Page 27
TABLE 13 Continued
Maximum Allowable Intake or Exhaust Vent Length in Feet
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined
total. Both Intake and Exhaust must be same pipe size.
NOTE - additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in
the total vent length calculation.
Concentric Termination at Elevation 0 - 2000 ft
No. 90°
Elbows
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
030 045 070 090 110 135
030
045
070 090 110 135
030
045
070 090 110 135
030
045
070 090 110 135
1
20
15
10
n/a n/a
n/a
73
58
42
22
n/a
105
105
89
54
n/a
121
121 114 114
70
2
15
10
n/a
68
53
37
17
100
100
84
49
116
116
109 109
65
3
10
n/a
63
48
32
12
95
95
79
44
111
111
104 104
60
4
n/a
58
43
27
n/a
90
90
74
39
106
106
99
99
55
5
53
38
22
85
85
69
34
101
101 94
94
50
6
48
33
17
80
80
64
29
96
96
89
89
45
7
43
28
12
75
75
59
24
91
91
84
84
40
8
38
23
n/a
70
70
54
19
86
86
79
79
35
9
33
18
65
65
49
14
81
81
74
74
30
10
28
13
60
60
44
n/a
76
76
69
69
25
Concentric Termination at Elevation 2001 - 10,000 ft
No. 90°
Elbows
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
030
045
070
090
110
135
030
045
070
090
110
135
030
045
070
090
110
135
1
73
30
15
n/a
n/a
105
96
53
38
n/a
121
121
114
114
70
2
68
25
10
100
91
48
33
116
116
109
109
65
3
63
20
n/a
95
86
43
28
111
111
104
104
60
4
58
15
90
81
38
23
106
106
99
99
55
5
53
10
85
76
33
18
101
101
94
94
50
6
48
n/a
80
71
38
13
96
96
89
89
45
7
43
75
66
23
n/a
91
91
84
84
40
8
38
70
61
18
86
86
79
79
35
9
33
65
56
13
81
81
74
74
30
10
28
60
51
n/a
76
76
69
69
25