background image

# 48369K005

Page 11

Figure 9

Wiring Diagram

P/N 48349-001

208/230V

-1-60

G

W1

CR

O

BLK

RED

YEL

RED

CONT

A

C

T

O

R

THERMOST

A

T

HIGH PRESSURE

SWITCH

(IF USED)

L1

T1

T2

L2

C

H

F

CONDENSER

F

AN MO

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

DU

AL

CAP

A

CIT

OR

COMPRESSOR

TRANSFORMER

C

S

R

WHT

L2

L1

BLK

BRN

PUR

RED

RED

BLK

208V

240V

24V

INDOOR

BLO

WER

M

OTO

R

NO

TE:

IF ANY OF

THE ORIGINAL

WIRE IS REPLA

CED

THE

SAME SIZE AND

TYPE

WIRE

MUST BE USED

.

USE

COPPER CONDUCT

OR ONL

Y

,

MIN 75°C

WIRE.

LINE

V

O

LT

A

GE FIELD INST

ALLED

.

W

ARNING-

ELECTRIC SHOCK HAZARD

.

UNIT

MUST BE GR

OUNDED

IN A

CCORD

ANCE

WITH

NA

TIONAL AND LOCAL CODES

.

S4

S1

K1

T1

B3

B4

K1-2

C12

B1

K1-1

BLU

YEL

C4

CAP

A

CIT

OR

H

M

L

C

SEE CHAR

T

FOR

WIRING

M

OTO

R

SPEED

T

APS

NO

NC

C

P-3

BLO

WER

CONTR

OL

A15

NC

C

CMC1

BLK

C

G

XFMR-R

R

XFMR-C

W1

C

L

R

O

Y1

FA

N

O-OUT

LO-PS

DF

HI-PS

COMMON

Y1 OUT

2

2

CMC1

S6

L1

24

V

FUSE

Y

A15

BLO

WER

CONTR

OL

W2

RED

YEL

BLU

WHT

GRN

ORN

RED

BLU

BLU

YEL

BLU

DIAGNOSTIC DISPLA

Y

Note:

Because the pressure s

witches are monitored only when "Y1" (Input) is activ

e

, the code f

o

r

pressure s

witch open will not be seen when "Y1" is off

.

Instead, the

“Nor

mal Oper

ation" or

“Anti-Shor

t Cycle Loc

k

out”

code will be seen.

When a pressure s

witch opens and causes a shor

t cycle loc

k

out, the

pressure

s

witch-open code will be seen until it closes

, then the shor

t cycle loc

k

out code

will flash unless it has already e

xpired.

W1 &

W2 CAN BE USED

T

O

 ST

A

G

E

ELECTRIC HEA

T

A

CCESSOR

Y ON 15 & 20KW MODELS

.

5, 7.5,

& 10KW HEA

TER A

CCESSORIES FUNCTION

OFF

W1 ONL

Y

.

BLK

BLK

DEFR

OST

CONTR

OL

BLU

WHT

REVERSING

VA

LV

E

DEFR

OST

T'ST

A

T

DEFR

OST CONTR

OL

P-1

P-2

P-4

P-6

P-5

CONNECTION MUST BE JUMPERED

WHEN PRESSURE SWITCH IS NO

T USED

.

2

Unit

F

a

c

tor

y

S

hipped

Se

tt

in

g

s

C

ooling

Input

(B

L

K

)

24

LO

W

30

MED

36

HIGH

42

LO

W

48

MED

60

HIGH

Mode

G

reen

LE

D

(D

S

2

)

Re

d

L

ED

(D

S1

)

No

P

o

w

e

r

to

Board

O

ff

Off

Nor

m

al

Oper

ation/

P

o

w

e

r

to

Board

Sim

u

ltaneous

Slo

w

Flash

Anti-Shor

t

C

ycle

Loc

k

out

Alter

nating

S

lo

w

F

lash

Lo

w

P

ressure

Switch

F

ault

Off

Slo

w

Flash

Lo

w

P

ressure

Switch

Loc

k

out

Off

O

n

High

Pressure

Switch

F

ault

Slo

w

Flash

Off

High

Pressure

Switch

Loc

k

out

On

Off

L

M

HC

BLOWER SPEED CHAR

T

Содержание (2/4)SH13

Страница 1: ...ion of this appliance must conform to the requirements of the National Fire Protection Association the National Electrical Code ANSI NFPA No 70 latest edition in the United States the Canadian Electri...

Страница 2: ...es must also be observed The unit must not be installed with any ductwork in the outdoor air stream The outdoor fan is not designed to operate against any additional static pressure Location The unit...

Страница 3: ...h a 3 4 FPT cou pling for condensate line connection Plumbing must conform to local codes Use a sealing compound on male pipe threads The condensate drain line must be properly trapped and routed to a...

Страница 4: ...free from duct flange 3 Slide duct cover out the side duct opening Filters Air filters are to be used with this heating cooling unit Filters are not factory supplied in the unit However a filter frame...

Страница 5: ...T OUTDOOR UNIT GROUND SCREW POWER WIRING 200 230 3 60 460 575 3 60 90 C MIN WIRE 24V CONTROL WIRING NEC CLASS 2 POWER WIRING TYPICAL WIRING CONNECTION 3 PHASE W1 W2 CAN BE USED TO STAGE ELECTRIC HEAT...

Страница 6: ...test should be conducted with each appliance while the other appliances connected to the common venting system are not in operation 1 Seal any unused openings in the common venting system 2 Visually i...

Страница 7: ...F or cooler the thermostat contacts close and send a signal to the defrost control board to start the defrost timing It also terminates defrost when the liquid line warms up to 70 F Defrost Control Th...

Страница 8: ...optional can be connected to the HI PS terminals see Figure 8 on page 7 During a single demand cycle the defrost control will lock out the unit after the fifth time that the circuit is interrupted by...

Страница 9: ...t conditions of 82 F outdoor and 80 F indoor dry bulb 67 F wet bulb If subcooling measured deviates from values found in Table 4 refrigerant charge should be adjusted accordingly for maximum performan...

Страница 10: ...and outdoor fan and vent motors are permanently lubricated and require no maintenance Outdoor Coil Dirt and debris should not be allowed to accumulate on the outdoor coil surface or other parts in the...

Страница 11: ...e Because the pressure switches are monitored only when Y1 Input is active the code for pressure switch open will not be seen when Y1 is off Instead the Normal Operation or Anti Short Cycle Lockout co...

Страница 12: ...f and excludes all other warranties express or implied The warrantor does not authorize any person to provide any other warranty or to assume for it any further obligation in connection with the warra...

Отзывы: