INSTALL UNIT LEVEL OR, IF ON A SLOPE, MAINTAIN SLOPE TOLERANCE

OF 2 DEGREES (OR 2 INCHES PER 5 FEET [50 MM PER 1.5 M]) AWAY

FROM BUILDING STRUCTURE.

DETAIL A

DETAIL B

INSTALL UNIT AWAY

FROM WINDOWS

TWO 90  ELBOWS INSTALLED IN LINE SET

WILL REDUCE LINE SET VIBRATION

GROUND LEVEL

MOUNTING

SLAB

BUILDING

STRUCTURE

DISCHARGE AIR

FIGURE 3. Placement and Slab Mounting

Unit Placement 

See Unit Dimensions on page 3 for sizing mounting slab, 

platforms or supports. Refer to page 2 for mandatory in

-

stallation clearance requirements.

 CAUTION

In order to avoid injury, take proper precaution when 

lifting heavy objects..

POSITIONING CONSIDERATIONS 

Consider the following when positioning the unit: 
•   Some localities are adopting sound ordinances based 

on the unit's sound level registered from the adjacent 

property, not from the installation property. Install the 

unit as far as possible from the property line. 

•   When possible, do not install the unit directly outside 

a window. Glass has a very high level of sound trans

-

mission. For proper placement of unit in relation to a 

window see the provided illustration in figure 3, detail A.

PLACING UNIT ON SLAB

When installing unit at grade level, the top of the slab 

should be high enough above grade so that water from 

higher ground will not collect around the unit. The slab 

should have a slope tolerance as described in figure 3, 

detail B. 

ROOF MOUNTING

Install the unit a minimum of 6 inches (152 mm) above the 

roof surface to avoid ice build-up around the unit. Locate 

the unit above a load bearing wall or area of the roof that 

can adequately support the unit. Consult local codes for 

rooftop applications.
If unit coil cannot be mounted away from prevailing winter 

winds, a wind barrier should be constructed. Size barrier 

at least the same height and width as outdoor unit. Mount 

barrier 24 inches (610 mm) from the sides of the unit in the 

direction of prevailing winds. 

 NOTICE

Roof Damage!

This system contains both refrigerant and oil. Some 

rubber  roofing  material  may  absorb  oil,  causing  the 

rubber to swell. Bubbles in the rubber roofing material 

can cause leaks. Protect the roof surface to avoid 

exposure to refrigerant and oil during service and 

installation. Failure to follow this notice could result in 

damage to roof surface.

Содержание ML18XC2 Series

Страница 1: ...cal Unit Parts Arrangement 5 Operating Gauge Set and Service Valves 5 Unit Placement 7 Removing and Installing Louvered Panels 8 New or Replacement Line Set 9 Brazing Connections 11 Flushing Line Set...

Страница 2: ...the remaining two sides may be A clearance of 24 in must be maintained between two units 48 in 1219 mm clearance required on top of unit Model Number Identification Nominal Cooling Capacity 024 2 ton...

Страница 3: ...NNECTION 6 3 8 162 TOP VIEW BASE SECTION COMPRESSOR COIL DRAIN OUTLETS Around perimeter of base OPTIONAL UNIT STAND OFF KIT 4 Field Installed 111 4 3 8 4 3 8 4 3 8 4 3 8 6 3 8 162 111 111 111 111 4 3...

Страница 4: ...t ampacity MCA 14 6 20 2 26 2 32 2 Compressor Rated load amps 10 9 15 4 19 9 23 7 Locked rotor amps 61 92 127 151 Power factor 0 97 0 94 0 93 0 92 Outdoor Fan Motor Full load amps 1 1 1 4 2 6 Locked R...

Страница 5: ...ugly over the cap before tightening TABLE 1 Torque Requirements Parts Recommended Torque Service valve cap 8 ft lb 11 NM Sheet metal screws 16 ft lb 2 NM Machine screws 10 28 ft lb 3 NM Compressor bol...

Страница 6: ...7 8 9 10 11 12 1 12 TURN To Access Service Port A service port cap protects the service port core from contamination and serves as the primary leak seal 1 Remove service port cap with an appropriately...

Страница 7: ...ent of unit in relation to a window see the provided illustration in figure 3 detail A PLACING UNIT ON SLAB When installing unit at grade level the top of the slab should be high enough above grade so...

Страница 8: ...ons that may cause panels to be blown around and battered WARNING REMOVAL STEP 1 INSERT PANEL UNDER UNIT TOP CAP LIP AND LIFT SLIGHTLY TO CLEAR SIDE LIP OF PANEL FROM BASE STEP 2 PANEL INSTALLATION TO...

Страница 9: ...ge in the system No need to add oil in system with 20 pounds of refrigerant or less For systems over 20 pounds add one ounce for every five pounds of refrigerant Recommended topping off POE oils are M...

Страница 10: ...be used if line set is to be installed on exterior of outside wall PVC PIPE FIBERGLASS INSULATION CAULK OUTSIDE WALL VAPOR LINE WRAPPED WITH ARMAFLEX LIQUID LINE OUTSIDE WALL LIQUID LINE VAPOR LINE WO...

Страница 11: ...dous to your health Avoid breathing vapors or fumes from brazing operations Perform operations only in well ventilated areas Wear gloves and protective goggles or face shield to protect against burns...

Страница 12: ...SERVICE VALVE Flow regulated nitrogen at 1 to 2 psig through the low side refrigeration gauge set into the liquid line service port valve and out of the suction vapor line service port valve CUT AND D...

Страница 13: ...tions for the next step in preparing the unit WHEN BRAZING LINE SET TO SERVICE VALVES POINT FLAME AWAY FROM SERVICE VALVE PREPARATION FOR NEXT STEP 7 WARNING 1 FIRE PERSONAL INJURY OR PROPERTY DAMAGE...

Страница 14: ...ISTING INDOOR UNIT GAUGE MANIFOLD INVERTED CYLINDER CONTAINS CLEAN HCFC22 TO BE USED FOR FLUSHING LIQUID LINE SERVICE VALVE INLET DISCHARGE TANK RETURN CLOSED OPENED RECOVERY CYLINDER RECOVERY MACHINE...

Страница 15: ...reads and expose surface of the Teflon ring with refrigerantoil E Attach the liquid line assembly to the expansion valve Finger tighten and use an appropriately sized wrench to turn an additional 1 2...

Страница 16: ...losed connect the cylinder of HFC 410A refrigerant to the center port of the manifold gauge set Open the valve on the HFC 410A cylinder vapor only B Open the high pressure side of the manifold to allo...

Страница 17: ...r unit until the absolute pressure does not rise above 500 microns 29 9 inches of mercury within a 20 minute period after shutting off the vacuum pump and closing the manifold gauge valves F When the...

Страница 18: ...to unit nameplate for minimum circuit ampacity and maximum overcurrent protection size 24VAC TRANSFORMER Use the transformer provided with the furnace or air han dler for low voltage control power 24...

Страница 19: ...Y1 Y2 C K1 S4 R C R W2 W1 Y2 C BLACK BLUE YELLOW Y Y1 G G W INDOOR UNIT TB1 THERMOSTAT A2 EL196E ML180E ML193E EL180E EL195E ML196E R W2 W1 G C BLACK BLUE YELLOW Y1 Y2 INDOOR UNIT A92 TB1 DS O W914 W9...

Страница 20: ...to shut off compressor operation The auto reset switch closes when the compressor cas ing temperature falls to 151 187 F 66 C 86 C and the compressor is re energized This single pole single throw SPS...

Страница 21: ...sure no obstructions restrict airflow to the outdoor unit Grass clippings leaves or shrubs crowding the unit can cause the unit to work harder and use more energy Keep shrubbery trimmed away from the...

Страница 22: ...all factory and field installed wiring for loose connections 3 After evacuation is complete open the liquid line and suction line service valves to release the refrigerant charge contained in outdoor...

Страница 23: ...pply Air Temperature Ambient Temperature Return Air Temperature System Refrigerant Charge Refer to manufacturer s information on unit or installation instructions for required subcooling and approach...

Отзывы: