SAFETY / LISTING LABEL

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

MODEL

FIRESTAR™

INSERT/GC3

SERIAL

 NO.

Report No. 050-S-07b-5

CHIMNEY-USE WITH B-VENT CHIMNEY OR SINGLE WALL GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.  

THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 

1,000 FT (405 M).

WARNING: OPERATION OF THIS APPLIANCE WHEN NOT CONNECTED TO A PROPERLY INSTALLED AND MAINTAINED 

VENTING SYSTEM OR TAMPERING WITH THE BLOCKED VENT SHUTOFF SYSTEM CAN RESULT IN CARBON MONOXIDE (CO) 

POISONING AND POSSIBLE DEATH.

DO NOT REMOVE OR COVER THIS LABEL

CAUTION:

 HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS 

AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING 

INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS 

APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. 

REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 

CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED 

WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED 

INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.

DATE OF MANUFACTURE

2010 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

2009

2008

2007

MINIMUM CLEARANCES

E**

F

H

D

C

Trim

Mantel

G

MINIMUM FIREPLACE SIZES REQUIRED

29.75” Front Opening

19.00” Opening Height

19.00” Rear Width

15.25” Fireplace Depth

INSERT HEARTH PROTECTION - Non-Combustible Hearth Extension

G = Minimum Hearth Protection 

G =

 Distance from Fireplace Facing

H = Vertical Distance from Insert

H =

 Bottom* to Combustible Material

Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible or 

equivalent, with a k factor of .84.

* Insert bottom is the metal lip below the lower gold trim bar.

CLEARANCES TO COMBUSTIBLES

A = 14.5” to Top Facing (max thickness 3/4”)

B = 24” to Mantel** (more than 3/4”)

C = 6.5” to Side Facing (3/4” or less)

D = 11” to Side Wall

E = 24” to Mantel**, more than 3/4” 

F = 14-1/2” to Top Facing, maximum thickness 3/4”

IGN

Part No. 36226 Rev. C, 3/2010

Manufactured by:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA 98071  USA

** The minimum distance from the top of the insert to a 

combustible may be reduced to 16” with a mantel shield. See 

installation and operation manual for shield dimensions.

Hearth / Floor Protection

G

23”

20”

17”

0”

H

0”

2”

4”

6”

US

Portland

LISTED VENTED GAS FIREPLACE HEATER - FIREPLACE INSERT - NOT FOR USE WITH SOLID FUEL

TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, CSA P.4.1-02, AND CGA 2.17-M91.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI 

Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED 

IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING 

FIREPLACES ONLY - MASONRY OR FACTORY BUILT.  THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. 
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE 

COMBUSTION AND VENTILATION AIR.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. SEE OWNER’S MANUAL FOR 

DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, 

FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USE) OR CSA C22-1-LATEST EDITION (CANADA).

FACTORY EQUIPPED FOR 

NATURAL GAS. IF CONTROL PANEL 

CONTRADICTS THIS LABEL, UNIT 

FUEL TYPE HAS BEEN CONVERTED.

RATINGS

NG

LP

NG

LP

Maximum Input BTU/hr 0-2000 Ft. (0-610 M)* 39,000 39,000   Minimum Inlet Pressure (IN. WC)

5

10.5

Minimum Input BTU/hr 0-2000 Ft. (0-610 M)*

27,500 22,600   Manifold Pressure - HI  (IN. WC/C.E.)

3.5

10

Orifice (DMS)*

#33

#49 

 Manifold Pressure - LO (IN. WC/C.E.)

1.7

3.5

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M

ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

 2010   2011   2012   2013

DANGER:

CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES 

ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS 

LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES 

VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT 

TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU 

VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE 

PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ 

PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.

AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE 

RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. 

RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN 

INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.

IGN

N’ENLEVEZ PAS   OU NE COUVREZ PAS CETTE ÉTIQUETTE

SPÉCIFICATIONS

NG

LP

NG

LP

Entrée Maximum BTU/hr 0-4500 Pi (0-1370 M)* 39,000 39,000   Pression Minimum D’entrée Du Gaz

 (IN. WC/C.E.)

5

10.5

Entrée Minimum BTU/hr 0-4500 Pi (0-1370 M)* 27,500 22,600   Pression À La Sortie - HI  (IN. WC/C.E.)

3.5

10

Orifice (DMS)*

#33

#49 

 Pression À La Sortie - LO (IN. WC/C.E.)

1.7

3.5

*EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL DIMINUE 

DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).

SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES

RÉFÉREZ-VOUS AU MANUEL D'INSTRUCTIONS DU PROPRIÉTAIRE POUR CHANGER LE BLOC D'ASSEMBLAGE DE LA VALVE.

Part No./ No. pièce #36266  Rev. B, 03/2010

MODÈLE

FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

SERIAL

 NO.

US

Portland

Número de Rapport  050-S-07b-5

DIMENSIONS MINIMUMS DE FOYER REQUISES

A = 29.75” Ouverture avant

B = 19.00” Hauteur

C = 19.00” Largeur arrière

D = 15.25” Profondeur du foyer

PROTECTION  DU FOYER

 G = Extension d’âtre min. devant  le foyer

 H = Distance verticale de la base

  de l’appareil aux combustibles

* La base du poêle encastrable est le repli de métal située sous la 

plaque de finition dorée. 
Note: Extension d’âtre fabriqué avec 3/8” (10mm) minimum de matériaux 

non-combustible ou équivalent possédant un facteur k de 0.84.

DIMENSIONS MINIMUMS DE FOYER REQUISES

 A = 14.5” (368mm) Ouverture avant

 B = 24” (610mm) Hauteur

C = 6.5” (165mm) Largeur arrière

 D = 11” (279mm) Profondeur du foyer

E = Dessus du foyer à partir de la base 24” (610mm)

F = Mur latéral à partir du centre du foyer 14.5” (368mm)

HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS UTILISER AVEC 

DU COMBUSTIBLE SOLIDE

TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», CSA P.4.1-02, ET CGA 2.17-M91.

CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION 

ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE 

INSTALLÉ SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE 

SOLIDE SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS 

CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.

CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES TYPES DE GAZ INDIQUÉS SUR LA PLAQUE SIGNALÉTIQUE. CET 

APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE 

DE CONVERSION HOMOLOGUÉE.

DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.

SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE 

CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

DÉGAGEMENTS MINIMUMS

MANTEAU

CHEMINÉE - ÉVACUATION :INSTALLER AVEC DE L’ÉVENT À GAZ DE TYPE B-VENT OU UN CONDUIT FLEXIBLE À SIMPLE 

PAROI HOMOLOGUÉ COMME TUBAGE.

CET APPAREIL DOIT ÊTRE RELIÉ À UN SYSTÈME D’ÉVACUATION TEL QUE SPÉCIFIÉ DANS LE MANUEL D’INSTALLATION DU 

FABRICANT.

AVERTISSEMENT : UTILISER CET APPAREIL AVEC UN SYSTÈME DE VENTILATION INADÉQUAT (MAUVAISE INSTALLATION OU 

MAUVAIS ENTRETIEN) OU ALTÉRER LE SYSTÈME D'ARRÊT AUTOMATIQUE EN CAS D'UN BLOCAGE D'ÉVENT PEUT CAUSER UN 

EMPOISONNEMENT AU MONOXYDE DE CARBONE QUI POURRAIT ENTRAÎNER LA MORT.

Le numéro de série est indiqué dans la 

section anglophone de cette étiquette

E**

F

H

D

C

Trim

Mantel

G

Protection Du Foyer

LA DATE DE FABRICATION EST INDIQUÉE DANS LA SECTION ANGLOPHONE DE CETTE ÉTIQUETTE

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI 

L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE ÉTIQUETTE, 

C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

FIRESTAR™

INSERT/GC3

G

584mm

508mm

432mm

0mm

H

0mm

51mm

102mm

152mm

MANTEAU

DE FOYER

PIÈCE DE 

FINITION

**  L'espace  minimum  entre  le  dessus  du  poêle 

encastrable et les matériaux combustibles peut être 

réduit à 16" en utilisant un protecteur de  manteau 

de cheminée.  Consultez le manuel d'installation et 

d'entretien pour les dimensions recommandées du 

protecteur.

Содержание FIRESTAR MERIT GC3

Страница 1: ...an interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si...

Страница 2: ...10 Log Installation 10 Surround Panels Installation 11 Lower Front Filler Panel 12 Gas Line Installation 12 Gas Pressure Requirements 12 Gas Supply Line Sizing 12 LP and Natural Gas Supplies 13 Air Sh...

Страница 3: ...ting controls is danger ous WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de v tements ni d autres mati res inflamma...

Страница 4: ...lementalheaters There fore it is advisable to have an alternate primary heat source when installed in a dwelling These appliances must not be connected to a chimney or flue serving a separate solid fu...

Страница 5: ...built solid fuel wood burning fireplace listed to UL 127 or ULC S610 only All exhaust gases must be vented outside the structure Combustion air is drawn from outside the structure When installing in a...

Страница 6: ...ng List 1 Insert Body with Burner Cassette and trivet 1 Set of Refractory Brick Panels 3 pieces H5866 1 Log Set H5860 1 Lower front 2 filler panel 1 Fasteners 6 slotted 1 4 truss screws 4 speed nuts 6...

Страница 7: ...cleaned if it has been used to burn wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be dr...

Страница 8: ...any projections such as shelves window sills mantels spacers standoffs or surfaces to com bustible construction etc above the appliance Paint or lacquer used to finish the mantel must be heat resista...

Страница 9: ...ospheric pressure zone as the combustion air inlet to the appliance Flue Collar Connection This insert has a detachable flue collar to ease installation To detach flue collar lift removable vent trive...

Страница 10: ...nel into the top side brick retainer and then dropping the bottom of the panel into the bot tom retainer The rounded edge on the side brick panels goes toward the front 3 Piece Brick Panel Set The siz...

Страница 11: ...ing flanges to eliminate space between side and top flanges 5 Install two spring clips approximately five inches from each end of each of the three gold trim pieces The spring clips should be installe...

Страница 12: ...PES Fuel Type Inlet Pressure Manifold Pressure Desired Minimum Maximum On Hi Fire On Lo Fire Natural Gas 7 WC 5 WC 10 5 WC 3 5 WC 1 7 WC LP Gas 11 WC 10 5 WC 13 WC 10 0 WC 5 4 WC Table 1 1 2 1 3 cm 7...

Страница 13: ...begins to form after burning the air shutter should be opened gradually until the sooting condition stops Open the shutter a small amount at a time until the sooting ceases See Flame Color and Behavi...

Страница 14: ...hermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfourni...

Страница 15: ...don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a q...

Страница 16: ...a match or candle or smoke from a cigarette cigar or pipe OFF ON PiezoIgniter ON OFFSwitch No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No So...

Страница 17: ...further adjustment is necessary the blower will come on automati cally whenever the insert is warm 4 If you do not wish to have the blower on turn the knob until it clicks into the OFF position Optio...

Страница 18: ...e of the burner not igniting Follow the instructions included with the thermostat or remote control for wiring Millivolt and System Checks Check Test To Test Connect Meter Leads to Terminals Thermosta...

Страница 19: ...ance Checklist Should Only Be Performed by a Qualified Service Technician 1 Annual inspection should be made and the following checks per formed a With unit cool remove glass and inspect burner for di...

Страница 20: ...s of the front door see Figure 20a With the latches released rotate the catch part of each latch outward away from the front door The door will pivot toward you from the top hinging from the bottom as...

Страница 21: ...nnection Wire Black Pan Snap Switch Snap Switch Connection Wire White Speed Control Connection Speed control Connection Wire Black Blower Main Power Cord Black Main Power Cord Wire White Main Power Co...

Страница 22: ...roblem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot Pilot will not stay lit after carefully following lightin...

Страница 23: ...2 Per Stove H5982 Main Door Decorative Nickel Bars Each 2 Per Stove H6000 Middle Bay Glass W glass Tape Installed REPLACEMENT PARTS Firestar GC3 H5880 NG Pilot Assembly Includes Thermopile Electrode...

Страница 24: ...NG to LP Conversion Kit NG to LP ref form 775251M Trivets 75254 FSTR DVS2 TRV B Trivet Black 75248 FSTR DVS2 TRV G Trivet Gold 75249 FSTR DVS2 TRV N Trivet Nickel ACCESSORIES Firestar GC3 Finish Pane...

Страница 25: ...UR DU FOYER EXEMPTE DE MAT RIAUX COMBUSTIBLES D ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES MAINTENEZ LE BR LEUR ET LE BO TIER DES COMMANDES PROPRE EN TOUT TEMPS VOIR LES MANUELS D INSTALLATION...

Страница 26: ...res contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tr...

Страница 27: ...27 NOTES...

Страница 28: ...her documents for future refer ence Product reference information We recommend that you record the following important information aboutyourappliance PleasecontactyourLennoxHearthProductsdealer for an...

Отзывы: