background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

2

INTRODUCTION 

This appliance complies with National 
Safety Standards and is tested and listed 
by OMNI-Test Laboratories Inc.; Beaverton, 
Oregon (Report No. 116-F-15-5) to ANSI 
Z21.88-2002 (in Canada, CSA-2.33-2002), 
and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas fi red room heater.  

TABLE OF CONTENTS 

Packaging List 

page  2

Introduction page 

2

General Information 

page  3

Questions/Building Offi cials 

page  4

High Altitude 

page  4

Fireplace Requirements 

page  4

Specifi cations 

page  5

Clearance to Combustibles 

page  7

Step 1 Preparation 

page  8

Step 2 Clean Fireplace 

page  8

Step 3 Unpack the insert. 

page  9

Step 4 Lift Insert into Position 

page  9

Step 5 Remove Glass Door 

page  9

Step 6 Remove Firebox Contents 

page  9

Step 7 Install LP Conv. (if necessary)  page  9
Step 8 Install Venting 

page  9

Step 9 Connect Gas Line 

page  12

Step 10 Purge Air 

page  12

Step 11 Install Log Set 

page  13

Step 12 Reinstall Front Glass Door 

page  14

Step 13 Perform Leak Test 

page  14

Step 14 Install Surround Assembly 

page  14

Step 15 Install Wall Thermostat 

page  14

Step 16 Check Appliance Operation 

page  14

Step 17 Perform Spillage Test 

page  16

Step 18 Check Blower Operation 

page  16

Step 19 Adjust Burner  

page  17

Step 20 Install Louver Kit 

page  17

Rating Plates 

page  18

PLEASE READ AND UNDERSTAND THESE 
INSTRUCTIONS BEFORE BEGINNING 
YOUR INSTALLATION.

This installation manual will help you obtain 
a safe, effi cient, dependable installation for 
your appliance and vent system. 

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-
FACTURED BY LENNOX HEARTH PRODUCTS.

 

When you purchased your new gas fi red heater, you joined the ranks of thousands of 

concerned individuals whose answer to their home heating needs refl ects their concern for 
aesthetics, effi ciency and our environment. We extend our continued support to help you 
achieve the maximum benefi t and enjoyment available from your new gas fi red heater. It 
is our goal at Lennox Hearth Products to provide you, our valued customer, with an appli-
ance that will ensure you years of trouble free warmth and pleasure. 
 

Thank you for selecting a Lennox Hearth Products gas fi red heater as the answer to 

your home heating needs.

Sincerely, 
All of us at Lennox Hearth Products

PACKAGING LIST

The assembled vented gas fi replace heater 
is packaged with:

•  One accessory package containing a 
literature package (installation and operation 
instruction manuals) is located on top of the 
appliance.
•  One log set, one bag of embers, one bag of 
vermiculite, one propane conversion kits.
•   One Warranty Certifi cate.
•   One Fireplace Warning Label.
•   One Draft Hood Sliding Tool.

This gas fi replace heater is a natural con-
vection, heat circulating gas fi replace insert 
designed for residential applications.This 
heater is designed to be installed into an exist-
ing masonry or factory built solid fuel burning 
fi replace only - Masonry fi replace must be 
built to UBC 37 or ULC S628 standards and 
factory built (zero clearance) fi replace must be 
listed to UL 127 or ULC S610. Units must use 
a 4” listed B-Vent or listed liner (conforming 
to UL 1777) from the appliance outlet to the 
chimney termination. The venting system 
must be routed through the existing fi replace 
fl ue system to the vent termination. 

This millivolt appliance is designed to oper-
ate on natural gas or propane gas only.

 

A millivolt gas control valve with piezo igni-
tion system provides safe, effi cient operation. 
External electrical power is required to operate 
the blower.

This appliance may be used with a thermo-
stat (see Optional Wall Thermostat). This 
appliance is certifi ed for use in bedrooms.  
If installed in a bedroom in Canada, a ther-
mostat IS required.

This appliance requires an adequate supply 
of combustion and ventilation air. As an 
aid in determining whether or not these 
requirements have been satisfi ed, follow the 
procedure indicated in the section entitled 
Spill Test Procedure (see page 16). 

The millivolt appliance is manually con-
trolled and features a spark igniter (piezo) 
that allows the appliance's pilot gas to be 
lit without the use of matches or batteries.  
This system provides continued service in 
the event of a power outage.

This unit is factory set for use with Natural 
Gas and will require a fi eld conversion for use 
with Propane (other fuels are NOT allowed).  
The use of other fuels or combination of fuels 
will degrade the performance of this system 
and may be dangerous.

DO NOT ATTEMPT TO ALTER OR MODIFY 
THE CONSTRUCTION OF THE APPLIANCE OR ITS 
COMPONENTS. ANY MODIFICATION OR ALTERA-
TION MAY VOID THE WARRANTY, CERTIFICATION 
AND LISTINGS OF THIS UNIT.

Installation must conform to local codes. In 
the absence of local codes, installation must 
comply with the current National Fuel Gas 
Code, ANSI Z223.1. (In Canada, the current 
CAN-1 B149 installation code.)  Electrical 
wiring must comply with the National Elec-
trical Code ANSI/ NFPA 70 - latest edition.  
In Canada, the current CSA C22-1 Canadian 
Electrical Code - latest edition.

MODEL: EBVI30

SKS-30, Surround Kit, Small 
 

(40 1/4" W x 27 1/2" H)

SKM-30, Surround Kit, Medium 
 

(45 3/4" W x 30 1/4" H)

SKL-30, Surround Kit, Large 
 

(49 1/4" W x 30" H)

MODEL: EBVI25

SKS-25, Surround Kit, Small 
 

(41 1/16" W x 26 1/16" H)

SKM-25, Surround Kit, Medium 
 

(44 1/8" W x 27 5/8" H)

SURROUND ASSEMBLY SOLD SEPA-
RATELY 

Содержание EVB125

Страница 1: ...DONN DANS CETTE NOTICE POURR DUIREAUMINIMUMLERISQUED INCENDIE OUPOUR VITERTOUTDOMMAGEMAT RIEL TOUTE BLESSURE OU LA MORT POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d all...

Страница 2: ...ermiculite one propane conversion kits One Warranty Certificate One Fireplace Warning Label One Draft Hood Sliding Tool This gas fireplace heater is a natural con vection heat circulating gas fireplac...

Страница 3: ...SUPPLY TO THE APPLIANCE AND HAVE IT SERVICED BY A QUALIFIED PROFES SIONAL AS IT MAY NOT BE OPERATING PROPERLY WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OFHIGHSURFACETEMPERATURES USE...

Страница 4: ...irements Familiarity with these requirements before installation is essential Some important considerationstodiscusswithlocalbuilding officials include 1 Applicablecodes i e UniformMechanical Code Sta...

Страница 5: ...5 8 702 mm L 10 7 8 276 mm F 19 3 8 493 mm M 24 7 8 632 mm G 1 15 16 49 mm The total glass viewing area equals approx 270 1 2 Sq In SPECIFICATIONS Natural Gas BTU Input 17 000 to 25 000 Propane Gas BT...

Страница 6: ...D 30 1 4 768 mm LG 30 762 mm L 12 3 8 314 mm F 20 7 8 530 mm M 23 7 16 595 mm G 1 13 16 46 mm SPECIFICATIONS Natural Gas BTU Input 21 500 to 30 000 Propane Gas BTU Input 22 000 to 28 000 B Vent Size 4...

Страница 7: ...ight Side Wall A G E C B Hearth Protection Side View TopofInsert Mantel Clearance Model EBVI30 The mantel should be located in the shaded area light gray shown below Existing Fireplace Hearth F 15 14...

Страница 8: ...pipe Refer to table 7 for suggested sizing of the gas supply line if black iron pipe is being used The gas supply line should be connected to the appliance at step 9 page 12 The gas supply line shoul...

Страница 9: ...OR MECHANICAL WEAKNESSES SUCH AS CRACKS LEAKY JOINTS CORRODED OR WARPED SURFACES THE FAULTY POR TION MUST BE REPAIRED OR REPLACED PRIOR TO INSTALLING THIS APPLIANCE Step 3 UNPACK THE INSERT Remove the...

Страница 10: ...termiation below the wall or parapet when distance is less than 10 ft as shown below wall or parapet wall or parapet No height above wall or parapet is required when dis tance is greater than 10 ft 7...

Страница 11: ...e it forward aligning with guide brackets until the screw hole in the spill tube aligns with the screw hole in the top of the firebox see Figure 12 Secure two parts in place with removed screw While p...

Страница 12: ...access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Make gas line connections All codes require a shut off valve mounted in the supply line Figure 19 illustrates two...

Страница 13: ...d fit onto corresponding pins and or log stoppers This will ensure a proper flame and safe combustion 1 Place the rear log onto the 2 corresponding locating pins at the back of the firebox as shown in...

Страница 14: ...ont of the forward logs Figure 29 Figure 30 9 Place some vermiculite around the logs as shown in Figure 30 the entire bag of vermiculite will NOT be used Vermiculite Figure 27 7 Install the Top Right...

Страница 15: ...donthe surround assembly see Figure 34 or operate the burner with the optional remote control wall thermostat or control switch Control Compartment Access Pull down hinged door to access control compa...

Страница 16: ...e the dial down clockwise just past the click the first ON position for the highest speed setting Turning the knob further clockwise will provide slower blower speeds Note If the rheostat is not turne...

Страница 17: ...ansparent These weak blue and transparent flames are termed anemic If the air shutter openings are too small sooting may develop IMPORTANT ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURI...

Страница 18: ...N 9 1466A SERIAL NUMBER NOMBRE DE SERIE XXX XXX IIIIIIIIIIIIIIIIIIII XXX P N 9 1466A MANTEAU DU DESSUS DE L APPAREIL MAX MAX MODEL NO EBVI25 MANUFACTURED AT Lynwood CA FOR USE WITH NATURAL GAS EQUIPE...

Страница 19: ......

Страница 20: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for code requirements for your area LHP 1110 West Taft A...

Отзывы: