This suggestion is provided in the interest of 
better operation. If the terminations are located 
too close to each other, smoke may migrate 
from one fl ue into the other.

FTF8 CHIMNEY COMPONENT
CALCULATIONS

The minimum installed height of the completed 
fi replace system is 15' 0" for indoor installa-
tions and 7' 9" for outdoor installations.  The 
maximum height is 60' 0."

MULTIPLE TERMINATIONS

If more than one termination is located in the 
same chase or within the same general prox-
imity, we suggest they should be separated 
in distance at least 24" horizontally from fl ue 
center to fl ue center and stacked or staggered 
vertically at least 18" apart, from the termination 
of one smoke exit to the termination of another 
smoke exit (

Figure 44

).

Note:

 It is recommended that all exterior ex-

posed metal fi replace components; such as 
terminations, fl ashings, storm collars and/or 
fl ue be painted with a premium quality, high 
temperature, rust preventative paint designed 
for metal. This is especially important when 
installations are made in abnormally adverse 
or corrosive environments; such as near lakes, 
oceans or in areas with consistently high 
humidity conditions. Consult the paint manu-
facturers instructions for proper preparation 
and application.

TEN FOOT RULE SUMMARY

The minimum chimney height above the roof 
and/or to adjacent walls and buildings is speci-
fi ed by all major building codes.

If the horizontal distance from the peak of the 
roof is less then 10', the top of the chimney must 
be at least 2' above the peak of the roof.

If the horizontal distance from the chimney 
edge to the peak of the roof is more than 10' a 
chimney height reference point is established 
on the roof surface 10' horizontally from the 
chimney edge. The top of the chimney must 
be at least 2' above this reference point. In all 
cases, the chimney cannot be less then 3' above 
the roof at the edge of the chimney.

The 2' in 10' rule is necessary in the interest 
of safety but does not ensure smoke-free op-
eration. Trees, buildings, adjoining roof lines, 
adverse wind conditions, etc., may require a 
taller chimney should the fi replace not draft 
properly (

refer to

 Figure 43

).

Less Than 10'

3'

Min

2' Min.

10'

3'

Min

CTD

18"

18"

24"

24"

CTDT

CTDT

Figure 43

Figure 44

To determine the number of chimney sections 
and chimney components required, follow 
these steps:

1.

 Determine total vertical height of the fi replace 

installation. This dimension is the distance from 
the surface the fi replace sets on to the point 
where smoke exits from the termination.

2.

 Determine the number of chimney compo-

nents required, except chimney sections. This 
would include fi restop spacers, stabilizers, roof 
fl ashing, etc.

3.

 The effective heights of the components 

are:

The Fireplace 

=   42-1/4"

FTF8-12 = 

10-1/4"

FTF8-18 = 

16-1/4"

FTF8-36 = 

34-1/4"

FTF8-48 = 

46-1/4"

** FTF8-CTD Termination  =   4"

FTF8-CT1 Termination 

=   12" to 18"

FTF8-CT2 Termination 

=  15" to 23"

** FTF8-CTDT Termination =  12" to 18"

FTF8-CTDTM Termination  =  4"

FTF8-S4 Stabilizer * 

=  3"*

* Required for every 30' of vertical chimney 
and/or 10' of offset chimney.

**FTF8-CT1 and FTF8-CTDT Terminations 
are approved for indoor fi replace installa-
tions only.

4.

 Determine amount of chimney height required 

by subtracting total combined height of all pre-
selected components (fi replace and chimney 
components from total desired height).

Reference Vertical Elevation Chart and determine 
the number of chimney sections (quantity and 
length) required.

SPECIAL OFFSET INSTRUCTIONS

To clear any overhead obstructions, you may 
offset your chimney system using Security 
Chimneys 30° offset and return elbows. Use 
two elbows - an offset elbow to initiate the 
offset and a return elbow to terminate it. A 30° 
offset elbow, angling in any direction, may be 
the fi rst component used off the top of the 
fi replace fl ue collar.

Содержание Merit Plus MP-420D

Страница 1: ...EQUIPPED TO BE READILY IN STALLED OUTDOORS IF INSTALLED INDOORS YOU MUST INSTALL THE COMBUSTION AIR COVER PROVIDED WITH THE INSTALLATION KIT OR PURCHASE THE OPTIONAL OUTSIDE AIR KIT GATE OAKG OD SEE...

Страница 2: ...tate and national codes and regulations 3 ThisfireplacemustbeinstalledwithSecurity Chimneys FTF8 8 203mm inside diam eter Chimney System only This fireplace is intendedforindoororoutdoorinstallations...

Страница 3: ...always maintain minimum clearances to combustible materials and do not violate any specific installation requirements These fireplaces have been tested and listed by OMNI Test Laboratories Inc Report...

Страница 4: ...materials Outdoor installations less than 15 height require chimney clearance of 2 air space to insulation and construction materials In Canada the chimney and fireplace outer wrapper require a minimu...

Страница 5: ...kept within the shaded areas illustrated in Figure 7 CLEARANCES Minimum clearance to combustibles for the appliance is as follows sides and back 1 25 mm floor 0 0mm adjacentwall 12 305 mm ceiling 37 1...

Страница 6: ...t If you plan to raise the fireplace and hearth extension build the platform assembly then position fireplace and hearth extension on top Secure the platform to the floor to prevent possible shifting...

Страница 7: ...the outside air kit is NOT installed you must install the Outside Air Cover provided with the instructions kit b IfanoutsideairkitISinstalled theOutside Air Kit Gate must be installed see Page 23 of o...

Страница 8: ...ons Outside Air Kit Installation provided These appliances are equipped with a com bustion air inlet collar so that it is possible to duct combustion air from the outdoors to the firebox To accomplish...

Страница 9: ...g Materials if any Rough Framing Face Unfinished Shown Combustion Air Kit Optional Framing Dimensions A 46 1 2 1181 mm B1 43 1 2 1105 mm B2 60 1 2 1537 mm C 33 828 mm D 17 1 2 445 mm E 76 1 4 1937 mm...

Страница 10: ...ions must not interfere with circulating grillwork Figure 19 Figure 20 A B Ceiling Framing C D Roof Framing Framing Dimensions for Ceiling Inches millimeters Flue Type A B FTF8 Vertical USA 14 1 2 368...

Страница 11: ...les espaceurs du dessus du foyer voir le sch ma 13 ne peuvent tre retir es ou modifi es vous ne pouvez pas entaillez le colombage pour ajuster autour ou tre install plus bas que les espaceurs Le colom...

Страница 12: ...and outer wrapper require a minimum 2 air space to insulation and construction materials Reference Figures 19 20 and charts Framing DimensionsforCeilingandRoof whichspecify minimum ceiling and roof di...

Страница 13: ...e the building must be con structed with galvalume outer sections only Theappropriatemodeldesignationsarelocated in the back of this manual F8FS30 Firestop Spacer FTF8 S4 Stabilizer 1 Min Air Space 30...

Страница 14: ...as noted in Step 4 Step 6 Select the proper Security Chimneys roof flashing based on pitch of roof Use chart below for selection Figure 37 Note Do not caulk or seal the ventilating open ings or seal t...

Страница 15: ...chimney must be at least 2 above this reference point In all cases thechimneycannotbelessthen3 above the roof at the edge of the chimney The 2 in 10 rule is necessary in the interest of safety but doe...

Страница 16: ...36 48 11 0 11 1 0 0 0 17 1 5 0 1 0 0 21 1 9 2 0 0 0 27 2 3 1 1 0 0 35 2 11 0 0 1 0 47 3 11 0 0 0 1 51 4 3 0 1 1 0 57 4 9 1 0 0 1 63 5 3 0 1 0 1 67 5 7 2 0 0 1 73 6 1 1 1 0 1 81 6 9 0 0 1 1 93 7 9 0 0...

Страница 17: ...the Straight Up In stallation Instructions for cutting and framing ceiling and roof openings Note See Framing and Dimension Chart for the sizes of the ceiling and roof openings The size of the roof op...

Страница 18: ...ilizer Considerthiswhen determining the need for a stabilizer Note Do not apply excessive pressure to any subsequent chimney section following return elbow assembly when installing Ensure that each su...

Страница 19: ...c tions are placed lower than 18 inches from the fireplace opening These fireplaces have been marked with a maximum rating of 26 000 BTU to assure that homeowners do not exceed the allowable limits fo...

Страница 20: ...ux non combustibles il se pourrait qu il n y ait pas suffisament de d gagement pour installer les portes de verre de votre choix Assurez d avoir un d gagmet suf fisant tout moment afin de ne pasinterf...

Страница 21: ...es 416 x 1 Answer TheminimumrequiredthicknessoftheMicore160is 417 there fore round up to nearest standard thickness available which is 1 2 Using the r formula Note To convert inches to millimeters div...

Страница 22: ...ormal wall decor with elaborate mantels to rustic wood paneling or warm brick facings Only noncombustible materials like stone tile brick etc may overlap the black front facing Do not extend these mat...

Страница 23: ...ith fireplace Shownhereforre placement purposes only Locking Band 63L60 FLB Ref Form 750 080M Spark Arrester 63L57 FSA 2 Ref Form 750 198M INSTALLATION COMPONENTS The following items are available for...

Страница 24: ...n For open top shrouds 96L20 FTF8 CTT Ref Form 750 077M Chimney Pack conventional Convenience Pack Residential 63L70 FTF8 CP7 Contains 3 FTF8 36 1 F8FS 1 F8F6 1 FTF8 CTD 7 P C 8 F T F R O I R E P U S...

Отзывы: