Page 20
D-Blower Speed Taps Leadless Motors
Blower speed tap selection is accomplished by changing the
taps at the blower motor harness connector. Disconnect harĆ
ness connector from motor to expose speed selectors.
Blower speed selections are listed in table 13.
To Change Blower Speed:
1 - Turn off electric power to furnace.
2 - Remove front panel and blower access door. See
figure 4.
3 - Disconnect blower motor harness from motor.
4 - Select desired speeds for heating and cooling (refer to
unit wiring diagram).
5 - Depress harness connector tab to release wire termiĆ
nal. Select connector location for new speed (refer to
unit wiring diagram). Insert wire terminal until it is seĆ
curely in place. See figure 23.
6 - Replace harness connector to motor.
FIGURE 23
BLOWER SPEED TAP SELECĆ
TION
LEADLESS MOTORS
HARNESS
CONNECTOR
MOTOR
DEPRESS TAB TO RELEASE
WIRE TERMINAL. SELECT
CONNECTOR
LOCATION
FOR NEW SPEED (REFER TO
UNIT WIRING DIAGRAM). INĆ
SERT WIRE UNTIL IT IS SEĆ
CURELY IN PLACE.
E-Blower Speed Taps Leaded Motors
Blower speed tap changes are made on the SureLight
control board. See figure 6. Unused taps must be secured
on dummy terminals "PARK M1" and or "PARK M2" on the
SureLight board. The heating tap is connected to the "ACB
HEAT " terminal and the cooling tap is connected to the
"ACB COOL" terminal. The continuous blower tap is conĆ
nected to the "ACB LOW" terminal.
To change existing heat tap, turn off power then switch out
speed tap on "ACB HEAT" with tap connected to "PARK
M1" or "PARK M2". See table 14 for blower motor tap colĆ
ors for each speed.
TABLE 13
TABLE 14
VI-MAINTENANCE
At the beginning of each heating season, the system
should be checked as follows:
A-Filters
A filter must be used in order to ensure long life and proper
operation. The filter is located in the return air duct or return
air register. Filters must be cleaned or replaced when dirty
to assure proper unit operation.
B-Heat Exchanger and Burners
NOTE-Use papers or protective covering in front of furĆ
nace while cleaning furnace.
Due to dimples designed in the heatexchanger, cleaning is
not recommended. Removal is for inspection only.