Lennox Hearth Products RAVENNA RDV33 Скачать руководство пользователя страница 18

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

       WARNINGS

 

Improper installation, adjustment, alteration, 

service  or  maintenance  can  cause  injury  or 

property damage. For assistance or additional 

information, consult a qualified installer, service 

agency or your gas supplier.

 

Operation of this appliance when not connected 

to a properly installed and maintained venting 

system  can  result  in  carbon  monoxide  (CO) 

poisoning and possible death.

 

Carbon  monoxide  poisoning  –  early  signs  of 

carbon  monoxide  poisoning  resemble  the  flu 

with headaches, dizziness, or nausea.  If you 

have these signs, get fresh air at once!  Have 

the  heater  inspected  by  a  qualified  service 

technician.  Some people are more affected by 

carbon monoxide than others.  These include 

pregnant  women,  people  with  heart  or  lung 

disease or anemia, those under the influence 

of alcohol and those at high altitudes.

9.   Push in control knob all the way and hold in. Immediately light 

the pilot by triggering the piezo igniter (pushing the button) 
until pilot lights. Continue to hold the control knob in for about 
1­1/2 minutes after the pilot is lit. Release knob and it will pop 
back out. Pilot should remain lit. If it goes out, repeat steps 
5­9. 

•  If knob does not pop up when released, stop and immedi­

ately call your service technician or gas supplier.

•  If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your service technician or 
gas supplier.

10. After pilot is lit, turn gas control knob counterclockwise                 

.2

                 to "ON." Knob can only be turned to "ON" if the knob 

has popped out.

11. To  turn  burner  on,  turn  "ON/OFF"  rocker  switch  to  "ON"  or 

set the thermostat to the desired temperature above room 
temperature.

12. Adjust the flame height (and heat output) by turning the flame 

height knob clockwise               for full flame and counterclock­
wise               for reduced flame.

13. Turn on the electric power to the appliance and set the blower 

to the desired air flow after it turns on when the appliance 
reaches operating temperature.

TO TURN OFF GAS TO APPLIANCE

1.   Turn  off  the  "ON/OFF"  rocker  switch  and/or  thermostat  (if 

installed) to its lowest setting.

2.   Turn  off  electric  power  to  the  appliance  if  service  is  to  be 

performed.

3.   Access the control compartment. Push in gas control knob 

slightly and turn clockwise           to "OFF."  Do not force.

SHUTDOWN PROCEDURE

To turn off the burner, turn the rocker switch to "OFF" or adjust 

the thermostat (if installed) to a setting below room temperature. 

The pilot will remain lit for future burner ignition. For complete 

shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.

PILOT ASSEMBLY

Thermopile

Veilleuse à gaz Igniter (electrode)

Allumeur

Thermocouple

Gas Pilot Hood

Robertshaw Millivolt Gas Valve

TP/TH

TH

TP

Gas Control Knob 

(Pilot / On / Off)

O

FF

O

N

Piezo Igniter

Allumeur

ON/OFF Switch

Interrupteur

Flame Height Control 

Knob (HI/LO)

Figure 16

IMPORTANT NOTE: When opening the lower door on the face 

while the insert is burning, pull at the far left or far right 

vent openings, because the door is hot during operation.

Содержание RAVENNA RDV33

Страница 1: ...les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service...

Страница 2: ...bles 10 Insert Leveling 10 Installation 11 13 Venting Installation 11 Zero Clearance Fireplace Installation 12 Brick Panel and Log Set Installation 12 Surround Panels Installation 13 Face Installation...

Страница 3: ...ller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...onnected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only f...

Страница 5: ...red quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperf...

Страница 6: ...hall not be altered by the installation of the insert i e DO NOT BLOCK louvers or cooling air inlet or outlet ports circulating air chambers in a steel fireplace liner or metal heat circulator See Pag...

Страница 7: ...recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified by OMNI Test Laboratories to AN...

Страница 8: ...ng List 1 Insert Body with Burner Cassette 1 Set of Refractory Brick Panels 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restrai...

Страница 9: ...rfaces the faulty portion must be repaired or replaced prior to installing this appliance The factory built firebox must accept the insert withoutmodificationotherthanremovingbolted or screwed togethe...

Страница 10: ...bove the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration The letters below E through J correspond to Figure 5 showing minimum clearancesrequ...

Страница 11: ...place Figure 6b WARNING Direct VentFireplaceInsertVentRequirements Useliner listed to UL181 Factory made Air Ducts And Air Connec tors orUL1777 ChimneyLiners fortheAIRINTAKE Use liner listed to UL1777...

Страница 12: ...ure des parois ou au fond de la chambre de combustion Cetorificedoit treobtur aumoyend isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supp...

Страница 13: ...rt two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the sur...

Страница 14: ...e com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels LP and Natural Gas Supplies Your gas appliance is equipped from the factory for use with natural gas...

Страница 15: ...LLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 15a Figure 15b SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 16: ...e le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces...

Страница 17: ...plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by...

Страница 18: ...our service technician or gas supplier 10 After pilot is lit turn gas control knob counterclockwise to ON Knob can only be turned to ON if the knob has popped out 11 To turn burner on turn ON OFF rock...

Страница 19: ...gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than...

Страница 20: ...es to the appliance for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions in...

Страница 21: ...ER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at...

Страница 22: ...lass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Glass Door Only...

Страница 23: ...weennaturalgasandLPcanbeaccomplished by installing a conversion kit valve regulator and burner orifice Only a qualified service technician should perform the conversion Conversion Kit Please see instr...

Страница 24: ...wire Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap b...

Страница 25: ...Glowing Embers rockwool H3130 Firebox Door w Glass H5989 Hardware Package H5839 Log Set Support H5913 Hinge Right Double Door W Screen all Faces H5914 Hinge Left Double Door W Screen all Faces H5980 K...

Страница 26: ...IC Black Nickel 75330 NAPA Black 75298 TUSCAN Black 75332 NAPA Gold 75300 TUSCAN Gold 75331 NAPA Brushed Nickel 75299 TUSCAN Brushed Nickel 75333 NAPA Black Nickel 75301 TUSCAN Black Nickel Controls H...

Страница 27: ...plete face 37 5 8 W x 23 3 4 H 75093 PILCST GLASS Glass Door Box 1 of 3 ref form 775258M 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 7509...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL RDV33 40 AND SDVI33 40 2011 2012 2013 2014...

Страница 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LIGHTING LABEL RDV33 40 AND SDVI33 40...

Страница 30: ...cement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of or...

Отзывы: