FOR YOUR SAFETY do not install or operate this appliance without 

first reading and understanding this manual. Any installation or 

operation of the appliance deviating from that which is stated 

in this manual WILL void the warranty and may be hazardous.

 INSTALLATION AND REPAIR SHOULD ONLY BE DONE BY 

A QUALIFIED SERVICE TECHNICIAN. DO NOT ATTEMPT 

TO SERVICE THE APPLIANCE YOURSELF.

 

Do not make any make-shift compromises during installation.  

Any modification or alteration may result in damage to the ap-

pliance or dwelling and will void the warranty, certification and 

listings of this unit.

 

Failure to use manufacturer provided parts, variations in tech-

niques and construction materials or practices other than those 

described in this manual may create a fire hazard and void the 

limited warranty.

 

This gas appliance must be equipped for the proper fuel type 

and altitude at which it will be operated. Any operation outside 

the parameters outlined in this manual may result in a hazard-

ous condition and will void the warranty. Please carefully read 

the sections pertaining to these subjects and/or be sure your 

appliance is properly equipped.

 Never use solid fuels such as wood, paper, cardboard, coal, or 

any flammable liquids, etc., in this appliance.

 

Any grill, panel, or glass removed for service MUST be replaced 

prior to operating the appliance. Do not operate appliance with 

the glass front removed, cracked or broken. 

 Gold  and  nickel  plated  surfaces  must  be  cleaned  with  glass 

cleaner  and  a  clean  soft  cloth  before  firing  the  first  time  or 

fingerprints will remain permanently. NEVER use brass polish 

to clean gold or nickel, this will remove the plating!!!

 When opening the right side door to access controls while the 

appliance is burning, pull on the lowest part of the side door as 

the side door could be hot.

 LHP, its employees, or any of its representatives assume no 

responsibility for any damages caused by an inoperable, inad-

equate, or unsafe condition as a result of any improper operation, 

service or installation procedures, whether direct or indirect.

 

Due to high temperatures, the appliance should be located out 

of traffic and away from furniture and draperies. 

 

En  raison  des  températures  élevées,  l’appareil  devrait  être 

installé dans un endroit où il y a peu de circulation et loin du 

mobilier et des tentures.

Provide adequate clearances around air openings and adequate 

accessibility clearance for service and proper operation. Never 

obstruct the front openings of the appliance.

These appliances are designed to operate on natural or propane 

gas only. The use of other fuels or combination of fuels will de-

grade the performance of this system and may be dangerous.

 

These appliances are designed as supplemental heaters. There-

fore, it is advisable to have an alternate primary heat source 

when installed in a dwelling.

These appliances must not be connected to a chimney or flue 

serving a separate solid fuel burning appliance.

 

These appliances are vented gas appliances. Do not burn wood 

or other material in these appliances.

 

This appliance is only for use with the type of gas indicated on 

rating plate. This appliance is not convertible for use with other 

gases, unless a certified kit is used.

 

Cet appareil doit être utilisé uniquement avec les types de gaz 

indiqués  sur  la  plaque  signalétique.    Ne  pas  l'utiliser  avec 

d'autres gaz sauf si un kit de conversion certifié est installé.

 

Hot while in operation. Do not touch. Severe Burns may result. 

Keep  children,  clothing  furniture,  gasoline  and  other  liquids 

having flammable vapors away.

 

L’appareil  est  chaud  lorsqu’il  fonctionne.  Ne  pas  toucher 

l’appareil. Risque de brûlures graves. Surveiller les enfants. 

Garder les vêtements, les meubles, l’essence ou autres liquides 

produisant des vapeur inflammables loin de l’appareil.

 

Ensure  clearances  are  in  accordance  with  local  installation 

codes and the requirements of the gas supplier.

 

Dégagement conforme aux codes d'installation locaux et aux 

exigences du foumisseunde gaz.

Installation and repair should be done by a qualified service 

person. The appliance should be inspected before use and at 

least annually by a professional service person. More frequent 

cleaning may be required due to excessive lint from carpet-

ing, bedding material, etcetera. It is imperative that control 

compartments, burners and circulating air passageways of the 

appliance be kept clean.

L’installation et la réparation devrait être confiées à un technicien 

qualifié. L’appareil devrait faire l’objet d’une inspection par un 

technicien professionnel avant d’être utilisé et au moins une 

fois l’an par la suite. Des nettoyages plus fréquents peuvent 

être nécessaires si les tapis, la literie, et cetera produisent une 

quantité importante de pous-sière. Il est essentiel que les com-

partiments abritant les commandes, les brûleurs et les conduits 

de circulation d’air de l’appareil soient tenus propres.

Do not use these appliances if any part has been under water.  

Immediately call a qualified, professional service technician 

to inspect the appliance and to replace any parts of the control 

system and any gas control which have been under water.

Ne pas utiliser cet appareil s’il a été plongé, même partielle-

ment, dans l’eau. Appeler un technicien qualifié pour inspecter 

l’appareil et remplacer toute partie du système de commande 

et toute commande qui a été plongée dans l’eau.

Only trim kit(s) supplied by the manufacturer shall be used in 

the installation of this appliance.

Seules les trousses de garniture fournies par le fabricant doivent 

être utilisées pour l’installation de cet appareil.

 INSTALLER:  THESE INSTRUCTIONS ARE TO REMAIN WITH THE 

HOME OWNER!

Содержание FIRESTAR MERIT GC3

Страница 1: ...an interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si...

Страница 2: ...10 Log Installation 10 Surround Panels Installation 11 Lower Front Filler Panel 12 Gas Line Installation 12 Gas Pressure Requirements 12 Gas Supply Line Sizing 12 LP and Natural Gas Supplies 13 Air Sh...

Страница 3: ...ting controls is danger ous WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de v tements ni d autres mati res inflamma...

Страница 4: ...lementalheaters There fore it is advisable to have an alternate primary heat source when installed in a dwelling These appliances must not be connected to a chimney or flue serving a separate solid fu...

Страница 5: ...built solid fuel wood burning fireplace listed to UL 127 or ULC S610 only All exhaust gases must be vented outside the structure Combustion air is drawn from outside the structure When installing in a...

Страница 6: ...ng List 1 Insert Body with Burner Cassette and trivet 1 Set of Refractory Brick Panels 3 pieces H5866 1 Log Set H5860 1 Lower front 2 filler panel 1 Fasteners 6 slotted 1 4 truss screws 4 speed nuts 6...

Страница 7: ...cleaned if it has been used to burn wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be dr...

Страница 8: ...any projections such as shelves window sills mantels spacers standoffs or surfaces to com bustible construction etc above the appliance Paint or lacquer used to finish the mantel must be heat resista...

Страница 9: ...ospheric pressure zone as the combustion air inlet to the appliance Flue Collar Connection This insert has a detachable flue collar to ease installation To detach flue collar lift removable vent trive...

Страница 10: ...nel into the top side brick retainer and then dropping the bottom of the panel into the bot tom retainer The rounded edge on the side brick panels goes toward the front 3 Piece Brick Panel Set The siz...

Страница 11: ...ing flanges to eliminate space between side and top flanges 5 Install two spring clips approximately five inches from each end of each of the three gold trim pieces The spring clips should be installe...

Страница 12: ...PES Fuel Type Inlet Pressure Manifold Pressure Desired Minimum Maximum On Hi Fire On Lo Fire Natural Gas 7 WC 5 WC 10 5 WC 3 5 WC 1 7 WC LP Gas 11 WC 10 5 WC 13 WC 10 0 WC 5 4 WC Table 1 1 2 1 3 cm 7...

Страница 13: ...begins to form after burning the air shutter should be opened gradually until the sooting condition stops Open the shutter a small amount at a time until the sooting ceases See Flame Color and Behavi...

Страница 14: ...hermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfourni...

Страница 15: ...don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a q...

Страница 16: ...a match or candle or smoke from a cigarette cigar or pipe OFF ON PiezoIgniter ON OFFSwitch No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No So...

Страница 17: ...further adjustment is necessary the blower will come on automati cally whenever the insert is warm 4 If you do not wish to have the blower on turn the knob until it clicks into the OFF position Optio...

Страница 18: ...e of the burner not igniting Follow the instructions included with the thermostat or remote control for wiring Millivolt and System Checks Check Test To Test Connect Meter Leads to Terminals Thermosta...

Страница 19: ...ance Checklist Should Only Be Performed by a Qualified Service Technician 1 Annual inspection should be made and the following checks per formed a With unit cool remove glass and inspect burner for di...

Страница 20: ...s of the front door see Figure 20a With the latches released rotate the catch part of each latch outward away from the front door The door will pivot toward you from the top hinging from the bottom as...

Страница 21: ...nnection Wire Black Pan Snap Switch Snap Switch Connection Wire White Speed Control Connection Speed control Connection Wire Black Blower Main Power Cord Black Main Power Cord Wire White Main Power Co...

Страница 22: ...roblem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot Pilot will not stay lit after carefully following lightin...

Страница 23: ...2 Per Stove H5982 Main Door Decorative Nickel Bars Each 2 Per Stove H6000 Middle Bay Glass W glass Tape Installed REPLACEMENT PARTS Firestar GC3 H5880 NG Pilot Assembly Includes Thermopile Electrode...

Страница 24: ...NG to LP Conversion Kit NG to LP ref form 775251M Trivets 75254 FSTR DVS2 TRV B Trivet Black 75248 FSTR DVS2 TRV G Trivet Gold 75249 FSTR DVS2 TRV N Trivet Nickel ACCESSORIES Firestar GC3 Finish Pane...

Страница 25: ...UR DU FOYER EXEMPTE DE MAT RIAUX COMBUSTIBLES D ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES MAINTENEZ LE BR LEUR ET LE BO TIER DES COMMANDES PROPRE EN TOUT TEMPS VOIR LES MANUELS D INSTALLATION...

Страница 26: ...res contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tr...

Страница 27: ...27 NOTES...

Страница 28: ...her documents for future refer ence Product reference information We recommend that you record the following important information aboutyourappliance PleasecontactyourLennoxHearthProductsdealer for an...

Отзывы: