DETAILED INSTALLATION STEPS

The appliance is shipped with all gas controls 

and components installed and pre-wired. 

1.  Remove the shipping carton, exposing the 

front glass door. 

2.  Pull out the two spring loaded latches secur-

ing the glass door (located under the firebox 

floor). Remove the door by tilting it outward 

at the bottom and lifting it up and off. Set 

the door aside protecting it from inadvertent 

damage. See 

Figures 50 and 51

 

on Page 

28

.

       WARNING 

Failure  to  position  the  parts  in 

accordance with these diagrams 

or failure to use only parts specifi-

cally approved with this appliance 

may result in property damage or 

personal injury.

       AVERTISSEMENT 

Risque  de  dommages  ou  de 

blessures  si  les  pièces  ne  sont 

pas  installées  conformément  à 

ces schémas et ou si des pièces 

autres que celles spécifiquement 

approuvées avec cet appareil sont 

utilisées.

Step 1. FRAMING

Frame these appliances as illustrated in 

Figures 

12 

and

  14 

on

  Pages  10 

and

  12 

(Figure  14 

applies to corner framing installations only).  

All framing details must allow for a minimum 

clearance to combustible framing members as 

shown in 

Table 5 on Page 8

.

If the appliance is to be elevated above floor 

level,  a  solid  continuous  platform  must  be 

constructed below the appliance. 

Headers  may  be  in  direct  contact  with  the 

appliance  top  spacers  but  must  not  be  sup-

ported by them or notched to fit around them.  

All construction above the appliance must be 

self-supporting, DO NOT use the appliance for 

structural support.

The fireplace should be secured to the side fram-

ing members using the unit's nailing flanges on 

each side of the fireplace front (see 

Figure 11

)

Use 8d nails or their equivalent. 

Figure 11

Left Side Front Corner of Fireplace Shown

(Right Side Requirements the Same)

Unit Being Secured By Its Nailing

Flanges To The Framing

Frame the opening to the exact dimensions 

specified in the framing details in this manual.

Use Top Flange For

5/8” Thick Drywall

Use Center Flange For 

1/2” Thick Drywall

Use Bottom Flange

For Flush Mount

TYPICAL INSTALLATION SEQUENCE

The typical sequence of installation is outlined 

below.    However,  each  installation  is  unique 

and  may  result  in  variations  to  the  steps 

described. 

See the page numbers references in the follow-

ing steps for detailed procedures.

Step 1.  (

Page  9

)    Construct  the  appliance 

framing.  Position the appliance within 

the  framing  and  secure  with  nailing 

brackets.

Step 2.  (

Page  12

)  Route  gas  supply  line  to 

appliance location.

Step 3.  (

Page 13

) Install the vent system and 

exterior termination. 

Step 4.  (

Page 23

Field Wiring 

.25

 

a. Millivolt Appliances – The operating 

control switch is  factory installed.

.25

 

b. Electronic Appliances – Connect 120 

Vac electrical power to the appliance 

receptacle.  

Step 5.  (

Page 24

)  Install blower kit (optional 

equipment).

Step 6.  (

Page  24

)  Make  connection  to  gas 

supply.

Step 7.  (

Page  25

)  Verify  appliance  opera-

tion. 

BEFORE PROCEEDING TO 

STEP 8

, INSTALL 

A  FIREBOX  LINER  KIT  PER  INSTRUCTIONS 

PROVIDED  IN  THE  KIT  (REQUIRED  -  SOLD 

SEPARATELY).

Step 8.  (

Page 26

 Install the logs and glowing 

embers.

Step 9.  (

Page 28

 Install glass door assem-

bly.

Step 10. (

Page  29

)  Adjust  burner  to  ensure 

proper flame appearance.

Step 11. 

(Page 31)

 Attach Safety in Operation 

Warnings.

f i r e - p a r t s . c o m

Содержание ADAGIO-EN

Страница 1: ...isseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur...

Страница 2: ...ssories that will require electrical power are to be installed the electrical power must be provided at the time of appliance installation The Electronic appliances have an electronic intermittent pil...

Страница 3: ...Electrical Code CSA C22 1 latest edition Provide adequate clearances around air open ings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of th...

Страница 4: ...edition NOTE Flame appearance will diminish 4 per thousand feet Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Nat Gas drill size inches Propane drill size inches Adagio 000 51 H0922...

Страница 5: ...and wherever cold air could enter the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Gas line ho...

Страница 6: ...tional Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CSA B149 1 in Canada Vertical Vent Termination Clearances Terminatemultipleventterminationsaccording to the installation cod...

Страница 7: ...r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i...

Страница 8: ...insulate the space between the appliance and the area above it Shelf Height see table Shelf Above Fireplace Top Vent Drywall Header Top Spacers 4 102mm u4 clearance is required above the elbow for ins...

Страница 9: ...upport Thefireplaceshouldbesecuredtothesidefram ingmembersusingtheunit snailingflangeson each side of the fireplace front see Figure 11 Use 8d nails or their equivalent Figure 11 Left Side Front Corne...

Страница 10: ...nce below the vent This does not include the suggested 1 4 rise per foot for horizontal runs With the facade installed required sold separately the appliancebasewillneedtobeelevatedaminimumof3 4 above...

Страница 11: ...o change or discontinuance without notice With the facade installed required sold separately the appliance base will need to be elevated a minimum of 3 4 above the floor to allow for the proper fit of...

Страница 12: ...sooting severe delayed ignition orothermalfunctions Anydamageresulting from an improper installation such as this is not covered under the limited warranty Never use galvanized or plastic pipe Refer...

Страница 13: ...on Page 2 These fireplaces must be vented directly to the outside The vent system may not service multiple ap pliances and must never be connected to a flue servingasolidfuelburningappliance The vent...

Страница 14: ...5 7 6 5 2 6 5 0 0 3 0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0...

Страница 15: ...of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer...

Страница 16: ...ulk ing or mastic around the circumference of the joint to provide a water tight seal Figure 22 Storm Collar Flashing Figure 23 If the vent system extends more than 5 1 5 m above the roof flashing sta...

Страница 17: ...VF uCeiling Firestop Spacer SV4 5VF u Ceiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4...

Страница 18: ...nces for elbows as indicated in Figure 20 on Page 16 Maintain a minimum 1 25 mm clearance to combustibles on the vertical sections Clear ances for the horizontal runs are 3 76 mm on top 1 25 mm on sid...

Страница 19: ...vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as describedinStepB Assembletheventsystem topointwheretheterminusofthelastse...

Страница 20: ...1 V to 5 H ratio up to a maximum horizontal run of 20 feet except for installations where an elbow is the only vertical vent section in the system see Figure 30 AN ELBOW IS ACCEPTABLE AS 1 FOOT OF VER...

Страница 21: ...f 20 feet An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only vertical component in the system See Figure 30 V H H1 V1 Wall Firestop Spacer SV4 5HF Ceiling Firestop Spa...

Страница 22: ...ck out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent...

Страница 23: ...U P 2 1 N E E R G BLUE 20 BLACK 16 WHITE FIELD WIRED FACTORY WIRED Turn The Appliance Mounted ON OFF Burner Control Switch To The OFF Position If An Optional Control Switch Is Installed Optional Blowe...

Страница 24: ...ns provided with the kit If the blower kit is to be installed at the time of installationoratalaterdate themainpowersup plyandwallswitchmustbeinstalledatthetimeof installation This will require that t...

Страница 25: ...ions provided in the Care and Operation Manual For piezo igniter location see Figure 40 on Page 24 millivolt appliances only Note LightingInstructionsarealsofoundonthe literature tag tied to the gas p...

Страница 26: ...installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appli...

Страница 27: ...ole on the bottom of log D over pin 3 4 Place the right front log E as shown in Figure 47 Position the hole on the bottom of log E over pins 4 and 5 6 Ember Placement Separate the Embers rockwool into...

Страница 28: ...ner when installing the door Take care when seat ing the top door gasket so that it is not obstructed by the refractory panel If the doorfeelsrestrictedwhenlatching thetop door gasket may not be prope...

Страница 29: ...rod and associated adjustable air shutter is patented technology Flame ad justments can be made quickly and accurately to taste without the need of disassembling the appliance and waiting for 30 minut...

Страница 30: ...equirements Wall Details Complete finished interior wall To install the appliance facing flush with the finished wall position framework to accommodate the thickness of the finished wall Figure 54 u 4...

Страница 31: ...ntrelasetiquetasadhesivasmultiling es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeel...

Страница 32: ...750 247M Vent Sections ListedSecureFlex Components Cat No Model Description These termination kits include firestop spacer gear clamps and flex adaptor H1969 SF4 5HT 2 HorizontalSquareTermina tion wit...

Страница 33: ...anufacturer s instructions and all applicable codes and requirementsoftheauthorityhavingjurisdiction Iftheinformationinthese instructionisnotfollowedexactly afire explosionorproductionofcarbon monoxid...

Страница 34: ...t Orifice Thermopile on millivolt pilot assem blies only Millivolt Electronic Pilot Assemblies SIT Electronic Pilot Pilot Orifice B Retrieve the burner and slide the venturi tube over the orifice see...

Страница 35: ...35 NOTES fire parts com...

Страница 36: ...oducts reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fir...

Отзывы: