Page 2
Installation Clearances
See
NOTES
See NOTES
See NOTES
See
NOTES
CONTROL
BOX
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on
one of the sides adjacent to the control box.
Clearance to one of the other three sides must be
36 in. (914 mm)
Clearance to one of the remaining two sides may be
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
Model Number Identification
16
HP
X
–
036
- 230
A
0 1
Nominal SEER
Unit Type
HP = Heat Pump
Refrigerant
X = R-410A
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
Voltage
230 = 208/230V-1phase-60hz
Ratings Revision Level
Regional Standards
– (dash) = All Regions
Revision Number