ELECTRICAL DATA

SPECIFICATIONS

Model No.

HS25–511

HS25–651

HS25–461

Outdoor

Coil

Condenser

Fan

HCFC–22 (charge  furnished)

Face area (sq.ft.)

Tube diameter (in.)

No. of Rows
Fins per inch

Diameter (in.)
No. of Blades

Motor hp
Cfm
RPM

Watts

Liquid line connection
Suction line connection

HS25–511

HS25–651

HS25–461

Model No.

Line voltage data – 60hz./1 phase

Compressor

Rated load amps

Power factor

Locked rotor amps

Condenser
Fan Motor

Full load amps

Locked rotor amps

Max fuse or c.b. size (amps)

*Minimum circuit ampacity

inner / outer

*Refer to National Electrical Code Manual to determine wire, fuse and disconnect size requirements.
NOTE – Extremes of operating range are plus 10% and minus 5% of line voltage

20.8/21.6

20.8/21.6

8.8/15.9

3/8

3/8

3/8

2.0

2.0

1.57

20

20

20

24

24

24

4

4

3

1/4

1/4

1/6

3870

4250

3100

840

820

820

330

350

205

13lbs. 8oz.

15lbs. 8oz.

8lbs. 5oz.

3/8

3/8

3/8

7/8

1-1/8

7/8

208/230V

208/230V

208/230V

23.7

28.8

20

.89

0.97

.97

129

169

107

1.7

1.6

1.1

3.1

3.8

2.0

50

60

45

31.3

37.7

26.1

SPECIFICATIONS

Model No.

HS25–261

HS25–311

HS25–411

Outdoor

Coil

Condenser

Fan

HCFC–22 (charge  furnished)

Face area (sq.ft.)

Tube diameter (in.)

No. of Rows
Fins per inch

Diameter (in.)
No. of Blades

Motor hp
Cfm
RPM

Watts

Liquid line connection
Suction line connection

inner / outer

- - -/11.8

5.4/11.8

5.5/15.9

HS25–211

5.5/15.9

3/8

3/8

3/8

3/8

1.0

1.48

1.36

1.36

20

20

20

20

20

20

24

24

4

4

3

3

1/6

1/6

1/6

1/6

2600

2450

3150

3150

820

820

820

820

200

210

215

210

6lbs. 2oz.

6lbs. 8oz.

8lbs. 1oz.

8lbs. 1oz.

3/8

3/8

3/8

3/8

5/8

3/4

3/4

3/4

ELECTRICAL DATA

HS25–261

HS25–311

HS25–411

Model No.

Line voltage data – 60hz./1 phase

Compressor

Rated load amps

Power factor

Locked rotor amps

Condenser
Fan Motor

Full load amps

Locked rotor amps

Max fuse or c.b. size (amps)

*Minimum circuit ampacity

*Refer to National Electrical Code Manual to determine wire, fuse and disconnect size requirements.
NOTE – Extremes of operating range are plus 10% and minus 5% of line voltage

HS25–211

208/230V

208/230V

208/230V

208/230V

11.6

13.5

18.0

.96

.96

.96

62.5

76.0

90.5

1.1

1.1

1.1

1.1

2.0

2.0

2.0

2.0

25

30

40

15.6

18.0

23.6

9.7

.96

50.0

20

13.3

Содержание HS25-211

Страница 1: ...must be matched according to Lennox recommendations for the compressor to be covered under warranty Refer to the Engineering Handbook for approved system matchups A misapplied system will cause errat...

Страница 2: ...1 7 1 6 1 1 3 1 3 8 2 0 50 60 45 31 3 37 7 26 1 SPECIFICATIONS Model No HS25 261 HS25 311 HS25 411 Outdoor Coil Condenser Fan HCFC 22 charge furnished Face area sq ft Tube diameter in No of Rows Fins...

Страница 3: ...uring a single orbit several pockets of gas are compressed simulta neously providing smooth continuous compression The scroll compressor is tolerant to the effects of liquid return If liquid enters th...

Страница 4: ...the compressor contactor On initial ther mostat demand the compressor contactor is delayed for 8 5 seconds At the end of the delay the compressor is allowed to energize When thermostat demand is sa t...

Страница 5: ...DISCHARGE TEMPERATURE SENSOR WIRES TO CONTROL BOX TO COMP TERM BOX IN 461 UNITS 3 1 2 TON AND SMALLER ONLY F High Pressure Switch A manual reset single pole single throw high pressure switch located...

Страница 6: ...application of field fabricated lines Separate discharge and suction service ports are pro vided at the compressor for connection of gauge man ifold during charging procedure Model No LIQUID SUCTION L...

Страница 7: ...rences are in construction Valves manufactured by Parker are forged assem blies Primore and Aeroquip valves are brazed to gether Valves are not rebuildable If a valve has failed it must be replaced Th...

Страница 8: ...h gauge manifold and connect vacuum pump with vacuum gauge to center port of gauge manifold With both gauge manifold ser vice valves open start pump and evacuate evapo rator and refrigerant lines IMPO...

Страница 9: ...table 6 as a general guide for performing main tenance checks Table 6 is not a procedure for charg ing the system Minor variations in these pressures may be expected due to differences in installation...

Страница 10: ...erminal Y passes through discharge temperature sensor compressor thermostat and low pressure switch to energize time delay terminal 2 3 Time delay action is at the beginning of a thermostat demand Whe...

Отзывы: