background image

Page 12

# 48369K005

Limited Warranty

August 1, 1997

This warranty gives you specific legal rights and you may have other rights

which vary from state/province to state/province.

Subject to the limitations stated in this warranty, we warrant to the first buyer for use the residential heating, cooling, or heat pump unit,
when installed, operated, and maintained as required by this warranty, to be free of defects in workmanship or material for a period of
5 years in residential installations (1 year in non-residential installations) from the time of installation. We will replace any defective
component without cost or expense to you except for the costs of delivery and labor for removal and replacement of the defective
component.

These (2/4)SH13 package heat pump units carry a 5-year limited warranty on the compressor.  Limited warranties apply
to the original owner in private owner-occupied residences.

Warranty Begins

The warranty period begins when the installation is complete and the product is ready to operate. You must be able to verify this date
whenever a warranty claim is made. Original bill of sale, installer’s invoice, or other similar document will suffice. If the beginning date
cannot be verified, we will consider warranty coverage to begin 6 months after the date the product was shipped from our factory.

Limitations on Implied Warranties

Implied warranties of merchantability or, to the extent applicable, fitness for a particular purpose are limited to 5 years, the same duration
as the basic limited written warranty provided herein. Some states/provinces do not allow limitations on how long an implied warranty of
merchantability or fitness lasts, so the above limitations or exclusions may not apply to you.

Only Warranty

This written Limited Warranty is the only warranty made by the warrantor; this warranty is in lieu of and excludes all other warranties,
express or implied. The warrantor does not authorize any person to provide any other warranty or to assume for it any further
obligation in connection with the warranted product.

What is NOT Covered

1. Cabinets or cabinet pieces.
2. Normal maintenance items such as filters, fan belts, fuses, or other consumable items.
3. Damage caused by misuse, failure to maintain properly, accidents, or acts of God.
4. External wiring, piping, venting, or attachment of accessory products not integral to our product, including without limitation,

humidifier, air cleaner, vent damper, thermostat, or other mechanical devices not manufactured by the warrantor.

5. Products that have been operated in a corrosive atmosphere where a concentration of acids, halogenated hydrocarbons,

or other corrosive elements causes deterioration to metal surfaces or integral components. NOTE: Operation in a corrosive
atmosphere is considered abuse and voids this warranty.

6. Products that have NOT been installed in accordance with our published installation instructions, applicable local, state/

provincial, or national codes, ACCA published standards.

7. Products that have NOT been installed by competent, qualified installers.
8. Products that have been moved from their original place of installation.

Warranty on Replacement Components

Any replacement component furnished by us will assume the remaining (unused) portion of the Limited Warranty.

Consequential Damages

The warrantor shall not be responsible for any consequential damages caused by any defect in the product. Some state/provinces do
not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This product must be installed, used, and cared for in accordance with the instruction manual. You are responsible for required periodic
maintenance or service, such as changing or cleaning of air filters and lubrication or cleaning of components. Failure to properly install,
operate, or maintain your unit voids this warranty.

Содержание (2/4)SH13

Страница 1: ...ion of this appliance must conform to the requirements of the National Fire Protection Association the National Electrical Code ANSI NFPA No 70 latest edition in the United States the Canadian Electri...

Страница 2: ...es must also be observed The unit must not be installed with any ductwork in the outdoor air stream The outdoor fan is not designed to operate against any additional static pressure Location The unit...

Страница 3: ...h a 3 4 FPT cou pling for condensate line connection Plumbing must conform to local codes Use a sealing compound on male pipe threads The condensate drain line must be properly trapped and routed to a...

Страница 4: ...free from duct flange 3 Slide duct cover out the side duct opening Filters Air filters are to be used with this heating cooling unit Filters are not factory supplied in the unit However a filter frame...

Страница 5: ...T OUTDOOR UNIT GROUND SCREW POWER WIRING 200 230 3 60 460 575 3 60 90 C MIN WIRE 24V CONTROL WIRING NEC CLASS 2 POWER WIRING TYPICAL WIRING CONNECTION 3 PHASE W1 W2 CAN BE USED TO STAGE ELECTRIC HEAT...

Страница 6: ...test should be conducted with each appliance while the other appliances connected to the common venting system are not in operation 1 Seal any unused openings in the common venting system 2 Visually i...

Страница 7: ...F or cooler the thermostat contacts close and send a signal to the defrost control board to start the defrost timing It also terminates defrost when the liquid line warms up to 70 F Defrost Control Th...

Страница 8: ...optional can be connected to the HI PS terminals see Figure 8 on page 7 During a single demand cycle the defrost control will lock out the unit after the fifth time that the circuit is interrupted by...

Страница 9: ...t conditions of 82 F outdoor and 80 F indoor dry bulb 67 F wet bulb If subcooling measured deviates from values found in Table 4 refrigerant charge should be adjusted accordingly for maximum performan...

Страница 10: ...and outdoor fan and vent motors are permanently lubricated and require no maintenance Outdoor Coil Dirt and debris should not be allowed to accumulate on the outdoor coil surface or other parts in the...

Страница 11: ...e Because the pressure switches are monitored only when Y1 Input is active the code for pressure switch open will not be seen when Y1 is off Instead the Normal Operation or Anti Short Cycle Lockout co...

Страница 12: ...f and excludes all other warranties express or implied The warrantor does not authorize any person to provide any other warranty or to assume for it any further obligation in connection with the warra...