REqUIRED hORIZONTAL VENTINg COMPONENTS  

BASED ON ExTERIOR WALL ThICkNESS

Ext. Wall Thickness 

inches (mm)

Required horizontal 

Vent Components

6 to 9-1/4 

(152 to 235)

• Termination Kit

10-3/4 to 14 

(273 to 356)

• Termination Kit

• 6-inch Vent Section

16-3/4 to 20 

(426 to 508)

• Termination Kit

• 12-inch Vent Section

11-3/4 to 20 

(299 to 508)

• Termination Kit

• Telescopic Vent Section

Figure 23-3

Figure 23-2: Horizontal Termination Venting Connection and Exterior Wall Recessing

Siding

Stucco

Max. 1-1/4" Recess of

Horizontal Termination into

Exterior Finishing Material 

Exterior Surface

of Framing

6" to 9-1/4"

(152 to 235 mm)**

Exterior Surface of Siding

Interior Surface of

Finished Wall

Max. 9-1/4" (235 mm)

Wall Thickness**

Typical Horizontal

Termination

Maximum Extent of

Vent Run Section

Relative to Exterior

Surface of Framing

Last Vent Section

(Use 

Telescopic 

Vent Section

if necessary.)

Termination

Adapter

Horizontal Termination Venting Connection and Exterior Wall Recessing

*Use silicone caulk to seal the top and sides of the termination, 

  up to the underlayment, stucco, or masonry wall surface.

Caulk*

Typical Horizontal

Termination

Caulk*

**For walls thicker than 9-1/4", see 

Figure 23-3.

LENNOX HEARTH PRODUCTS  •  ELITE LINEAR VIEW DIRECT-VENT GAS FIREPLACE (MODELS LDV42, LDV54)  •  INSTALLATION INSTRUCTIONS

INSTALLINg hORIZONTAL VENT  

TERMINATION

1. Assemble vent run to exterior wall.

a) If not already done, prepare an opening as 

described in 

Figure 23-1

.

b) Assemble  the  vent  system  to  the  point 

where the end of the last section is within 

5 to 8-1/2 inches (127 to 216 mm) inboard 

of the exterior surface to which the termina-

tion will be attached. See 

Figure 23-1 and 

23-3

.

  If the end of the last section is not within this 

distance, use the 

telescopic vent section 

as 

the last vent section (see 

Page 14

)

Note: 

For  walls  thicker  than  those  shown  in 

Figure 23-2

, see 

Figure 23-3

, which lists addi-

tional venting components needed (in addition 

to the termination and adaptor) for a particular 

range of wall thicknesses.

2. Attach termination adaptor.

See 

Figure  23-2

.  Attach  the 

termination 

adaptor 

(provided  with  the  termination)  to 

the vent section (or telescoping vent section 

or  elbow)  in  the  same  manner  as  the  other 

vent components (see "Attaching Secure Vent 

Components" on 

Page 13

).

Note: If blown insulation is to be 

used, the Through-Wall Shield kit 

(h5816) MUST be installed.

3. Install firestop/spacer  

at exterior wall.

See 

Figure  23-1

.  Install  the 

firestop/spacer

 

over  the  opening  at  the  exterior  side  of  the 

framing, long side up, with the 3-inch spacer 

clearance at the top, and nail into place. (The 

firestop/spacer also may be installed over the 

opening at the interior side of framing).

4. Install horizontal termination.

a) From  outside  the  exterior  wall,  slide  the 

horizontal  termination

  collars  onto  the 

termination  adaptor

  (the  outer  termina-

tion collar INSIDE the outer diameter of the 

adapter,  and  the  inner  termination  collar 

OUTSIDE the inner diameter of the adapter) 

until the termination seats against the exte-

rior wall surface to which it will be attached.

b) Orient  the  termination  housing  with  the 

 arrow pointing UP (see 

Figure 23-2

)

c) Secure the termination to the exterior wall. 

Figure 23-1: Installing Horizontal Termination

Firestop/Spacer (SV4.5HF) shown

on the exterior side of the wall. It

may also be installed on the

interior side.

Typical

Termination

Shown

7"

(178)

5-1/8"

(130 mm)

12-1/8"

(308 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Frame Opening.

6 to 48 inch Vent Section,

Telescopic vent section,

Elbow or Appliance Collar

Base of Appliance

3"

(76 mm)

1"

(25.4 mm)

Adapter

SV4.5RCH

10-1/2"

(267 mm)

See 

Page 8

 for 

min. height from

 appliance 

base 

to 

vertical centerline of vent pipe.

NOTE:  The  horizontal  termination  must  not 

be recessed into the exterior wall or siding

 

by more than 1-1/4" (32 mm), as shown in 

Figure 23-2

.

CAUTION:  The  vent  termination  is  hOT 

while in operation and for a period of time 

following fireplace use. To  prevent  con-

tact with hot surfaces, use a 

Termination 

Guard

, which can be purchased at your 

local dealer. 

(See “

Installation Accesso-

ries

” in this manual for catalog numbers.)

Use the table in Figure 23-3 when selecting 

venting components for a particular  range of 

exterior wall thicknesses.

hORIZONTAL TERMINATION SySTEMS

(CONTINUED)

Содержание ELITE LDV42N

Страница 1: ...is or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Страница 2: ...allation Instructions this manual Care and Operation Instructions Safety in Operation Warnings Warranty Vent restrictor assembly Remote control kit handheld remote control transmitter remote control r...

Страница 3: ...proper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning Do not attempt to alter or modify the construction of the applianc...

Страница 4: ...e ON OFF function only Efficiencies Fireplace Model Natural Gas Propane AFUE EnerGuide P4 AFUE EnerGuide P4 ldv42 66 7 54 2 69 6 59 4 ldv54 71 9 63 2 72 1 65 5 AFUE Annual Fuel Utilization Efficiency...

Страница 5: ...with certain vent runs 16 Reinstall baffle if removed for vent restrictor installation 28 Install media 27 Install glass door 29 12 Verify appliance operation 30 Lighting instructions 31 Air shutter a...

Страница 6: ...of the mantel UNPROTECTED Side Wall See Figure 6 4 for minimum clearances to unprotected side walls FINISH SURROUND IMPORTANT The factory supplied non com bustible fiber board MUST be installed aroun...

Страница 7: ...fireplace the nailing flanges MUST be adjusted according to finish cleanface or surround and wall finish material thickness This is critical to ensure proper fireplace location especially if installi...

Страница 8: ...or dimension information only Fireplace must be adequately framed and supp A Required frame opening width 1 2 of A horizontal centerline of fireplace and vent framing opening B Required frame opening...

Страница 9: ...vertical position for cleanface finish and at 1 2 wall finish depth Cleanface Finish Nailing Flange Settings 1 Leave vertical position of nailing flanges at factory setting see Figure 9 1 DETAIL A 2 I...

Страница 10: ...opane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery which can cause sooting severe delayed ignition or other malfunctions ref NPFA 58 Any damage as a result of insu...

Страница 11: ...alified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Figure 11 3 Gas Stub 1 2...

Страница 12: ...t all factory and field connections for gas leaks Note Even though soapy water is an effective leak test solution it is NOT recommended because soap residue can corrode pipes and fittings over time 1...

Страница 13: ...against the adjoining section until fully engaged 3 Twist the section being attached CLOCK WISE running the dimples down and along the channels until seated at the ends of the channels The sections ar...

Страница 14: ...L 2 1 4 2 1 0 1 2 1 2 2 2 1 4 3 2 1 6 4 t n e V f o t h g i e H s n o i t c e S t n e V f o r e b m u N s e h c n i t f 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5...

Страница 15: ...bove appliance vent outlet VENT RUN SUPPORT REQUIREMENTS Supporting Vertical Vent Runs Note Proper venting support is very important NEVER use the fireplace to support the weight of the venting Suppor...

Страница 16: ...o slide the assembly up into the vent collar as shown in Figure 16 3 The vent restrictor is held in place by fric tion only The entire vent restrictor assembly must be up inside the vent collar with n...

Страница 17: ...ofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeov...

Страница 18: ...provided Vent Restrictor if re quired see Page 16 A 90 elbow may NOT be attached directly to the appliance collar A minimum of 6 pipe must be used between the fireplace collar and a 90 elbow For more...

Страница 19: ...screw c Apply non combustible caulking silicone caulking is acceptable around entire cir cumference to ensure a water tight seal LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODE...

Страница 20: ...rtical Firestop Spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal Firestop Spacer must be used anywhere vent pipe passes through a combustible wall For fu...

Страница 21: ...termination must have a minimum 6 152 mm clearance to any overhead combustible projection less than or equal to 2 1 2 64 mm For projections greater than 2 1 2 64 mm see Figure 21 1 For additional vent...

Страница 22: ...U S 12 in Canada V L B J X V A G Inside Corner Detail B C C C 18 Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6 Inside Corner See Item D in the Text Below V P V O N N Q NOTE Local...

Страница 23: ...Attach termination adaptor See Figure 23 2 Attach the termination adaptor provided with the termination to the vent section or telescoping vent section or elbow in the same manner as the other vent co...

Страница 24: ...1PH Junction Box Field Wired Factory Wired Power Supply Unswitched CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box Failure to do...

Страница 25: ...can turn on suddenly Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system CAUTION Propertydamagehazard Excessive heat can cause propert...

Страница 26: ...is turned off The receiver beeps 2 times Low Battery Detection Remote Control The life of the Remote Control batteries depends on many factors including battery quality and number of appliance ignitio...

Страница 27: ...complete combus tion sooting and poor flame quality and will void the warranty Rear Floor Section Rear Ledge Tab Side Panel Center Lower Tab Reinstall front floor section 1 See Figure 27 2 Engage lowe...

Страница 28: ...allelectricitytotheappliancebeforeinstallingmedia If media is not installed according to the installation instructions flame impingement and improper combustion could occur resulting in soot This appl...

Страница 29: ...tempt to substitute the materials used on these doors or replace cracked or broken glass The glass door s of this appliance must onlybereplacedasacompleteunitaspro vided by the manufacturer Do not att...

Страница 30: ...re also provided on a tag attached to one of the lower door brackets When first lighting the appliance it will take a few minutes for the gas line to purge itself of air Once purging is complete the p...

Страница 31: ...tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance...

Страница 32: ...Guidelines If there is smoke or soot present first ensure that the flames are not impinging on any of the panels If the panels are properly posi tioned and a sooting condition still exists increase t...

Страница 33: ...ES Make sure TOP and BOTTOM Nailing Flanges are attached to fireplace in the correct VERTI CAL position for Surround finish and the correct HORIZONTAL position for the wall finish material thickness s...

Страница 34: ...rd abuts lip Combustible Wall Finish Material Top Non Combustible Fiber Board provided with fireplace Wall Stud Insulation and combustible material NOT ALLOWED in clearance zones around vent component...

Страница 35: ...rez la t l commande et nettoyez la soigneuse ment pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure B Choisissez la langue qui es...

Страница 36: ...4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 pk 96K92 SV4 5SP Support Plate Vent Sections Rigid Listed Secure Vent Components Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square...

Страница 37: ...sedflex 77L89 SFKIT24S Horiz Termination forflex with24inch 610 mm compressedflex 77L90 SFKIT36S Horiz Termination forflex with36inch 914 mm compressedflex 77L91 SFKIT48S Horiz Termination forflex wit...

Страница 38: ...ever use substitute materials Use of non approved parts can result in poor performance and safety hazards and may void the warranty Parts with item numbers are illustrated on the next page Item No Des...

Страница 39: ...are those listed on the previous page LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODELS LDV42 LDV54 INSTALLATION INSTRUCTIONS 25 1 67 5 D B R E V 00 4 Power 120V Out Fan Aux O...

Страница 40: ...eserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for firepla...

Отзывы: