective Iso...

Страница 26: ...h Door Magnetic 69L31 2 69L31 2 69L31 2 69L31 2 8 Log Set Complete 24M15 1 H6197 1 24M25 1 24M25 1 9 Burner Assembly H8585 1 H8585 1 H8587 1 H8587 1 10 Grate Assembly H6526 1 H6526 1 H6314 1 H6314 1 1...

Страница 27: ...OT TO SCALE LENNOX HEARTH PRODUCTS MERIT PLUS B VENT GAS FIREPLACES MPB33 35 40 45 CARE AND OPERATION INSTRUCTIONS REPLACEMENT PARTS 7 4 5 14 9 40 45 9 33 35 17 16 10 40 45 33 35 10 12 13 19 18 20 22...

Страница 28: ...local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industr...

Отзывы: