When connecting electrical power and control
wiring to the unit, waterproof type connectors
must be used so that water or moisture cannot
be drawn into the unit during normal operation

.

 CAUTION

Power supply to the unit must be N.E.C. Class 1, and must
comply with all applicable codes. A fused disconnect switch
should be field provided for the unit. The switch must be
separate from all other circuits.

Figure 5

Electrical Access

Heater Power Entry

Thermostat

Entry

Line Voltage

Entry

Unit must be grounded in accordance with
national and local codes. Failure to ground unit
properly can result in personal injury or death.

  WARNING

Figure 6

Typical Wiring Connections

R

R

C

C

C

C

R

R

L2

L1

Y

Y

Y1

Y

L1

L2

L3

POWER WIRING

208/230-1-60

(90°C MIN. WIRE)

POWER WIRING

24V CONTROL WIRING

(NEC CLASS 2)

TYPICAL WIRING CONNECTION

1 PHASE

GROUND
SCREW

THERMOSTAT

OUTDOOR UNIT

THERMOSTAT

OUTDOOR UNIT

GROUND
SCREW

POWER WIRING

200/230-3-60, 460/575-3-60

(90°C MIN. WIRE)

24V CONTROL WIRING

(NEC CLASS 2)

POWER WIRING

TYPICAL WIRING CONNECTION

3 PHASE

* W1, W2 CAN BE USED TO STAGE ELECTRIC

HEAT ACCESSORY ON 15, 20 & 25 KW MODELS.

* 5 & 10 KW HEATER ACCESSORY FUNCTION OFF

W1 ONLY.

* W1, W2 CAN BE USED TO STAGE ELECTRIC

HEAT ACCESSORY ON 15, 20 & 25 KW MODELS.

* 10 KW HEATER ACCESSORY FUNCTION OFF

W1 ONLY.

ECONOMIZER

NOT

INSTALLED

ECONOMIZER

W1

W

W

W1

G

G

G

G

W2

Y2

W2

O

O

O

O

BLUE

WHITE

YELLOW

ORANGE

GREEN

BLACK

Do not connect        connections except when

required by the indoor thermostat. Refer to the

thermostat installation instructions.

C

CAUTION

Do not connect        connections except when

required by the indoor thermostat. Refer to the

thermostat installation instructions.

C

CAUTION

If any of the wire supplied with the unit must be replaced,
replacement wire must be of the type shown on the wiring
diagram. Electrical wiring must be sized to carry minimum
circuit ampacity marked on the unit. 

Use copper conduc-

tors only.

 Each unit must be wired with a separate branch

circuit and be properly fused.

Содержание (2/4)SH13

Страница 1: ...ion of this appliance must conform to the requirements of the National Fire Protection Association the National Electrical Code ANSI NFPA No 70 latest edition in the United States the Canadian Electri...

Страница 2: ...es must also be observed The unit must not be installed with any ductwork in the outdoor air stream The outdoor fan is not designed to operate against any additional static pressure Location The unit...

Страница 3: ...h a 3 4 FPT cou pling for condensate line connection Plumbing must conform to local codes Use a sealing compound on male pipe threads The condensate drain line must be properly trapped and routed to a...

Страница 4: ...free from duct flange 3 Slide duct cover out the side duct opening Filters Air filters are to be used with this heating cooling unit Filters are not factory supplied in the unit However a filter frame...

Страница 5: ...T OUTDOOR UNIT GROUND SCREW POWER WIRING 200 230 3 60 460 575 3 60 90 C MIN WIRE 24V CONTROL WIRING NEC CLASS 2 POWER WIRING TYPICAL WIRING CONNECTION 3 PHASE W1 W2 CAN BE USED TO STAGE ELECTRIC HEAT...

Страница 6: ...test should be conducted with each appliance while the other appliances connected to the common venting system are not in operation 1 Seal any unused openings in the common venting system 2 Visually i...

Страница 7: ...F or cooler the thermostat contacts close and send a signal to the defrost control board to start the defrost timing It also terminates defrost when the liquid line warms up to 70 F Defrost Control Th...

Страница 8: ...optional can be connected to the HI PS terminals see Figure 8 on page 7 During a single demand cycle the defrost control will lock out the unit after the fifth time that the circuit is interrupted by...

Страница 9: ...t conditions of 82 F outdoor and 80 F indoor dry bulb 67 F wet bulb If subcooling measured deviates from values found in Table 4 refrigerant charge should be adjusted accordingly for maximum performan...

Страница 10: ...and outdoor fan and vent motors are permanently lubricated and require no maintenance Outdoor Coil Dirt and debris should not be allowed to accumulate on the outdoor coil surface or other parts in the...

Страница 11: ...e Because the pressure switches are monitored only when Y1 Input is active the code for pressure switch open will not be seen when Y1 is off Instead the Normal Operation or Anti Short Cycle Lockout co...

Страница 12: ...f and excludes all other warranties express or implied The warrantor does not authorize any person to provide any other warranty or to assume for it any further obligation in connection with the warra...

Отзывы: