5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
SPECIFICATIONS - Model EBVI25
Figure 1
A
B
C
D
E
L
M
F
G
H
K
J
I
Front View
Side View
Top View
DIMENSIONS
inches (millimeter)
inches (millimeter)
A
26 5/8” (675 mm)
H
11 1/8” (282 mm)
B
20 1/2” (520 mm)
I
1 1/4” (31 mm)
C
13 3/8” (340 mm)
J
17 5/16” (439 mm)
D
SM - 41 1/16” (1043 mm)
MED. = 44 1/8” (1121 mm)
K
15 1/4” (388 mm)
E
SM.- 26 1/16” (662 mm)
MED. - 27 5/8” (702 mm)
L
**10 7/8” (276 mm)
F
19 3/8” (493 mm)
M
**24 7/8” (632 mm)
G
1 15/16” (49 mm)
**
The total glass viewing area equals approx. 270 1/2 Sq. In
SPECIFICATIONS
Natural Gas BTU Input
17,000 to 25,000
Propane Gas BTU Input
19,500 to 25,000
B-Vent Size
4” Dia. Liner
Room Blower CFM
110 cfm
EFFICIENCIES
64 % Nat. Gas; 68 % Prop. Gas
Steady State Effi ciency *
79 % Nat. Gas; 81 % Prop. Gas
NOTES
* The Steady State Effi ciency numbers based on maximum vent confi guration.
Note: Due to Lennox' ongoing commitment to quality, all specifi cations, ratings
and dimensions are subject to change without notice.