Lennox Hearth Products RAVENNA RDV33 Скачать руководство пользователя страница 10

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible 
or equivalent, with a k factor of .84.

Insert Leveling

At each front and rear corner of the insert is an adjustable leg provided 
to level the insert should the hearth of the fireplace be uneven. To adjust 
the legs, loosen the two 5/32" allen head screws, move the leg to the 
desired height and then tighten the screws. Repeat these steps for each 
adjusting leg.

RDV40

SDVI40

G

14”(356mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

IMPORTANT: If unit is converted to an RDV33 / SDVI33  from 

an RDV40 / SDVI40, the clearances to combustibles can be 

reduced as shown on this page. 
WARNING: If this unit is ever converted back to an RDV40 / 

SDVI40, ensure that the clearances are correct for this model.

RDV33

SDVI33

G

13”(330mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

E

H

F

G

J

CL

MANTEL

TRIM

Mantel

Trim

Hearth / Floor Protection

Minimum clearances include any projections such as shelves, window 
sills, mantels, spacers/standoffs or surfaces to combustible construction 
etc. above the appliance. Paint or lacquer used to finish the mantel 
must be heat resistant in order to avoid discoloration.

The letters below, E through J, correspond to 

Figure 5

 showing minimum 

clearances required from the appliance to combustibles and the minimum 
projection of the hearth extension.

E =  From Top Facing or Mantel to Bottom of Insert ­ RDV40/SDVI40 = 

35­1/2”(902mm) and RDV33/SDVI33 = 31­1/2”(800mm)

F =  25­1/2" From Center of Glass Door to Side Facing or Wall ­ RDV40/ 

SDVI40 = 25.5”(648mm) and RDV33/SDVI33 = 25.5” (648mm)

J = 10.5” (267mm) Mantel to Bottom of Insert ­ RDV40/SDVI40 = 

43”(1092mm) and RDV33/SDVI33 = 39”(991mm)

Hearth Protection

G =  Minimum Hearth Protection from Front of Insert*
H = Vertical Distance from Insert Bottom to Combustible Material.

Clearances to Combustibles

Minimum Clearances to Combustibles

Figure 4A

Figure 5

 - Clearances

RDV40

Facing and 

Mantel - Side 

View

Facing and Mantel Clearances 

Please note that the RDV33/SDVI33 mantel clearances are 4" less than 

the RDV40/SDVI40 mantel clearances as shown in 

Figures 4A

 (RDV40) 

and 

4B

 (RDV33/SDVI33).

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

35-1/2”

902mm

37-1/2”

953mm

40-1/2”

1029mm

43-1/2”

1105mm

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

31-1/2”

800mm

33-1/2”

851mm

36-1/2”

927mm

39-1/2”

1003mm

RDV33/SDVI33

Facing and 

Mantel - Side 

View

Figure 4B

Содержание RAVENNA RDV33

Страница 1: ...les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service...

Страница 2: ...bles 10 Insert Leveling 10 Installation 11 13 Venting Installation 11 Zero Clearance Fireplace Installation 12 Brick Panel and Log Set Installation 12 Surround Panels Installation 13 Face Installation...

Страница 3: ...ller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...onnected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only f...

Страница 5: ...red quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperf...

Страница 6: ...hall not be altered by the installation of the insert i e DO NOT BLOCK louvers or cooling air inlet or outlet ports circulating air chambers in a steel fireplace liner or metal heat circulator See Pag...

Страница 7: ...recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified by OMNI Test Laboratories to AN...

Страница 8: ...ng List 1 Insert Body with Burner Cassette 1 Set of Refractory Brick Panels 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restrai...

Страница 9: ...rfaces the faulty portion must be repaired or replaced prior to installing this appliance The factory built firebox must accept the insert withoutmodificationotherthanremovingbolted or screwed togethe...

Страница 10: ...bove the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration The letters below E through J correspond to Figure 5 showing minimum clearancesrequ...

Страница 11: ...place Figure 6b WARNING Direct VentFireplaceInsertVentRequirements Useliner listed to UL181 Factory made Air Ducts And Air Connec tors orUL1777 ChimneyLiners fortheAIRINTAKE Use liner listed to UL1777...

Страница 12: ...ure des parois ou au fond de la chambre de combustion Cetorificedoit treobtur aumoyend isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supp...

Страница 13: ...rt two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the sur...

Страница 14: ...e com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels LP and Natural Gas Supplies Your gas appliance is equipped from the factory for use with natural gas...

Страница 15: ...LLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 15a Figure 15b SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 16: ...e le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces...

Страница 17: ...plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by...

Страница 18: ...our service technician or gas supplier 10 After pilot is lit turn gas control knob counterclockwise to ON Knob can only be turned to ON if the knob has popped out 11 To turn burner on turn ON OFF rock...

Страница 19: ...gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than...

Страница 20: ...es to the appliance for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions in...

Страница 21: ...ER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at...

Страница 22: ...lass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Glass Door Only...

Страница 23: ...weennaturalgasandLPcanbeaccomplished by installing a conversion kit valve regulator and burner orifice Only a qualified service technician should perform the conversion Conversion Kit Please see instr...

Страница 24: ...wire Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap b...

Страница 25: ...Glowing Embers rockwool H3130 Firebox Door w Glass H5989 Hardware Package H5839 Log Set Support H5913 Hinge Right Double Door W Screen all Faces H5914 Hinge Left Double Door W Screen all Faces H5980 K...

Страница 26: ...IC Black Nickel 75330 NAPA Black 75298 TUSCAN Black 75332 NAPA Gold 75300 TUSCAN Gold 75331 NAPA Brushed Nickel 75299 TUSCAN Brushed Nickel 75333 NAPA Black Nickel 75301 TUSCAN Black Nickel Controls H...

Страница 27: ...plete face 37 5 8 W x 23 3 4 H 75093 PILCST GLASS Glass Door Box 1 of 3 ref form 775258M 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 7509...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL RDV33 40 AND SDVI33 40 2011 2012 2013 2014...

Страница 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LIGHTING LABEL RDV33 40 AND SDVI33 40...

Страница 30: ...cement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of or...

Отзывы: