SAFETY / LISTING LABEL

 

 

 

MODEL NO. 

EBVI30

 

MANUFACTURED AT: 

Union City, TN

 

FOR USE WITH NATURAL GAS.   EQUIPE POUR GAZ NATUREL

 

ALTITUDE 
 
MIN. GAS SUPPLY PRESS (“WC) 
PRESS MIN. D’ALIMENTATION (“ CE) 
MANIFOLD PRESSURE (“WC) 
PRESSION CE TUBULURE (“CE) 
MANUFACTURER’S RECOMMENDED ORIFICE SIZE 
DIMENSION DE L’INJECTEUR RECOMMANDE PAR 
MANUFACTURIER (DMS) 
MAX INPUT (BTU/HR) 
ENTREE MAX 
MIN INPUT (BTU/HR)  
ENTREE MIN 

0-4500 FT/PI 

(0-1370M) 

 

4.5” 

 

3.5” 

 

#37

 

30,000 

 

21,500 

ELECTRICAL RATING/EXI GENCES ELECTRIQUES: 

 

 

-UNIT/APPAREIL:  MILIVOLT 
1 ph 
60 HZ

 

120 VOLTS 
LESS THAN 5 AMPS 

MINIMUM 

SIDEWALL 

FLOOR 

8” 
0” 

CLEARANCES TO 

CEILING (FROM BOTTOM OF UNIT) 

64” 

COMBUSTIBLE 

MATERIAL 

 

MANTEL FROM TOP OF UNIT

 

18” 

MANTEL DEPTH 

12”

 

DEGAGEMENT

MUR ADJACENTS 

PLANCHER 

203mm 

0mm 

MINIMUM DE 

PLAFOND (DU BAS DE L’APPAREIL) 

1626mm  

MATERIAUX 

COMBUSTIBLES 

457mm

 

 

PROFONDEUR DU MANTEAU 

305mm  

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION 

IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE 

WITH AIR FILTERS. 

FOYER AU GAZ CHAUFFANT AVEC EVACUATION  - NE DOIT PAS ETRE UTILISE AVEC UN 

COMBUSTIBLE SOLIDE.  DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI 

BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU 

GAZ A EVACUATION. 

 

FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY. 

N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’ APPAREIL. 

“CAUTION: 

Do not operate the appliance with glass removed, cracked or broken.  

Replacement of panel should be done by a licensed or qualified service person.”  

“This appliance is equipped at the factory for use with natural gas only. Units using 

propane must be field converted using the LP conversion kit, Cat. No. H0920.

 

FINAL INSPECTION BY: 

 

ANSI Z21.88-2002 

CSA 2.33-2002 

CAN/CGA 2.17-M91 

 

VENTED GAS FIREPLACE HEATER 

FOYERA AU GAZ CHAUFFANT AVEC EVACUATION 

                                                                                                  P/N 9-1466A

 

SERIAL NUMBER/NOMBRE DE SERIE 

 

XXX XXX 

IIIIIIIIIIIIIIIIIIII 

XXX 

P/N 9-1466A 

MANTEAU  DU DESSUS DE L'APPAREIL

(MAX)

(MAX)

 

 

 

MODEL NO. 

EBVI25

 

MANUFACTURED AT: 

Lynwood, CA

 

FOR USE WITH NATURAL GAS.  EQUIPE POUR GAZ NATUREL

 

ALTITUDE 

 
MIN. GAS SUPPLY PRESS (“WC) 
PRESS MIN. D’ALIMENTATION (“ CE) 
MANIFOLD PRESSURE (“WC) 
PRESSION CE TUBULURE (“CE) 
MANUFACTURER’S RECOMMENDED ORIFICE SIZE 
DIMENSION DE L’INJECTEUR RECOMMANDE PAR 
MANUFACTURIER (DMS) 
MAX INPUT (BTU/HR) 
ENTREE MAX 
MIN INPUT (BTU/HR) 
ENTREE MIN 

0-4500 FT/PI 

(0-1370M) 

 

4.5” 

 

3.5” 

 

# 41

 

25,000 

 

17,000

ELECTRICAL RATING/EXI GENCES ELECTRIQUES: 

 

 

 

-UNIT/APPAREIL:  MILIVOLT 
1 ph 
60 HZ 
120 VOLTS 
LESS THAN 5 AMPS

MINIMUM

SIDEWALL 

FLOOR 

8” 
0” 

CLEARANCES TO 

CEILING (FROM BOTTOM OF UNIT) 

64”

 

COMBUSTIBLE 

MATERIAL 

 

MANTEL FROM TOP OF UNIT LOUVER

 

15 1/2”

 

   M ANTEL 

(MAX) 

12”

 

DEGAGEMENT    MUR 

ADJACENTS 

PLANCHER 

203 mm 

0 mm 

MINIMUM DE 

PLAFOND (DU BAS DE L’APPAREIL) 

1626 mm  

MATERIAUX 

COMBUSTIBLES 

394 mm  

 

PROFONDEUR DU MANTEAU 

305 mm 

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION 

IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE 

WITH AIR FILTERS. 

FOYER AU GAZ CHAUFFANT AVEC EVACUATION  - NE DOIT PAS ETRE UTILISE AVEC UN 

COMBUSTIBLE SOLIDE.  DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI 

BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU 

GAZ A EVACUATION. 

 

FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY. 

N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’ APPAREIL. 

“CAUTION: 

Do not operate the appliance with glass removed, cracked or broken.  

Replacement of panel should be done by a licensed or qualified service person.”  

“This appliance is equipped at the factory for use with natural gas only. Units using 

propane must be field converted using the LP conversion kit, Cat. No. H1576.

 

FINAL INSPECTION BY: 

 

ANSI Z21.88-2002 

CSA 2.33-2002 

CAN/CGA 2.17-M91 

 

VENTED GAS FIREPLACE HEATER 

FOYERA AU GAZ CHAUFFANT AVEC EVACUATION 

                                                                                                  P/N  9-1466B

 

SERIAL NUMBER/NOMBRE DE SERIE 

 

XXX XXX 

IIIIIIIIIIIIIIIIIIII 

XXX 

P/N 9-1466B

MANTEAU  DU DESSUS DE L'APPAREIL

 

DEPTH 

(MAX) 

Содержание EVB125

Страница 1: ...DONN DANS CETTE NOTICE POURR DUIREAUMINIMUMLERISQUED INCENDIE OUPOUR VITERTOUTDOMMAGEMAT RIEL TOUTE BLESSURE OU LA MORT POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d all...

Страница 2: ...ermiculite one propane conversion kits One Warranty Certificate One Fireplace Warning Label One Draft Hood Sliding Tool This gas fireplace heater is a natural con vection heat circulating gas fireplac...

Страница 3: ...SUPPLY TO THE APPLIANCE AND HAVE IT SERVICED BY A QUALIFIED PROFES SIONAL AS IT MAY NOT BE OPERATING PROPERLY WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OFHIGHSURFACETEMPERATURES USE...

Страница 4: ...irements Familiarity with these requirements before installation is essential Some important considerationstodiscusswithlocalbuilding officials include 1 Applicablecodes i e UniformMechanical Code Sta...

Страница 5: ...5 8 702 mm L 10 7 8 276 mm F 19 3 8 493 mm M 24 7 8 632 mm G 1 15 16 49 mm The total glass viewing area equals approx 270 1 2 Sq In SPECIFICATIONS Natural Gas BTU Input 17 000 to 25 000 Propane Gas BT...

Страница 6: ...D 30 1 4 768 mm LG 30 762 mm L 12 3 8 314 mm F 20 7 8 530 mm M 23 7 16 595 mm G 1 13 16 46 mm SPECIFICATIONS Natural Gas BTU Input 21 500 to 30 000 Propane Gas BTU Input 22 000 to 28 000 B Vent Size 4...

Страница 7: ...ight Side Wall A G E C B Hearth Protection Side View TopofInsert Mantel Clearance Model EBVI30 The mantel should be located in the shaded area light gray shown below Existing Fireplace Hearth F 15 14...

Страница 8: ...pipe Refer to table 7 for suggested sizing of the gas supply line if black iron pipe is being used The gas supply line should be connected to the appliance at step 9 page 12 The gas supply line shoul...

Страница 9: ...OR MECHANICAL WEAKNESSES SUCH AS CRACKS LEAKY JOINTS CORRODED OR WARPED SURFACES THE FAULTY POR TION MUST BE REPAIRED OR REPLACED PRIOR TO INSTALLING THIS APPLIANCE Step 3 UNPACK THE INSERT Remove the...

Страница 10: ...termiation below the wall or parapet when distance is less than 10 ft as shown below wall or parapet wall or parapet No height above wall or parapet is required when dis tance is greater than 10 ft 7...

Страница 11: ...e it forward aligning with guide brackets until the screw hole in the spill tube aligns with the screw hole in the top of the firebox see Figure 12 Secure two parts in place with removed screw While p...

Страница 12: ...access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Make gas line connections All codes require a shut off valve mounted in the supply line Figure 19 illustrates two...

Страница 13: ...d fit onto corresponding pins and or log stoppers This will ensure a proper flame and safe combustion 1 Place the rear log onto the 2 corresponding locating pins at the back of the firebox as shown in...

Страница 14: ...ont of the forward logs Figure 29 Figure 30 9 Place some vermiculite around the logs as shown in Figure 30 the entire bag of vermiculite will NOT be used Vermiculite Figure 27 7 Install the Top Right...

Страница 15: ...donthe surround assembly see Figure 34 or operate the burner with the optional remote control wall thermostat or control switch Control Compartment Access Pull down hinged door to access control compa...

Страница 16: ...e the dial down clockwise just past the click the first ON position for the highest speed setting Turning the knob further clockwise will provide slower blower speeds Note If the rheostat is not turne...

Страница 17: ...ansparent These weak blue and transparent flames are termed anemic If the air shutter openings are too small sooting may develop IMPORTANT ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURI...

Страница 18: ...N 9 1466A SERIAL NUMBER NOMBRE DE SERIE XXX XXX IIIIIIIIIIIIIIIIIIII XXX P N 9 1466A MANTEAU DU DESSUS DE L APPAREIL MAX MAX MODEL NO EBVI25 MANUFACTURED AT Lynwood CA FOR USE WITH NATURAL GAS EQUIPE...

Страница 19: ......

Страница 20: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for code requirements for your area LHP 1110 West Taft A...

Отзывы: