background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

4

LENNOX HEARTH PRODUCTS  •  RHAPSODY™ LINEAR DIRECT-VENT GAS FIREPLACES (MODELS RHAP42N & RHAP54N)  •  INSTALLATION INSTRUCTIONS

gENERAL 

INfORMATION

INTROdUCTION

LENNOX  HEARTH  PRODUCTS   Rhapsody™ 

model  fireplaces  are  direct-vent  (top  vent 

only),  sealed  combustion,  air-circulating  gas 

fireplaces  designed  for  residential,  manufac-

tured home and commercial applications.

Direct-vent appliances operate with the com-

bustion  chamber  isolated  from  the  indoor 

environment. All air for combustion is brought 

in  from  the  outside,  and  exhaust  gases  are 

vented through the same direct-vent, coaxial 

(intake/exhaust) vent system.

These  appliances  are  designed  to  operate 

on natural or propane gas 

only

. The use of 

other fuels or fuel combinations will degrade 

the  performance  of  this  system,  may  be 

dangerous, and may void the warranty.

The electronic system is switchable between 

standing  and  intermittent  pilot  modes 

(see 

Figure 15)

.

The Total Comfort Control Remote  Control 

System is included with all models and provides 

remote operation of several fireplace functions 

(manual adjustment of the gas valve settings is 

not possible). 

See 

Page 26 

for details.

Electrical power (120V AC line voltage) is rec-

ommended to operate the fireplace; however, 

“AA” batteries can be used for full-time opera-

tion or as a backup in case of a power outage.

Note: Batteries will operate the gas valve 

OPEN/CLOSE and pilot ON/OFF functions 

only. Electrical power (120V AC line volt-

age) is required to operate the following 

optional  components

  (bat teries  will  not 

power any of these options):
•  Blower Kit
•  Power Vent System
•  Panel Backlighting Kit

LISTINg INfORMATION

These appliances comply with National Safety 

Standards and are tested and listed by Intertek 

(Report  No.  100404899PRT-001)  to  ANSI 

Z21.88 (in Canada, CSA-2.33), and CAN/CGA-

2.17-M91 (CSA P4.1) in both USA and Canada, 

as vented gas fireplace heaters.

These  appliances  are  listed  by  Intertek  for 

installation in bedrooms, aftermarket mobile 

homes, and manufactured homes.

COdES

Installation must conform to local codes or, in 

the absence of local codes, with the 

National 

Fuel Gas Code, ANSI Z223.1/NFPA 54, latest 

edition

  (in  Canada,  the  current  CAN/CGA-

B149.1 installation code).

The appliance, when installed, must be electri-

cally grounded and wired in accordance with 

local codes, or, in the absence of local codes, 

with the 

National Electrical Code, ANSI/NFPA 

70,  latest  edition, 

or  the 

Canadian  Electrical 

Code, CSA C22.1, latest edition

.

MANUfACTUREd HOME 

REqUIREMENTS

This appliance may be installed in an aftermar-

ket permanently located, manufactured home 

and must be installed in accordance with the 

manufacturer's instructions. 

Cet  appareil  peut  être  installé  cómme  du 

matéri-el d'origine dans une maison préfab-

riquée (É.U. seulement) ou mobile et doit être 

installé selon les instructions du fabricant. 

This appliance is only for use with the type of gas 

indicated on the rating plate.  This appliance is 

not convertible for use with other gases, unless 

a certified kit is used.

Cet  appareil  doit  être  utilisé  uniquement 

avec le type de gaz indiqué sur la plaque 

signalétique. Cet appareil ne peut être con-

verti à d'autres gaz, sauf si une trousse de 

conversion est utilisée.

CAUTION:  Ensure  that  the  cross  mem-
bers  are  not  cut  or  weakened  during 
installation.  The  structural  integrity  of 
the manufactured home floor, wall, and 
ceiling / roof must be maintained. 

CAUTION: This appliance must be ground-
ed  to  the  chassis  of  the  manufactured 
home in accordance with local codes or 
in the absence of local codes, with the 
National Electrical Code ANSI / NfPA 70 
- latest edition or the Canadian Electrical 
Code CSA C22.1 - latest edition. 

EffICIENCIES

fireplace 

Model

Natural gas

Propane

(field-converted)

AfUE* Energuide 

(P4)

AfUE* Energuide 

(P4)

RHAP42N

67%

61%

68.5%

66%

RHAP54N 70.2% 66.9% 69.8% 71.8%

*AFUE (Annual Fuel Utilization Efficiency) is the 

recognized U.S. rating system for the total effi-

ciency of heating products.

Table 1

EffICIENCIES

REqUIREMENTS fOR COMMON-

WEALTH Of MASSACHUSETTS

These fireplaces are approved for installation in 

the US state of Massachusetts if the following 

additional requirements are met:
•  Install appliance in accordance with Massa-

chusetts Rules and Regulations 248 C.M.R. 

•  Installation and repair must be done by a 

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

•  The flexible gas-line connector used shall 

not exceed 36 inches (92 centimeters) in 

length.

•  The  individual  manual  shutoff  must  be  a 

T-handle type valve.

Massachusetts Horizontal Vent  

Requirements 

In the Commonwealth of Massachusetts, hori-

zontal terminations installed less than seven 

(7) feet above the finished grade must comply 

with the following additional requirements:

•  A  hard-wired  carbon  monoxide  detector 

with an alarm and battery backup must be 

installed  on  the  floor  level  where  the  gas 

fireplace is installed. The carbon monoxide 

detector must comply with NFPA 720, be 

ANSI/UL 2034 listed and be ISA certified.

•  A metal or plastic identification plate must 

be permanently mounted to the exterior of 

the building at a minimum height of eight (8) 

feet above grade and be directly in line with 

the horizontal termination. The sign must 

read, in print size no less than one-half (1/2) 

inch in size: GAS VENT DIRECTLY BELOW.  

KEEP CLEAR OF ALL OBSTRUCTIONS.

COLd CLIMATE INSULATION 

REqUIREMENTS

For cold climate installations:
•  Use noncombustible caulk to seal all joints 

around the appliance and wherever cold air 

could enter the room. 

•  Caulk all gas-line holes and other openings 

(or stuff with unfaced fiberglass insulation).  

•  Caulk firestops only where pipe penetrates 

an outside wall, attic, or other other uncon-

ditioned space.

•  If the floor is above ground level, insulate 

the outside chase cavity between the studs 

and under the floor beneath the appliance. 

•  If installing the fireplace on a cement slab, 

place  a  sheet  of  plywood  or  other  raised 

platform underneath to prevent cold transfer 

to the fireplace and into the room.

•  Drywall and tape all inside sur faces of sur-

rounding chase for maximum air tightness.

Содержание RHAP42N

Страница 1: ...damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D Y TOUCHER NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE...

Страница 2: ...ssory kits are available before installing fireplace ___________ Required for complete fireplace instal la tion Refer to the Rhapsody Linear Required and Optional Accessories manual 506019 84 for installation instructions for all required acces sories OPTIONAL ACCESSORIES Sold separately See Accessories section in fireplace Care and Operation Instructions Surround Kit ref manual 506019 84 Bezel Ki...

Страница 3: ...soning Do not attempt to alter or modify the construction of the appliance or its components Any modifi cation or alteration may void the warranty certification and Listings of this unit Thesefireplacesaredesignedassupple mentalheaters Therefore itisadvisable to have an alternate primary heat source when installed in a dwelling Theseappliancesmustnotbeconnected to a chimney or flue serving a separ...

Страница 4: ...is appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil ne peut être con verti à d autres gaz sauf si une trousse de conversion est utilisée CAUTION Ensure that the cross mem bers are not cut or weakened during installation The structural integrity of the ma...

Страница 5: ... Install reflector from Panel Backlighting Kit 27 Install side panels 27 Install back panel 27 optional Install light assemblies from Panel Backlighting Kit 27 Install Floor Kit 27 Install media required for certain style Floor Kits only 27 Install baffle 27 Install glass door 28 optional Install Bezel 29 12 Verify appliance operation 30 Lighting instructions 31 Air shutter adjustment 32 13 Finish...

Страница 6: ... 1 2 12 7 mm to unit 0 0 mm to spacers Sides 1 2 12 7 mm to unit 0 0 mm to spacers Top Spacers 0 0 mm Floor 0 0 mm Unit Bottom to Ceiling 65 1651 mm Vent Pipe Top 3 76 mm Sides 1 25 4 mm Bottom 1 25 4 mm SERVICE CLEARANCES Front 36 152 4 mm 3 76 mm above any horizontal inclined vent component See Framing the Fireplace Page 8 for clearance requirements to nailing flanges on unit sides and any adjac...

Страница 7: ...finish cleanface or surround and wall finish material thickness This is critical to ensure proper fireplace location especially if installing the optional Surround and Bezel See UNIT NAILING FLANGES on Page 9 LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODELS RHAP42N RHAP54N INSTALLATION INSTRUCTIONS LOCATION AND FRAMING Framing THE FIREPLACE 1 Assemble the top spacers Figure...

Страница 8: ...r dimension information only Fireplace must be adequately framed and supp A Required frame opening width 1 2 of A horizontal centerline of fireplace and vent framing opening B Required frame opening depth with 1 2 13mm thick wall finish material For other wall finish thicknesse 65 1651 E C D inches millimeters CEILING F A 1 2 of A Framing Dimensions Model Unit A B C D RHAP42N in 53 3 4 18 1 2 42 5...

Страница 9: ...on for cleanface finish and at 1 2 wall finish depth Cleanface Finish Nailing Flange Settings 1 Leave vertical position of nailing flanges at factory setting see Figure 8 DETAIL A 2 If wall finish material is thicker than 1 2 move nailing flanges to applicable horizontal setting Surround Bezel Nailing Flange Settings 1 Move vertical position of Top Nailing Flange UP and Bottom Nailing Flange DOWN ...

Страница 10: ...at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pres suretestingofthegassupplypipingsystem at test pressures equal to or less than 1 2 psi 3 5 kPa Orange Wire from DFC Wire Harness Pressure Regulator Tower Main Gas Inlet 3 8 NPT Green Wire from DFC Wire Harness Inlet IN Test Port Manif...

Страница 11: ...b 1 2 x 3 8 Flare Shut Off Valve 3 8 Flex Tubing 3 8 NPT x 3 8 Flare Fitting Gas Valve Flex Line Connector GAS REQUIREMENTS CONNECTION CONTINUED BURNER Orifice Sizes Sea Level to High Altitude These appliances are tested and approved for installation at elevations of 0 4500 feet 0 1372 meters above sea level using the standard burner orifice sizes marked with an asterisk in Table 5 For elevations ...

Страница 12: ...n it is NOT recom mended because soap residue can corrode pipes and fittings over time 1 Light the appliance refer to the lighting instructions in the Care and Operation Instructions or on the label attached to the door latch 2 Brush all joints and connections with the gas leak test solution If bubbles form or gas odor is detected turn the receiver or remote control to the OFF position Tighten or ...

Страница 13: ...engaged 3 Twist the section being attached CLOCK WISE running the dimples down and along the channels until seated at the ends of the channels The sections are properly seated when the arrow on one section aligns with the dimple on the other section The unitized design of Secure Vent compo nents will engage and seal both the inner and outer pipe without the need for sealant or screws If desired ho...

Страница 14: ...2 1 0 1 2 1 2 2 2 1 4 3 2 1 6 4 t n e V f o t h g i e H s n o i t c e S t n e V f o r e b m u N s e h c n i t f 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5 9 8 2 5 2 1 4 2 0 1 0 0 6 7 5 1 0 3 5 2 1 5 2 0 0 1 0 6 7 5 0 1 3 5 7 8 5 2 0 0 0 9 0 9 5 5 2 3 5 2 1 7 2 0 0 0 0 7 7 0 3 3 5 7 2 1 0 0 0 7 8 5 4 3 5 7 8 2 0 0 0 0 1 0 0 1 5 9 4 3 5 2 1 9 2 1 0 0 0 1 0 1 1 2 ...

Страница 15: ...ES in this manual Support vertical venting every 8 feet 2 4 m above appliance vent outlet VENT RUN SUPPORT REQUIREMENTS Supporting Vertical Vent Runs Note Proper venting support is very important NEVER use the fireplace to support the weight of the venting Support the vertical portion of the venting system every 8 feet 2 4 m above the fire place vent outlet see Figure 21 Use Support Straps cat no ...

Страница 16: ...ide the assembly up into the vent collar as shown in Figure 25 The vent restrictor is held in place by fric tion only The entire vent restrictor assembly must be up inside the vent collar with no portion showing inside the firebox Vent Restrictor Kit provided with fireplace 1 Vent Restrictor Base 2 Wings 4 Screws Figure 23 Flaps Figure 24 Setting 1 Vent Restrictor Base only is required for the fol...

Страница 17: ...ill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeovertheadaptorcol lar Ensure the flexible vent pipe completely engages the adaptor collar to a distance of 1 3 4 inches from the end and that it is free from damage or tears 5 Slide the gear clamp down and...

Страница 18: ... the fireplace collar and a 90 elbow For more details see Elbows on Page 14 typical VERTICAL Termination SYSTEMS Typical vertical termination systems are shown in Figures 28 29 and 30 Select the vent design that matches your requirements and make sure the vent run conforms to the rise to run ratios listed in Table 7 If the parameters of your vent run fall outside the parameters described herein co...

Страница 19: ...ombustible caulking silicone caulking is acceptable around entire cir cumference to ensure a water tight seal LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODELS RHAP42N RHAP54N INSTALLATION INSTRUCTIONS Figure 31 Clearance for Multiple Vertical Vent Terminations Min 12 305 mm 12 X Roof Pitch is X 12 2 FT MIN 2 FT MIN Lowest Discharge Opening H H MINIMUM HEIGHT FROM ROOF TO LO...

Страница 20: ...for more information See the VENTING INSTALLATION section on Pages 13 17 for additional details __________ u Vertical Firestop Spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal Firestop Spacer must be used anywhere vent pipe passes through a combustible wall For further details see Firestop Spacer Requirements on Page 13 Install the provided Vent Restr...

Страница 21: ...ustible projection less than or equal to 2 1 2 64 mm See Figure 38 For projections greater than 2 1 2 64 mm see Figure 38 For additional vent location restrictions see Page 22 NOTICE Horizontal terminations have been designed to perform in a wide range of weather condi tions Our terminations meet or exceed industry standards When selecting the locations of your horizontal terminations do not place...

Страница 22: ... e e n i l r e t n e c f o e d i s h c a e o t e c n a r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e l t u o t n e v r o t a l u g e r e c i v r e...

Страница 23: ...ed with the termination to the vent section or telescoping vent section or elbow in the same manner as the other vent components see Attaching Secure Vent Components on Page 13 Note If blown insulation is to be used the Through Wall Shield Kit H5816 MUST be installed 3 Install firestop spacer at exterior wall See Figure 40 Install the firestop spacer over the opening at the exterior side of the fr...

Страница 24: ...rson WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier Due to high temperatures keep children and furniture away Keep burner and control compartment clean See insta...

Страница 25: ...vided Connect the wires as shown in Figure 42 Reinstall the junction box by compressing the sides then place the small flange of the Junction box in the small slot Place the larger flange into the larger slot and release Replace the cover on the original junction box location 1 2 Remove the electrical inlet cover plate from the back of the unit by removing the plate s securing screws The junction ...

Страница 26: ...azard Can cause severe injury or death The receiver causes ignition of the appli ance The appliance can turn on suddenly Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system CAUTION Propertydamagehazard Excessive heat can cause property damage The appliance can stay lit for many hours Turn off the appliance if it is not going to be a...

Страница 27: ...anel Backlighting Kit OPTIONAL See Rhapsody Required and Optional Acces sories manual 506019 84 3 Install Panel Kit REQUIRED SOLD SEPARATELY Install the two side panels first then the back panel See Rhapsody Required and Optional Acces sories manual 506019 84 4 Install light assemblies from Panel Backlighting Kit OPTIONAL See Rhapsody Required and Optional Acces sories manual 506019 84 5 Install F...

Страница 28: ...nly when fireplace is OFF and COLD Do not attempt to touch the front enclo sure glass with your hands while the fireplace is in use The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched Even after the gas is turned off fireplace surfaces remain extremely hot Do NOT abuse glass door by striking or slamming shut INSTALLATION REMOVAL of GLAS...

Страница 29: ...ard the door Figure 51 2 Gently push the lower edge of the bezel to attach the bezel lower flange to the lower edge of the glass door frame Reverse these steps to remove the bezel Figure 51 Figure 50 Bezel Upper Flange Bezel Lower Flange CROSS SECTION Glass Door Frame INSTALL MODESTY PANEL NOTE Modesty panel will not be used if surround and bezel will be installed To install the modesty panel inse...

Страница 30: ... attached to one of the lower door brackets When first lighting the appliance it will take a few minutes for the gas line to purge itself of air Once purging is complete the pilot and burner will light and operate as indicated in the instruction manual Appliance Checkout To light the burner slide the wall switch to the ON position or use the remote control with the wall switch in the REMOTE positi...

Страница 31: ... service technician Do not use tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 3 Turn off all electric power to the appliance if service is to be performed...

Страница 32: ...resent first ensure that the flames are not impinging on any of the panels If the panels are properly posi tioned and a sooting condition still exists increase the air shutter opening The more offsets in the vent system the larger the air shutter opening will need to be An appliance operated with the air shutter opened too far may have flames that appear blue and transparent Propane models may exh...

Страница 33: ...TTOM Nailing Flanges are attached to fireplace in the correct VERTI CAL position for Surround Bezel Finish and the correct HORIZONTAL position for the wall finish material thickness see Page 9 2 LEFT RIGHT SIDE NAILING FLANGES REMOVE the LEFT and RIGHT SIDE Nailing Flanges see Figure 56 and discard using appropriate disposal methods 3 LEFT RIGHT FILLER ANGLE BRACKETS REMOVE the two Filler Angle Br...

Страница 34: ...nit Lip on Top Nailing Flange Bottom edge of Fiber Board abuts lip Combustible Wall Finish Material Top Non Combustible Fiber Board provided with fireplace Wall Stud Insulation and combustible material NOT ALLOWED in clearance zones around vent components Header Header Cleanface Finish Surround Bezel Finish Position of Top and Bottom Nailing Flanges depends on type and thickness of wall finish See...

Страница 35: ...t parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces degraisseoud huile Collezl étiquettesurleboîtier de la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Si vous n...

Страница 36: ...top Spacer Vertical rigid 1 1 1 spacing 10 pk 96K92 SV4 5SP Support Plate Vent Sections Rigid Listed Secure Vent Components Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square 1 pk ref manual 750109M 17M53 SV4 5HGS 12 Termination Guard Horizontal 12 pk ref manual 750109M 87L02 SV4 5HGS Termination Guard for Horizontal Termination Deluxe 1 pk ref manual 750055M H5820 SV4 5HTSK Terminatio...

Страница 37: ...lex with36inch 914 mm compressedflex 77L91 SFKIT48S Horiz Termination forflex with48inch 1219 mm compressedflex 56L74 SFVT30 Vertical Termination for flex flat to 6 12 with flex adaptor section of rigid vent roof support collar assembly roof flashing and storm collar ref manual 750052M 56L75 SFVT45 Vertical Termination for flex 6 12 to 12 12 with flex adaptor section of rigid vent roof support col...

Страница 38: ...ur appli ance will provide many years of enjoyment If you experience any problem first refer to the troubleshooting guide in this manual If the problem persists or you have any questions about your fireplace system contact your Lennox Hearth Products dealer or distributor Order parts through your Lennox Hearth Products dealer or distributor Parts will be shipped at prevailing prices at time of ord...

Страница 39: ...ire Harness H8330 1 14 Baffle Top Linear H8787 H8583 1 15 Door Assembly Fireplace Glass Enclosure H8799 H8431 1 A 1 Ground Wire H7278 1 A 2 DFC Ignition Board H7272 1 A 3 Gas Valve NG H7270 1 Gas Valve Propane H7271 1 A 4 Pilot Assembly NG H7268 1 Pilot Assembly Propane H7269 1 A 5 Fan Control Module H7274 1 A 6 Blower Assembly FBK 100 80L84 1 A 7 SIM Flame module only H8439 1 A 8 Light Bulb 25W H...

Страница 40: ...vious page LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODELS RHAP42N RHAP54N INSTALLATION INSTRUCTIONS 25 1 67 5 D B R E V 00 4 Power 120V Out Fan Aux Out 9 Power 120V Out Fan Aux Out A 1 Power 120V Out Fan Aux Out A 4 Power 120V Out Fan Aux Out A 2 Power 120V Out Fan Aux Out A 3 Power 120V Out Fan Aux Out A 5 A 6 A 10 A 9 A 7 SimFlame A 8 25 1675 DB REV 004 25 1675 DB REV 0...

Страница 41: ...41 NOTES LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODELS RHAP42N RHAP54N INSTALLATION INSTRUCTIONS ...

Страница 42: ...cifications and prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industries Inc and are used with permission LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODELS RHAP...

Отзывы: