background image

5

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

SPECIFICATIONS - Model EBVI25

Figure 1

A

B

C

D

E

L

M

F

G

H

K

J

I

Front View

Side View

Top View

DIMENSIONS

inches (millimeter)

inches (millimeter)

A

26 5/8” (675 mm)

H

11 1/8” (282 mm)

B

20 1/2” (520 mm)

I

1 1/4” (31 mm)

C

13 3/8” (340 mm)

J

17 5/16” (439 mm)

D

SM - 41 1/16” (1043 mm)

MED. = 44 1/8” (1121 mm)

K

15 1/4” (388 mm)

E

SM.- 26 1/16” (662 mm)

MED. - 27 5/8” (702 mm)

L

**10 7/8” (276 mm)

F

19 3/8” (493 mm)

M

**24 7/8” (632 mm)

G

1 15/16” (49 mm)

** 

The total glass viewing area equals approx. 270 1/2  Sq. In

SPECIFICATIONS

Natural Gas BTU Input

17,000 to 25,000

Propane Gas BTU Input

19,500 to 25,000

B-Vent Size

4” Dia. Liner

Room Blower CFM

110 cfm

EFFICIENCIES

64 % Nat. Gas; 68 % Prop. Gas

Steady State Effi ciency *

79 % Nat. Gas; 81 % Prop. Gas

NOTES

* The Steady State Effi ciency numbers based on maximum vent confi guration.

Note: Due to Lennox' ongoing commitment to quality, all specifi cations, ratings 
and dimensions are subject to change without notice.

Содержание EVB125

Страница 1: ...DONN DANS CETTE NOTICE POURR DUIREAUMINIMUMLERISQUED INCENDIE OUPOUR VITERTOUTDOMMAGEMAT RIEL TOUTE BLESSURE OU LA MORT POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d all...

Страница 2: ...ermiculite one propane conversion kits One Warranty Certificate One Fireplace Warning Label One Draft Hood Sliding Tool This gas fireplace heater is a natural con vection heat circulating gas fireplac...

Страница 3: ...SUPPLY TO THE APPLIANCE AND HAVE IT SERVICED BY A QUALIFIED PROFES SIONAL AS IT MAY NOT BE OPERATING PROPERLY WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OFHIGHSURFACETEMPERATURES USE...

Страница 4: ...irements Familiarity with these requirements before installation is essential Some important considerationstodiscusswithlocalbuilding officials include 1 Applicablecodes i e UniformMechanical Code Sta...

Страница 5: ...5 8 702 mm L 10 7 8 276 mm F 19 3 8 493 mm M 24 7 8 632 mm G 1 15 16 49 mm The total glass viewing area equals approx 270 1 2 Sq In SPECIFICATIONS Natural Gas BTU Input 17 000 to 25 000 Propane Gas BT...

Страница 6: ...D 30 1 4 768 mm LG 30 762 mm L 12 3 8 314 mm F 20 7 8 530 mm M 23 7 16 595 mm G 1 13 16 46 mm SPECIFICATIONS Natural Gas BTU Input 21 500 to 30 000 Propane Gas BTU Input 22 000 to 28 000 B Vent Size 4...

Страница 7: ...ight Side Wall A G E C B Hearth Protection Side View TopofInsert Mantel Clearance Model EBVI30 The mantel should be located in the shaded area light gray shown below Existing Fireplace Hearth F 15 14...

Страница 8: ...pipe Refer to table 7 for suggested sizing of the gas supply line if black iron pipe is being used The gas supply line should be connected to the appliance at step 9 page 12 The gas supply line shoul...

Страница 9: ...OR MECHANICAL WEAKNESSES SUCH AS CRACKS LEAKY JOINTS CORRODED OR WARPED SURFACES THE FAULTY POR TION MUST BE REPAIRED OR REPLACED PRIOR TO INSTALLING THIS APPLIANCE Step 3 UNPACK THE INSERT Remove the...

Страница 10: ...termiation below the wall or parapet when distance is less than 10 ft as shown below wall or parapet wall or parapet No height above wall or parapet is required when dis tance is greater than 10 ft 7...

Страница 11: ...e it forward aligning with guide brackets until the screw hole in the spill tube aligns with the screw hole in the top of the firebox see Figure 12 Secure two parts in place with removed screw While p...

Страница 12: ...access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Make gas line connections All codes require a shut off valve mounted in the supply line Figure 19 illustrates two...

Страница 13: ...d fit onto corresponding pins and or log stoppers This will ensure a proper flame and safe combustion 1 Place the rear log onto the 2 corresponding locating pins at the back of the firebox as shown in...

Страница 14: ...ont of the forward logs Figure 29 Figure 30 9 Place some vermiculite around the logs as shown in Figure 30 the entire bag of vermiculite will NOT be used Vermiculite Figure 27 7 Install the Top Right...

Страница 15: ...donthe surround assembly see Figure 34 or operate the burner with the optional remote control wall thermostat or control switch Control Compartment Access Pull down hinged door to access control compa...

Страница 16: ...e the dial down clockwise just past the click the first ON position for the highest speed setting Turning the knob further clockwise will provide slower blower speeds Note If the rheostat is not turne...

Страница 17: ...ansparent These weak blue and transparent flames are termed anemic If the air shutter openings are too small sooting may develop IMPORTANT ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURI...

Страница 18: ...N 9 1466A SERIAL NUMBER NOMBRE DE SERIE XXX XXX IIIIIIIIIIIIIIIIIIII XXX P N 9 1466A MANTEAU DU DESSUS DE L APPAREIL MAX MAX MODEL NO EBVI25 MANUFACTURED AT Lynwood CA FOR USE WITH NATURAL GAS EQUIPE...

Страница 19: ......

Страница 20: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for code requirements for your area LHP 1110 West Taft A...

Отзывы: