Page 34 of 36
506307-01
Issue 1207
Rollout Switch
This unit is equipped with a manual reset high temperature
sensor or rollout switch. In the unlikely event of a sustained
burner flame rollout, the rollout switch will shut off the flow of
gas by closing the gas valve. The switch is located inside the
gas burner area. Flame rollout can be caused by blockage of
the power vent system, a blocked heat exchanger, or improper
gas pressure or adjustment. If this event occurs, the unit will
not operate properly. The gas supply to the unit should be
shut off and
no attempt should be made to place it in
operation.
The system should be inspected by a qualified
service technician.
Safety Interlock Switch
The blower compartment door on your high efficiency gas
furnace is equipped with a safety interlock switch that will
automatically shut off your complete system (including
blower) once the door is removed. This is for your personal
safety. Be sure to check your furnace for proper operation
once the door or panel has been replaced. If the system
does not operate once the panel has been replaced, try
removing and replacing it once again. If the furnace still
does not operate, call your dealer for service.
Lubrication
Lubrication of the bearings in the circulating air blower motor
and the combustion blower motor is not recommended.
Burner Flame
While the furnace is in operation, observe the burner flames.
Compare these observations to Figure M-3 to determine if
proper flame adjustment is present. If your observations
indicate improper flame adjustment, call your authorized
service dealer for service.
Do not attempt to adjust flame!
Your service representative will perform this adjustment
correctly.
Typical Flame Appearance
Heat
Exchanger
Burner
Flame
(Blue Only)
Burner
Gas
Manifold
Figure M-3
REPAIR PARTS
The following repair parts are available from your local
distributor. When ordering parts, include the complete
furnace model number and serial number which are printed
on the rating plate located on the furnace.
Gas Control Group
Manifold
Orifice
Manifold Retention Plate
Ignition Wire
Burner
Gas Valve
Heat Exchanger Group
Primary Heat Exchanger
Transfer Tube
Flue Box
Burner Inlet Plate
Burner Box
Blower Group
Blower Assembly
Capacitor
Blower Housing
Blower Cutoff
Blower Motor
Blower Support
Blower Wheel
Inducer Group
Inducer Blower and Motor
Pressure switch
Electrical Group
Control Box
Ignition Control
Limit Switch
Transformer
Fan Timer Control Board
Rollout Switch
Содержание B050A3B
Страница 3: ...506307 01 Page 3 of 36 Issue 1207...
Страница 5: ...506307 01 Page 5 of 36 Issue 1207 FURNACE WIRING SPECIFICATIONS...
Страница 23: ...506307 01 Page 23 of 36 Issue 1207 SEQUENCE OF OPERATION DIRECT IGNITION SYSTEM CONTROL...
Страница 25: ...506307 01 Page 25 of 36 Issue 1207 WIRING DIAGRAM f0000321...
Страница 28: ...Page 28 of 36 506307 01 Issue 1207 NOTES...