NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
30
LENNOX HEARTH PRODUCTS • RHAPSODY™ LINEAR DIRECT-VENT GAS FIREPLACES (MODELS RHAP42N & RHAP54N) • INSTALLATION INSTRUCTIONS
With the gas-line installed, run the initial
system checkout before closing up the front
of the unit.
Follow the pilot lighting instructions provided
in
on the next page
.
Note: Lighting instructions (and rating plate)
are also provided on a tag attached to one
of the lower door brackets.
When first lighting the appliance, it will take
a few minutes for the gas-line to purge itself
of air. Once purging is complete, the pilot and
burner will light and operate as indicated in the
instruction manual.
Appliance Checkout
To light the burner, slide the wall switch to the
ON position (or use the remote control with the
wall switch in the REMOTE position).
Ensure the igniter lights the pilot. The pilot
flame should engulf the flame sensor rod, as
shown in
Figure 52
.
Pilot
Hood
Sensor
Ignitor
Figure 52
Igniter
flame Rod
(sensor)
VERIfyINg APPLIANCE
OPERATION