NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE.
24
Figure 24-2
LENNOX HEARTH PRODUCTS • ELITE LINEAR VIEW DIRECT-VENT GAS FIREPLACE (MODELS LDV42, LDV54) • INSTALLATION INSTRUCTIONS
Figure 24-1: Junction Box Wiring
fIELD WIRINg STEPS
Route wiring and install electrical components
in the order described in this section.
Route fireplace wiring.
(See Figures 24-1 and 24-2)
Note: The electronic appliance must be
connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1ph power
supply (not provided) to the appliance
junction box.
2. Remove the electrical inlet cover plate from
the back of the unit by removing the plate’s
securing screws. The junction box can be
moved to the bottom of the fireplace for
bottom electrical entry.
3. Remove the cover plate knockout; then
feed the power supply wire through the
knockout opening and into the unit junction
box.
4. Connect the black power supply wire to
the
power outlet’s
red pigtail lead and the
white power supply wire to the
common
terminal of the outlet
.
5. Connect the ground supply wire to the
pigtail lead attached to the outlet’s green
ground screw.
6. After wiring is complete, replace the cover
plate.
green
ground
Screw
Black
hot
Side of
Receptacle
Tab Intact
Tab Intact
green
White
Neutral
Side of
Receptacle
120 VAC - Black
Neutral - White
ground - green
j-BOx / RECEPTACLE
WIRINg
120V, 60hZ, 1Ph
junction Box
field Wired
factory Wired
(Power Supply
Unswitched)
CAUTION
ground supply lead must be con-
nected to the wire attached to the
green ground screw located on the
outlet box. failure to do so will
result in a potential safety hazard.
The appliance must be electrically
grounded in accordance with local
codes or, in the absence of local
codes, the National Electrical Code,
ANSI/NfPA 70, latest edition (in
Canada, the current CSA C22-1
Canadian Electrical Code).
CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs
de cáblage peu-vent entraîner un fonc-
tionnement inadéquat et dangereux.
Verify proper operation after servicing.
S’assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
fIELD WIRINg
P/N 580491-01
ELECTRONIC WIRING DIAGRAM FOR GRAVITY VENT FIREPLACES
JUNCTION BOX
120V AC
REMOTE RECEIVER
ON/OFF SWITCH
WALL SWITCH
LIMIT SWITCH
B-VENT MODELS
ONLY
AC/DC
POWER
ADAPTOR
HOT
NEUTRAL
OPTIONAL
GROUND
BATTERY HOLDER
DFC WIRE HARNESS
SPARK WIRE CABLE
PILOT GROUND WIRE
PILOT
SENSOR
CABLE
HOOD
IGNITER ROD
FLAME SENSOR
PILOT TUBE
OPTIONAL CPI SWITCH
OFF (O) = INTERMITTENT PILOT MODE
ON (-) = STANDING PILOT MODE
PROFLAME DFC BOARD
PROFLAME VALVE
ELECTRONIC PILOT ASSEMBLY
B = BLACK
BR = BROWN
GY = GRAY
PU = PURPLE
R = RED
BL = BLUE
G = GREEN
O = ORANGE
W = WHITE
Y = YELLOW
WIRING COLOR CODE
B
B
B
R
R
W
W
B
B
B
B
BL
BL
G
G
O
Y
Y
R
R
Y
W
G
G
O
SCHEMATIC REPRESENTATION ONLY