background image

28

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Step 9.INSTALLATION AND REMOVAL OF 

GLASS DOOR

Figure 5

1

 - Glass Door Removal

Door 

Assembly

These  are  direct-vent  appliances.  They  are 

designed to operate only when the front glass 

enclosure panel is installed.  Generally the front 

glass enclosure panel should not be removed 

except to gain access to the components within 

the firebox

.

During  this  appliance  checkout  and  adjust-

ment period, a potential safety hazard exists 

-  EXERCISE  EXTREME  CAUTION  to  prevent 

the occurrence of any burn injuries from the 

exposed  flames  or  hot  surfaces.    Also  note, 

that  while  the  front  glass  enclosure  panel  is 

removed, the flame appearance will appear to 

be smaller than normal.

Removing Glass Enclosure Panel

(see 

Figures 50 and 51)

1. Remove  the  facade  assembly  by  lifting  it 

up  and  toward  you  (see  the  installation 

instruction sheet provided with the facade 

for additional information).

2. Locate the two (2) latches at the top of the 

control  compartment  (see 

Figure  50

).  To 

disengage the two latches, pull the spring-

loaded latches forward then down as shown 

in 

Figure 50

.

3. Swing the bottom of the door out (see 

Figure 

51

) and raise it slightly to lift the top flange of 

the door frame away from the appliance.

Installing Glass Enclosure Panels

(see 

Figures 50 and 51)

Note: This appliance is not approved for opera-

tion without a log set (provided) or a firebox 

liner kit installed (sold separately). 

1. Visually inspect the gasket on the backside 

of the glass panel. The gasket surface must 

be  clean,  free  of  irregularities  and  seated 

firmly.

 

IMPORTANT NOTE:  Be very careful not to 

damage the refractory firebox liner when 

installing the door.  Take care when seat-

ing  the  top  door  gasket  so  that  it  is  not 

obstructed by the refractory panel. If the 

door feels restricted when latching, the top 

door gasket may not be properly seated.

2. Position the glass enclosure panel in front 

of the firebox opening at a 45 degree angle 

and engage the top flange over the lip at the 

top of the firebox opening (read important 

note above) (

see Figure 51

)

.

3. Swing the glass enclosure panel down and 

back.    Ensure  the  gasket  seats  evenly  as 

the panel draws shut.  Close the latches to 

secure the panel.

4. Reinstall the facade assembly.

Figure 5

0

 - Glass Door Latches

Spring-Loaded Latches

Pull forward then down to release

Pull Latches 

Forward

Only doors certified with the appliance 

shall be used.

Seules  des  portes  certifiées  pour  cet 

appareil doivent être utilisées.

CAUTION: DO NOT abuse glass door by 

striking or slamming shut.

A required firebox liner kit must be installed 

prior to installing the glass door.  Install the 

liner per instructions provided in kit. 

       WARNING 

 

Do not attempt to substitute the 

materials used on these doors, 

or replace cracked or broken 

glass. 

• Handle this glass with extreme 

care!  Glass  is  susceptible  to 

damage  – Do  not  scratch  or 

handle roughly while reinstall-

ing the glass door frame.

• The glass door(s) of this appli-

ance must only be replaced as 

a  complete  unit  as  provided 

by the manufacturer.  Do not 

attempt  to  replace  broken, 

cracked or chipped glass sepa-

rately. 

 

Do  not  attempt  to  touch  the 

front enclosure glass with your 

hands while the fireplace is in 

use.

       WARNING 

Do not operate appliance with 

the glass front removed, cracked 

or broken.

       AVERTISSEMENT 

Ne pas utiliser l'appareil si le 

panneau frontal en verre n'est 

pas  en  place,  est  craqué  ou 

brisé.  

Note:  When installing the glass door, ensure 

the spacing on both sides are equal.

f i r e - p a r t s . c o m

Содержание ADAGIO-EN

Страница 1: ...isseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur...

Страница 2: ...ssories that will require electrical power are to be installed the electrical power must be provided at the time of appliance installation The Electronic appliances have an electronic intermittent pil...

Страница 3: ...Electrical Code CSA C22 1 latest edition Provide adequate clearances around air open ings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of th...

Страница 4: ...edition NOTE Flame appearance will diminish 4 per thousand feet Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Nat Gas drill size inches Propane drill size inches Adagio 000 51 H0922...

Страница 5: ...and wherever cold air could enter the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Gas line ho...

Страница 6: ...tional Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CSA B149 1 in Canada Vertical Vent Termination Clearances Terminatemultipleventterminationsaccording to the installation cod...

Страница 7: ...r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i...

Страница 8: ...insulate the space between the appliance and the area above it Shelf Height see table Shelf Above Fireplace Top Vent Drywall Header Top Spacers 4 102mm u4 clearance is required above the elbow for ins...

Страница 9: ...upport Thefireplaceshouldbesecuredtothesidefram ingmembersusingtheunit snailingflangeson each side of the fireplace front see Figure 11 Use 8d nails or their equivalent Figure 11 Left Side Front Corne...

Страница 10: ...nce below the vent This does not include the suggested 1 4 rise per foot for horizontal runs With the facade installed required sold separately the appliancebasewillneedtobeelevatedaminimumof3 4 above...

Страница 11: ...o change or discontinuance without notice With the facade installed required sold separately the appliance base will need to be elevated a minimum of 3 4 above the floor to allow for the proper fit of...

Страница 12: ...sooting severe delayed ignition orothermalfunctions Anydamageresulting from an improper installation such as this is not covered under the limited warranty Never use galvanized or plastic pipe Refer...

Страница 13: ...on Page 2 These fireplaces must be vented directly to the outside The vent system may not service multiple ap pliances and must never be connected to a flue servingasolidfuelburningappliance The vent...

Страница 14: ...5 7 6 5 2 6 5 0 0 3 0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0...

Страница 15: ...of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer...

Страница 16: ...ulk ing or mastic around the circumference of the joint to provide a water tight seal Figure 22 Storm Collar Flashing Figure 23 If the vent system extends more than 5 1 5 m above the roof flashing sta...

Страница 17: ...VF uCeiling Firestop Spacer SV4 5VF u Ceiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4...

Страница 18: ...nces for elbows as indicated in Figure 20 on Page 16 Maintain a minimum 1 25 mm clearance to combustibles on the vertical sections Clear ances for the horizontal runs are 3 76 mm on top 1 25 mm on sid...

Страница 19: ...vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as describedinStepB Assembletheventsystem topointwheretheterminusofthelastse...

Страница 20: ...1 V to 5 H ratio up to a maximum horizontal run of 20 feet except for installations where an elbow is the only vertical vent section in the system see Figure 30 AN ELBOW IS ACCEPTABLE AS 1 FOOT OF VER...

Страница 21: ...f 20 feet An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only vertical component in the system See Figure 30 V H H1 V1 Wall Firestop Spacer SV4 5HF Ceiling Firestop Spa...

Страница 22: ...ck out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent...

Страница 23: ...U P 2 1 N E E R G BLUE 20 BLACK 16 WHITE FIELD WIRED FACTORY WIRED Turn The Appliance Mounted ON OFF Burner Control Switch To The OFF Position If An Optional Control Switch Is Installed Optional Blowe...

Страница 24: ...ns provided with the kit If the blower kit is to be installed at the time of installationoratalaterdate themainpowersup plyandwallswitchmustbeinstalledatthetimeof installation This will require that t...

Страница 25: ...ions provided in the Care and Operation Manual For piezo igniter location see Figure 40 on Page 24 millivolt appliances only Note LightingInstructionsarealsofoundonthe literature tag tied to the gas p...

Страница 26: ...installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appli...

Страница 27: ...ole on the bottom of log D over pin 3 4 Place the right front log E as shown in Figure 47 Position the hole on the bottom of log E over pins 4 and 5 6 Ember Placement Separate the Embers rockwool into...

Страница 28: ...ner when installing the door Take care when seat ing the top door gasket so that it is not obstructed by the refractory panel If the doorfeelsrestrictedwhenlatching thetop door gasket may not be prope...

Страница 29: ...rod and associated adjustable air shutter is patented technology Flame ad justments can be made quickly and accurately to taste without the need of disassembling the appliance and waiting for 30 minut...

Страница 30: ...equirements Wall Details Complete finished interior wall To install the appliance facing flush with the finished wall position framework to accommodate the thickness of the finished wall Figure 54 u 4...

Страница 31: ...ntrelasetiquetasadhesivasmultiling es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeel...

Страница 32: ...750 247M Vent Sections ListedSecureFlex Components Cat No Model Description These termination kits include firestop spacer gear clamps and flex adaptor H1969 SF4 5HT 2 HorizontalSquareTermina tion wit...

Страница 33: ...anufacturer s instructions and all applicable codes and requirementsoftheauthorityhavingjurisdiction Iftheinformationinthese instructionisnotfollowedexactly afire explosionorproductionofcarbon monoxid...

Страница 34: ...t Orifice Thermopile on millivolt pilot assem blies only Millivolt Electronic Pilot Assemblies SIT Electronic Pilot Pilot Orifice B Retrieve the burner and slide the venturi tube over the orifice see...

Страница 35: ...35 NOTES fire parts com...

Страница 36: ...oducts reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fir...

Отзывы: