LENNOX HEARTH PRODUCTS • MONTEBELLO
®
DLX POWER VENT DV GAS FIREPLACES (MDLX40/45IN-PV) • CARE AND OPERATION INSTRUCTIONS
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Lighting the Appliance
To light electronic appliances refer to the
detailed lighting instructions found on
Page 21
of these instructions. Instructions
can also be found on the pull-out lighting
instruction labels attached to the gas
control valve.
POWER VENT OPERATION
Operating Instructions for
the Appliance
To turn ON the appliance with the receiver:
1. Manually slide the ON/REMOTE/OFF
switch to the ON position.
2. Blower should start immediately.
3. Igniter starts sparking and pilot will light.
4. Burner should light after a few seconds.
To turn ON the appliance with the
remote transmitter:
1. Manually slide the ON/REMOTE/OFF
switch to the REMOTE position, then
press the ON/OFF key on the transmitter.
2. Blower should start immediately.
3. Igniter starts sparking and pilot will light.
4. Burner should light after a few seconds.
To Turn OFF
1. Manually slide the ON/REMOTE/OFF
switch to the OFF position or press the
ON/OFF key on the transmitter.
2. Burner and pilot should turn off
immediately.
3. Blower will continue to run for about
15 seconds, then the blower will stop.
16.17
(411 mm)
15.92
(404 mm)
10.00
(254 mm)
11.19
(284 mm)
13.50
(343 mm)
Top View
Front View
16.17
(411 mm)
15.92
(404 mm)
10.00
(254 mm)
11.19
(284 mm)
13.50
(343 mm)
Top View
Front View
Figure 8: Power Vent Termination Specifications
Front View
Top View
NOTE: Dimensions Are In Inches (mm)