Page 19

NOTE-

IF ANY WIRE IN THIS APPLIANCE IS REPLACED,IT

MUST BE REPLACED WITH WIRE OF LIKE SIZE,

RATING, INSULATION THICKNESS, AND TERMINATION.

EQUIPMENT

GROUND

WARNING-

ELECTRIC SHOCK HAZARD,CAN CAUSE INJURY

OR DEATH.UNIT MUST BE GROUNDED IN ACCORDANCE

WITH NATIONAL AND LOCAL CODES.

DENOTES OPTIONAL COMPONENTS

LINE VOLTAGE FIELD INSTALLED

CLASS II VOLTAGE FIELD WIRING

  

Supersedes

Litho U.S.A.

C

GROUND

LUG

K1

COMPRESSOR

CONTACTOR

S87 LOW

PRESSURE

SWITCH

R

S

C

B1

COMPRESSOR

S4

HIGH

PRESSURE

SWITCH

D

R

H

Y2

Y1

C

W2

W1

B1

RED

3

RED

L34

LENNOX

REMOVE JUMPER FOR TWO STAGE COOL

4

5

6

7

COMPRESSOR

CONTACTOR

BLACK

L2

L1

2

2

ON A92 CUT ONBOARD W914 JUMPER FROM D5

TO R, WHEN HUMIDITY CONTROL IS USED

ON A92 DO NOT CUT ONBOARD W951 JUMPER

FROM R TO O. IT IS USED FOR APPLICATIONS

FOR CONDENSING UNITS

FOR CONDENSING UNIT APPLICATIONS USE R TO

O JUMPER. REMOVE IN HEAT PUMP APPLICATIONS

REMOVE DS TO Y1 JUMPER WHEN HUMIDITY

CONTROL IS USED
WHEN TWO STAGE THERMOSTAT IS USED, CONNECT

SECOND STAGE HEAT BULB TO TERMINAL "W2", AND

REMOVE JUMPER BETWEEN "R" AND "W2"

L34 SOLENOID IS LOCATED IN COMPRESSOR.

COIL IS 24VDC. DO NOT CONNECT 24VAC

TO COIL TERMINALS

S11 IS OPTIONAL LOW AMBIENT SWITCH

NOTE-MINIMUM TRANSFORMER REQUIRED IN

INDOOR UNIT-40 VA

Y1
Y2

C

K1

S4

R

C

R

W2

W1

Y2

C

BLACK

BLUE

YELLOW

Y

Y1

G

G

W

INDOOR

UNIT

TB1

THERMOSTAT

A2

EL196E  ML180E ML193E

EL180E EL195E ML196E

R

W2

W1

G

C

BLACK

BLUE

YELLOW

Y1
Y2

INDOOR

UNIT A92

TB1

DS

O

W914

W951

8

9

10

11

10

3

4

5

6

K1-1

G

A2

COOLING -

CONDENSING

2011

START

CAPACITOR

K31

POTENTIAL

RELAY

(OPTIONAL)

F

C

H

C12

DUAL

CAPACITOR

ORANGE-RUN

BLACK-COMMON
PURPLE-

CAPACITOR

B4

OUTDOOR FAN

(LEADED)

THERMOSTAT

2

4

3

1

5

BLACK

L34

F

C

H

COMPRESSOR

C12 DUAL

CAPACITOR

YELLOW

2

1

5

RED

K31

C7

230/60/1

12 OPTIONAL HARD START KIT MAY BE REQUIRED

ON APPLICATIONS WHERE VOLTAGES ARE LESS THAN

230 VOLT KIT ICLUDES K31 AND C7 WITH ALL NECESSARY

WIRING.

R

C

S

S40

CRANKCASE THERMOSTAT

CRANKCASE HEATER

13

RED

BLACK

D

R

Y2

Y1

G

C

W2

W1

R

W2

W1

G

C

BLACK

BLUE

YELLOW

Y1

Y2

INDOOR

UNIT

TB1

DS

O

W3

4

7

8

9

H

THERMOSTAT

A2

PURPLE

OR BROWN

ORANGE

B4

FAN MOTOR

(LEADED)

BLUE

D4

10

BLUE

YELLOW

S11

S87

11

HR1

13 S40 AND HRI ARE USED ON 048 AND 060 UNITS ONLY

2

1

NOTE-

FOR USE WITH COPPER CONDUCTORS

ONLY. REFER TO UNIT RATING PLATE

FOR MINIMUM CIRCUIT AMPACITY AND

MAXIMUM OVERCURRENT PROTECTION SIZE

REFER TO COMPRESSOR IN UNIT FOR

ACTUAL TERMINAL ARRANGEMENT

SLP99V SL297V SL280V ML296V

ML180V EL280E EL 296E SLP99

12

CBA25UH, CBA27UHE

& CBA38MV

ML18XC2-024

ML18XC2-036

CUT SIZE: 6-1/2" WIDE 6" TALL

ML18XC2-048

ML18XC2-060

COMPRESSOR

CONTACTOR

L1

K1-1

EQUIPMENT

GROUND

L2

RED

RED

ML18XC2-024

ML18XC2-036

ML18XC2-048

EC MOTOR CONNECTION

(ML18XC2-060)

FIGURE 12. Typical Wiring Diagram

Содержание ML18XC2 Series

Страница 1: ...cal Unit Parts Arrangement 5 Operating Gauge Set and Service Valves 5 Unit Placement 7 Removing and Installing Louvered Panels 8 New or Replacement Line Set 9 Brazing Connections 11 Flushing Line Set...

Страница 2: ...the remaining two sides may be A clearance of 24 in must be maintained between two units 48 in 1219 mm clearance required on top of unit Model Number Identification Nominal Cooling Capacity 024 2 ton...

Страница 3: ...NNECTION 6 3 8 162 TOP VIEW BASE SECTION COMPRESSOR COIL DRAIN OUTLETS Around perimeter of base OPTIONAL UNIT STAND OFF KIT 4 Field Installed 111 4 3 8 4 3 8 4 3 8 4 3 8 6 3 8 162 111 111 111 111 4 3...

Страница 4: ...t ampacity MCA 14 6 20 2 26 2 32 2 Compressor Rated load amps 10 9 15 4 19 9 23 7 Locked rotor amps 61 92 127 151 Power factor 0 97 0 94 0 93 0 92 Outdoor Fan Motor Full load amps 1 1 1 4 2 6 Locked R...

Страница 5: ...ugly over the cap before tightening TABLE 1 Torque Requirements Parts Recommended Torque Service valve cap 8 ft lb 11 NM Sheet metal screws 16 ft lb 2 NM Machine screws 10 28 ft lb 3 NM Compressor bol...

Страница 6: ...7 8 9 10 11 12 1 12 TURN To Access Service Port A service port cap protects the service port core from contamination and serves as the primary leak seal 1 Remove service port cap with an appropriately...

Страница 7: ...ent of unit in relation to a window see the provided illustration in figure 3 detail A PLACING UNIT ON SLAB When installing unit at grade level the top of the slab should be high enough above grade so...

Страница 8: ...ons that may cause panels to be blown around and battered WARNING REMOVAL STEP 1 INSERT PANEL UNDER UNIT TOP CAP LIP AND LIFT SLIGHTLY TO CLEAR SIDE LIP OF PANEL FROM BASE STEP 2 PANEL INSTALLATION TO...

Страница 9: ...ge in the system No need to add oil in system with 20 pounds of refrigerant or less For systems over 20 pounds add one ounce for every five pounds of refrigerant Recommended topping off POE oils are M...

Страница 10: ...be used if line set is to be installed on exterior of outside wall PVC PIPE FIBERGLASS INSULATION CAULK OUTSIDE WALL VAPOR LINE WRAPPED WITH ARMAFLEX LIQUID LINE OUTSIDE WALL LIQUID LINE VAPOR LINE WO...

Страница 11: ...dous to your health Avoid breathing vapors or fumes from brazing operations Perform operations only in well ventilated areas Wear gloves and protective goggles or face shield to protect against burns...

Страница 12: ...SERVICE VALVE Flow regulated nitrogen at 1 to 2 psig through the low side refrigeration gauge set into the liquid line service port valve and out of the suction vapor line service port valve CUT AND D...

Страница 13: ...tions for the next step in preparing the unit WHEN BRAZING LINE SET TO SERVICE VALVES POINT FLAME AWAY FROM SERVICE VALVE PREPARATION FOR NEXT STEP 7 WARNING 1 FIRE PERSONAL INJURY OR PROPERTY DAMAGE...

Страница 14: ...ISTING INDOOR UNIT GAUGE MANIFOLD INVERTED CYLINDER CONTAINS CLEAN HCFC22 TO BE USED FOR FLUSHING LIQUID LINE SERVICE VALVE INLET DISCHARGE TANK RETURN CLOSED OPENED RECOVERY CYLINDER RECOVERY MACHINE...

Страница 15: ...reads and expose surface of the Teflon ring with refrigerantoil E Attach the liquid line assembly to the expansion valve Finger tighten and use an appropriately sized wrench to turn an additional 1 2...

Страница 16: ...losed connect the cylinder of HFC 410A refrigerant to the center port of the manifold gauge set Open the valve on the HFC 410A cylinder vapor only B Open the high pressure side of the manifold to allo...

Страница 17: ...r unit until the absolute pressure does not rise above 500 microns 29 9 inches of mercury within a 20 minute period after shutting off the vacuum pump and closing the manifold gauge valves F When the...

Страница 18: ...to unit nameplate for minimum circuit ampacity and maximum overcurrent protection size 24VAC TRANSFORMER Use the transformer provided with the furnace or air han dler for low voltage control power 24...

Страница 19: ...Y1 Y2 C K1 S4 R C R W2 W1 Y2 C BLACK BLUE YELLOW Y Y1 G G W INDOOR UNIT TB1 THERMOSTAT A2 EL196E ML180E ML193E EL180E EL195E ML196E R W2 W1 G C BLACK BLUE YELLOW Y1 Y2 INDOOR UNIT A92 TB1 DS O W914 W9...

Страница 20: ...to shut off compressor operation The auto reset switch closes when the compressor cas ing temperature falls to 151 187 F 66 C 86 C and the compressor is re energized This single pole single throw SPS...

Страница 21: ...sure no obstructions restrict airflow to the outdoor unit Grass clippings leaves or shrubs crowding the unit can cause the unit to work harder and use more energy Keep shrubbery trimmed away from the...

Страница 22: ...all factory and field installed wiring for loose connections 3 After evacuation is complete open the liquid line and suction line service valves to release the refrigerant charge contained in outdoor...

Страница 23: ...pply Air Temperature Ambient Temperature Return Air Temperature System Refrigerant Charge Refer to manufacturer s information on unit or installation instructions for required subcooling and approach...

Отзывы: