36
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
GAS CONVERSION KITS
Natural Gas to Propane Gas
Conversion Kits
Fireplace
Model No.
Cat. No.
(model)
MPD35ST/PF-NM
millivolt
H3360
(GCK35STMPN)
MPD35ST/PF-NE
electronic
H336
(GCK35STENP)
Table 12
Propane Gas to Natural Gas
Conversion Kits
Fireplace
Model No.
Cat. No.
(model)
MPD35ST/PF-PM
millivolt
H204
GCK-MPD40MPN
MPD35ST/PF-PE
electronic
26M65
(GCK-MP40EPN)
Table 13
Gas conversion kits are available to adapt the
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete the
task including labeling that must be affixed to
ensure safe operation.
Kit part numbers are listed here and the following
steps detail the conversion procedure.
Step . Turn off the gas supply to the appliance.
a. Open the control compartment access
panel, by actuating the spring-loaded
magnetic catches securing the panel,
gently depressing the outer top corners
of the panel until the catches "pop" the
panel free and allowing it to swing out
and down to open.
b. Remove the bottom control compart-
ment access panel by compressing the
spring-loaded hinge pin on the left side
until it disengages from the left cabinet
panel hole. Pull the panel away from the
fireplace. See
Figure 49
on
Page 27
.
IMPORTANT - CANADA ONLY:
The conversion shall be car-
ried out in accordance with the
requirements of the provincial
authorities having jurisdiction
and in accordance with the
requirements of the CAN-
B49. And B49.2 Installation
code.
WARNING: This conversion kit
shall be installed by a quali-
fied service agency in accor-
dance with the manufacturer's
instructions and all applicable
codes and requirements of the
authorized having jurisdiction. If
the information in these instruc-
tions is not followed exactly, a
fire, explosion or production of
carbon monoxide may result
causing property damage, per-
sonal injury or loss of life. The
installation is not proper and
complete until the operation
of the converted appliance is
checked as specified in the owner
instructions supplied with the
kit. The qualified service agency
performing this installation
assumes responsibility for this
conversion.
ATTENTION - LE CANADA SEULE-
MENT: La conversion devra être
effectuée conformément aux
recommandations des autorités
provinciales ayant juridiction et
conformément aux exigences
du code d'installation CAN-
B49. Et.2.
AVERTISSEMENT: Cet Équipement
de conversion sera installÉ par une
agence qualifiÉe de service confor-
mÉment aux instructions du fabri-
cant et toutes exigences et codes
applicables de l’autorisÉs avoir la
juridiction. Si l’information dans
cette Instruction n’est pas suivie
exactement, un feu, explosion ou
production de protoxyde de car-
bone peut rÉsulter le dommages
causer de propriÉtÉ, perte ou bles-
sure personnelle de vie. L’agence
qualifiÉe de service est espon-
sable de l’installation propre de
cet Équipment. L’installation n’est
pas propre et complÉte jusqu’à
l’opÉration de l’appareil converti
est chÉque suivant les critères
Établis dans les instructions de
propriÉtaire provisionnÉes avec
l’Équipement.