Page 58
XP17
STABILIZING UNIT ON UNEVEN SURFACES
IMPORTANT
Unit Stabilizer Bracket Use (field-provided):
Always use stabilizers when unit is raised above the
factory height. (Elevated units could become unstable in
gusty wind conditions).
Stabilizers may be used on factory height units when
mounted on unstable an uneven surface.
With unit positioned at installation site
,
perform the
following
:
1. Remove two side louvered panels to expose the unit
base.
2. Install the brackets as illustrated in figure 36, detail D
using conventional practices.
3. Replace the panels after installation is complete.
ROOF MOUNTING
Install the unit a minimum of 6 inches (152 mm) above the
roof surface to avoid ice build-up around the unit. Locate
the unit above a load bearing wall or area of the roof that
can adequately support the unit. Consult local codes for
rooftop applications.
If unit coil cannot be mounted away from prevailing winter
winds, a wind barrier should be constructed. Size barrier at
least the same height and width as outdoor unit. Mount
barrier 24 inches (610 mm) from the sides of the unit in the
direction of prevailing winds.
NOTICE
Roof Damage!
This system contains both refrigerant and oil. Some
rubber roofing material may absorbed oil and cause the
rubber to swell when it comes into contact with oil. The
rubber will then bubble and could cause leaks. Protect
the roof surface to avoid exposure to refrigerant and oil
during service and installation. Failure to follow this
notice could result in damage to roof surface.
WIND BARRIER
PREVAILING WINTER
WINDS
INLET AIR
INLET AIR
INLET AIR
24 (610)
Figure 35. Rooftop Application and Wind Barrier —
Inches (Millimeters)
Содержание iComfort SL18XC1 Series
Страница 44: ...Page 44 XP17 Figure 21 Typical XP17 Wiring XP17 XX 230 06...
Страница 45: ...Page 45 XP17 Factory Wiring Diagrams Figure 22 Typical Factory Wiring XP17 XX 230 01...
Страница 46: ...Page 46 XP17 Figure 23 Typical Factory Wiring XP17 XX 230 02...
Страница 47: ...Page 47 XP17 Figure 24 Typical Factory Wiring XP17 XX 230 03 and 05...
Страница 48: ...Page 48 XP17 Figure 25 Typical Factory Wiring XP17 XX 230 06...