NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Step 5.
WIRING - OPTIONAL FORCED AIR
BLOWER KIT
FBK-00, FBK-200 and FBK-250 Kits
(See
Figure 47
for wiring) -
An electrical receptacle is provided for the instal-
lation of the FBK-00, FBK-200 and FBK-250
forced air blower kits. Electrical power must be
connected to this receptacle in order to operate
these blowers. Install the blower kits according
to the installation instructions provided with the
kits. See
Figure 13A on Page 9 and Figure 13B
on page 10
showing where blower should be
located on unit.
Figure 46
Outlet Receptacle
Junction Box
Field-provided Metal Junction Box
Cover Plate With Screw
View Of Left
Bottom Corner Of Unit
Receptacle, Junction Box
and Cover Plate Installation
Fireplace
Side
Junction Box
knock-out (2
places each side)
Valve Access Side
Latching magnet
not shown
Press snap
bushing into the
knock-out for
control switch
wires.
Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-00, FBK-200 & FBK-250 Kits
Schematic Representation Only
Relay Module C/W FBK-250 only. Plug blower
into J-Box receptacle for FBK-100 or FBK-200
application. See View A for J-Box wiring.
Optional Blower
*OFF/ON Switch
(Integral with
Gas Valve)
Honeywell
Electronic
Gas
Valve
120 VAC
Primary
Secondary
Optional Control Switch
Junction Box
Pilot Burner
Assembly
BL
BL
Field Wired
Factory
Wired
BK = BLACK BL = BLUE
R = RED W = WHITE
G = GREEN
BK
W
BK
BK
BL
R
GROUND
24 V
Transformer
View A
J-Box Wiring when
using unit mounted
relay module.
BK
W
G
CA
V
02
1
Igniter
Connector
* Leave the OFF/ON switch, which is
integral with the gas valve, in the ON
position.
**
Optional Control Switches
: Wall
Switch, Wall Thermostat or Remote
Control Receiver.
Notes:
1. If any of the original wire as supplied
must be replaced, use Type AWM 105°C
- 18 gage wire ONLY.
2. 120 VAC, 60 Hz - Less than 3 Amps.
Caution: label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
Junction Box
Tab Intact
Tab
Broken
Plug blower
into this
receptacle
n
e
e
r
G
-
d
n
u
o
r
G
* Wall-mounted
ON/ OFF Blower
Switch or Variable
Speed Control Switch.
Blower
Ground
e
ti
h
W
-
l
a
rt
u
e
N
120 VAC - Black
Green
Ground
Screw
White
Green
Neutral
Side of
Receptacle
Hot
Side of
Receptacle
Red
Black
J-BOX WIRING FOR
WALL SWITCH
BLOWER CONTROL
Figure 47
CAUTION: Remove the carton sup-
port from the control compartment
before operating the appliance.
CAUTION: Ground supply lead must
be connected to the wire attached
to the green ground screw located
on the outlet box. See
Figure 47
.
Failure to do so will result in a
potential safety hazard. The appli-
ance must be electrically grounded
in accordance with local codes or,
in the absence of local codes, the
National Electrical Code, ANSI/
NFPA 70-latest edition. (In Canada,
the current CSA C22- Canadian
Electrical Code).
CAUTION: Ensure that wires are
positioned away from hot surfaces
and sharp edges.
CAUTION: Do not connect the
optional wall switch to a 20 Volt
AC power supply.