background image

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DLX POWER VENT DV GAS FIREPLACES (MDLX40/45IN-PV)  •  CARE AND OPERATION INSTRUCTIONS

25

Power Vent Motor 

Is Working?

Does the Pilot 

Spark?

Pilot Burner 

Lights?

Does Spark 

Stop When Pilot 

Lights?

Does Main Burner 

Light?

System Runs 

Continuously 

Until 

Switched OFF?

START

ON/OFF Switch or Remote 

ON? Is There 120 V Power 

to the Fireplace? Are All 

Wiring Connections Tight? 

(Turn OFF Power Before 

Checking)

Yes

No

Yes

Is There 120V Power 

to the Motor?

Replace Blower

Yes

Yes

Is the Pressure 

Switch Closed?

No

No

No

Is There Blockage in the Vent? 

Is There Water/Dirt in the Hose from 

the Blower to the Pressure Switch? 

Are the Hose Connections Loose? 

Is the Hose Cracked?

Replace Pressure 

Switch

Replace Control 

Module

Yes

Yes

Is the Lead to the 

Spark Electrode 

Attached or Arcing 

to Ground? Is the 

Electrode Cracked?

No

Replace Ignition Module

Is Pilot Gas Line 

Blocked? Is Pilot 

Orifice Blocked?

No

Yes

Yes

Replace Pilot

Does Pilot Flame 

Cover the Flame 

Rod?

No

Yes

No

Is the Flame Rod Corroded? 

Is the Pilot Hood Corroded?

Is Flame Rod Insulator Cracked?

Is Wire to Flame Rod Damaged?

Replace Ignition Module

Check Pilot for Obstruction. 

Check Gas Pressure. 

Adjust Pilot Flame.

No

Yes

No

Are Wires to Valve 

Loose Or Corroded?

No

Is There Manifold Pressure?

Replace Gas Valve

No

Yes

Check Position of 

Pilot. Is Orifice 

Blocked?

No

Replace Ignition Module

No

Does the Pilot Flame Cover the Flame Rod?

Is the Sensor Wire in Good Condition?

Is There Continuity to Ground from the Pilot Burner?

No

Replace Control Module

Does Pressure Switch Open During Operation?

Yes

No

Replace Ignition Module

Yes

Is Vent Partially Blocked?

Is There Water/Dirt in Hose to Pressure Switch?

Are Hose Connections Loose?

Is the Hose Cracked?

Replace Pressure Switch

No

Replace Control Module

No

Does System Run 

Continue?

Replace Ignition 

Module

No

Yes

WARNING: Never Jump The Pressure 

Switch Out Of This System. Property 

Damage, Injury Or Death May Result. 

Unit Will Not Start If Pressure Switch 

Is Jumped.

Is Presure 

Switch Open 

When Unit Is 

Turned OFF?

Yes

No

Replace Pressure 

Switch (Ensure 

Power Vent Motor 

Is NOT Running)

TROUBLESHOOTING GUIDE 

Power Vent System

NOTE: Service must be performed by a qualified installer, service agency, or your gas supplier.

BEFORE TROUBLESHOOTING THE UNIT:
1. Confirm there is power to the unit (fireplace). 

2. Confirm there is gas to the unit (fireplace). 

3. The igniter module in the fireplace is equipped with a device that can put the unit into a lockout state. Follow the steps in the chart below to reset the 

control: Turn the ON/REMOTE/OFF switch to the OFF position, or turn the remote to the OFF position. 

4. If this is the first time that the unit has been fired, check the wiring of the unit against the wiring diagram before commencing troubleshooting.

Содержание Montebello MDLX40IN-PV

Страница 1: ...r death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR...

Страница 2: ...rifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Gas Controls Control Compartment Access 8 Appliance Operation 8 Purge Cycle 8 Remote Control System 9 Lighting the Appliance 11 P...

Страница 3: ...atures lev es voir Page 5 Lisez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una mall...

Страница 4: ...s enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour...

Страница 5: ...du r cepteur mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque du r cepteur mural qui contr le le foyer Figure A Choisissez la langue qu...

Страница 6: ...refully supervised when they are in the same area as a hot termination APPLIANCE OPERATION NOTICES Do not operate appliance with the glass front removed cracked or broken These fireplaces are vented g...

Страница 7: ...nnections are provided on the front of the gas control valve identified IN for the inlet and OUT for the manifold side see Figure 2 on Page 9 The control valve has a 3 8 in 10 mm NPT thread inlet and...

Страница 8: ...n and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjust...

Страница 9: ...to the gas valve coil and the appliance main burner turns on A single beep from the receiver will confirm reception of the command Turn OFF the Appliance Press the ON OFF Key on the transmitter The tr...

Страница 10: ...or transmitter are low or depleted the appliance can be turned on manually by sliding the ON REMOTE OFF slider switch to the ON position This will bypass the remote control feature of the system and t...

Страница 11: ...lot will light 4 Burner should light after a few seconds To turn ON the appliance with the remote transmitter 1 Manually slide the ON REMOTE OFF switch to the REMOTE position then press the ON OFF key...

Страница 12: ...vinegar water Gas fireplace stove glass cleaner Inspect Glass Gasket Visually inspect the gasket on the backside of the glass enclosure panels The gasket surface must be clean free of irregularities...

Страница 13: ...ass Enclosure Panel Top Flange Glass Door Frame Assembly Glass Door Latch 2 Latch Screws Firebox Floor Glass Door Assembly WARNING When reinstalling the glass door the door latch screws must be secure...

Страница 14: ...cal to encourage outstanding flame appearance and prevent sooting When positioned properly as shown twigs will be positioned between flame peaks and will not impinge any flames WARNING DO NOT attempt...

Страница 15: ...Hole At Bottom Of Log 5 Over The Pin On Log 2 Engage Log 7 With The Pin On Log 4 6 5 7 2 4 MDLX40IN PV MDLX45IN PV Log Placement Align Two Holes At Bottom Of Log 1 Over The Pins On The Gas Burner 1 F...

Страница 16: ...terior surfaces adjacent to the vent termination Sooting is caused by incomplete combustionintheflamesandlackofcombustion air entering the air shutter opening To achieve a warm yellow orange flame wit...

Страница 17: ...justment air shutter located on the lower venturi back or forward to increase or reduce the air shutter opening respectively Positiontheairshutterto the factory setting as shown in Table 8 Allow the b...

Страница 18: ...distributor LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike Suite 108 Nashville TN 37210 visit us at www LennoxHearthProducts com 1 800 655 2008 PRODUCT REFERENCE INFORMATION We recommend that you record th...

Страница 19: ...ts attach to the grate assembly without the use of hardware Cat No Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE Bag of Platinum Embers Table 9 Firebox A...

Страница 20: ...log Number Model Description H4805 BSK40 40 in Barrier Screen H4806 BSK45 45 in Barrier Screen Table 14 Barrier Screen Kits Catalog Number Model Description H5051 DASK LSM40IN 2 40 in Screen H5054 DAS...

Страница 21: ...actly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to lig...

Страница 22: ...it sur la portion sup rieure gauche de cette tiquette S il n y a pas d odeur de gaz passez l tape suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 A...

Страница 23: ...ortions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropri...

Страница 24: ...n immediately goes out Gas is not reaching the fireplace Check the gas supply and gas shutoff valves call a service technician if required Loose wires to the valve or ignition module Check the gas sup...

Страница 25: ...ve No Yes Check Position of Pilot Is Orifice Blocked No Replace Ignition Module No Does the Pilot Flame Cover the Flame Rod Is the Sensor Wire in Good Condition Is There Continuity to Ground from the...

Страница 26: ...7 2 H1169 2 11 Gasket Access Plate H1452 1 H1452 1 12 Gas Line Tubing H2283 1 H2284 1 13 Connector Male H2285 1 H2285 1 14 Orifice Natural Gas H7924 1 H8141 1 15 Bag of Glowing Embers 88L53 1 88L53 1...

Страница 27: ...EBELLO DLX POWER VENT DV GAS FIREPLACES MDLX40 45IN PV CARE AND OPERATION INSTRUCTIONS 27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 23 15 21 22 7 17 13 12 6 8 11 10 9 5 1 4 16 3 20 19 18 25 24 14 F...

Страница 28: ...ion Box 1 22 H7379 Diverter Front 1 23 H7380 Diverter Back 1 24 H7376 Wrapper Cover 1 25 H7381 Wire Mesh 1 24 18 19 17 16 15 14 8 25 22 23 21 1 4 20 7 5 2 6 3 Printed in U S A 2012 Lennox Hearth Produ...

Отзывы: