18
STEP 4
- Calculate superheat value on suction valves(According to form )
Measured Suction Line Pressure = _______ PSIG
STEP 5
- Calculate subcooling value on liquid valves(According to form )
Measured Suction Line Temp. = ________ºF
Calculate superheat value = ________ºF
Measured liquid Line Pressure = _______ PSIG
Measured liquid Line Temp = ________ºF
Calculate subcooling value = ________ºF
8
10
12
14
16
18
20
22
40
101
97
93
89
86
82
78
75
42
105 101
97
93
89
86
82
78
44
110 105 101
97
93
89
86
82
46
114 110 105 101
97
93
89
86
48
118 114 110 105 101
97
93
89
50
123 118 114 110 105 101
97
93
52
128 123 118 114 110 105 101
97
54
133 128 123 118 114 110 105 101
56
138 133 128 123 118 114 110 105
58
143 138 133 128 123 118 114 110
60
148 143 138 133 128 123 118 114
62
153 148 143 138 133 128 123 118
64
159 153 148 143 138 133 128 123
66
164 159 153 148 143 138 133 128
68
170 164 159 153 148 143 138 133
70
176 170 164 159 153 148 143 138
72
182 176 170 164 159 153 148 143
R-410A REFRIGERAN CHART
FINAL SUPERHEAT(
℉
)
SUCTION GAGE PRESSURE (PSI)
SUCTION
TEMP
(
℉
)
6
7
8
9
10
11
12
13
55
173 176 179 182 185 188 191 195
60
188 191 195 198 201 204 208 211
65
204 208 211 215 218 221 225 229
70
221 225 229 232 236 239 243 247
75
239 243 247 251 255 259 262 266
80
259 262 266 270 275 279 283 287
85
279 283 287 291 295 300 304 309
90
300 304 309 313 318 322 327 331
95
322 327 331 336 341 346 351 355
100
346 351 355 360 365 370 376 381
105
370 376 381 386 391 397 402 407
110
397 402 407 413 418 424 430 435
115
424 430 435 441 447 453 459 465
120
453 459 465 471 477 483 489 496
125
483 489 496 502 508 515 521 528
R-410A REFRIGERAN CHART
FINALSUBCOOLING
(℉)
LIQUID GAGE PRESSURE (PSI)
SUCTION
TEMP
(℉)
107℉
107℉
Note: If calculated subcooling value is lower than the design
subcooling value, please add refrigerant. Repeat the steps above.
Note:Make sure the superheat value of suction valve
should be above 12ºF, if the value is lower than this,
indoor TXV should be adjusted.If the temperature is
higher than 18ºF, we suggest to adjust indoor TXV.
Repeat the steps above.
(If to adjust TXV ,steps of
adjustment are shown on
separate sheet , and
repeat this step.)
Model
Design subcooling
24
36
48
60
10ºF
10ºF
8ºF
7ºF