Lennox Hearth Products RAVENNA RDV33 Скачать руководство пользователя страница 9

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Insert Dimensions

Minimum Fireplace Cavity

31-1/4”

(794mm)

13-3/4”

(349mm)

15-3/4"

(400mm)

19-3/4

(502mm)

15-3/4"

(400mm)

19-1/2"

(495mm)

Top View

Side View

Insert Dimensions

Width of insert behind Surround Panels

31-1/4" (794mm)

Rear height

19-3/4" (502mm)

Insert depth into fireplace

16" (406mm)

Flue collar diameter (OD) 

2-15/16"

2-15/16" (75mm)

A

B

C

D

       CAUTIONS 

 

Trim panels or surrounds must not seal ventila-

tion openings in the existing fireplace that the 

appliance is installed in.

 

The fireplace in which this gas insert is to be 

installed must be thoroughly cleaned if it has 

been used to burn wood or synthetic logs. Have 

the chimney and all inside surfaces of the fire-

place brushed and vacuumed so that no soot, 

embers, or loose combustion deposits can be 

drawn into the heat circulation blower and blown 

into the living area. 

 

If any portion of the chimney system shows signs 

of structural or mechanical weaknesses, such 

as:  cracks,  leaky  joints,  corroded  or  warped 

surfaces,  the  faulty  portion  must  be  repaired 

or replaced prior to installing this appliance.

 

The factory built firebox must accept the insert 

without modification other than removing bolted 

or  screwed  together  pieces  such  as  baffles  / 

smoke shelf / deflectors, ash lips, glass door, 

screen or door tracks, log grates, refractory or 

masonry  lining  and  damper  assemblies.  Any 

fireplace component, which is removed, must be 

retained so they can be reinstalled to restore the 

fireplace to its original operating condition. The 

removal of any part must not alter the integrity 

of the outer shell of the pre-engineered fireplace 

cabinet in any way.  Any parts removed must be 

replaceable.  If any components are removed 

from  (or  altered)  from  the  existing  fireplace, 

a Warning Label (see 

Page 6)

 must be affixed 

inside the fireplace firebox, so that it shall be 

visible upon removal of the fireplace insert.  

Note: 

RTV high temperature silicone is an approved 

adhesive to affix the label. 

Figure 1

Figure 2

Figure 3

Minimum Fireplace Opening

A

31-1/4" (794mm) Front Opening

B

19-1/2” (495mm) Height

C

19” (483mm) Rear Width

D

16” (406mm) Fireplace Depth

* Top air duct will need to be removed for short ZC applications. 

Replace tap tights when removed.

Содержание RAVENNA RDV33

Страница 1: ...les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service...

Страница 2: ...bles 10 Insert Leveling 10 Installation 11 13 Venting Installation 11 Zero Clearance Fireplace Installation 12 Brick Panel and Log Set Installation 12 Surround Panels Installation 13 Face Installation...

Страница 3: ...ller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...onnected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only f...

Страница 5: ...red quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperf...

Страница 6: ...hall not be altered by the installation of the insert i e DO NOT BLOCK louvers or cooling air inlet or outlet ports circulating air chambers in a steel fireplace liner or metal heat circulator See Pag...

Страница 7: ...recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified by OMNI Test Laboratories to AN...

Страница 8: ...ng List 1 Insert Body with Burner Cassette 1 Set of Refractory Brick Panels 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restrai...

Страница 9: ...rfaces the faulty portion must be repaired or replaced prior to installing this appliance The factory built firebox must accept the insert withoutmodificationotherthanremovingbolted or screwed togethe...

Страница 10: ...bove the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration The letters below E through J correspond to Figure 5 showing minimum clearancesrequ...

Страница 11: ...place Figure 6b WARNING Direct VentFireplaceInsertVentRequirements Useliner listed to UL181 Factory made Air Ducts And Air Connec tors orUL1777 ChimneyLiners fortheAIRINTAKE Use liner listed to UL1777...

Страница 12: ...ure des parois ou au fond de la chambre de combustion Cetorificedoit treobtur aumoyend isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supp...

Страница 13: ...rt two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the sur...

Страница 14: ...e com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels LP and Natural Gas Supplies Your gas appliance is equipped from the factory for use with natural gas...

Страница 15: ...LLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 15a Figure 15b SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 16: ...e le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces...

Страница 17: ...plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by...

Страница 18: ...our service technician or gas supplier 10 After pilot is lit turn gas control knob counterclockwise to ON Knob can only be turned to ON if the knob has popped out 11 To turn burner on turn ON OFF rock...

Страница 19: ...gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than...

Страница 20: ...es to the appliance for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions in...

Страница 21: ...ER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at...

Страница 22: ...lass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Glass Door Only...

Страница 23: ...weennaturalgasandLPcanbeaccomplished by installing a conversion kit valve regulator and burner orifice Only a qualified service technician should perform the conversion Conversion Kit Please see instr...

Страница 24: ...wire Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap b...

Страница 25: ...Glowing Embers rockwool H3130 Firebox Door w Glass H5989 Hardware Package H5839 Log Set Support H5913 Hinge Right Double Door W Screen all Faces H5914 Hinge Left Double Door W Screen all Faces H5980 K...

Страница 26: ...IC Black Nickel 75330 NAPA Black 75298 TUSCAN Black 75332 NAPA Gold 75300 TUSCAN Gold 75331 NAPA Brushed Nickel 75299 TUSCAN Brushed Nickel 75333 NAPA Black Nickel 75301 TUSCAN Black Nickel Controls H...

Страница 27: ...plete face 37 5 8 W x 23 3 4 H 75093 PILCST GLASS Glass Door Box 1 of 3 ref form 775258M 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 7509...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL RDV33 40 AND SDVI33 40 2011 2012 2013 2014...

Страница 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LIGHTING LABEL RDV33 40 AND SDVI33 40...

Страница 30: ...cement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of or...