Note:

  The minimum vertical rise (exhaust vent) is 10 feet (3.1 M) and the 

maximum vertical rise is 35 feet (10.7 M). These dimensions are measured 

from the starting collars of the unit to the end of the vent pipe.
The fireplace and fireplace chimney must be clean and in good working 

order and constructed of non­combustible materials. Inspect chimney 

cleanouts for proper fit and seal.
* Other approved vent components include; Standard Simpson Dura-

vent Co-linear Chimney Liner Kit, Direct-Vent Termination #991, Liner 

Termination Kit (includes termination connector and flashing) #923GK 

and 3" x 35' Alum Flex #2280

Venting Installation

Your appliance must be vented to the outside in accordance with the 

current edition of the National Fuel Gas Code ANSI­Z223.1 (In Canada, 

the current CAN/CSA  B149.1 installation code).  The insert must not be 

connected to a chimney flue serving a separate solid fuel burning appliance.
This gas insert requires a 3” diameter listed flex liner. The vent should 

terminate with a listed direct­vent termination cap. The chimney should be 

sealed around the cap to prevent air and rain from entering the chimney. 

Adhere to the vent manufacturer's instructions for installation and vent 

termination. These appliances are approved for use with the following 

vent kits.

Vertical Cap

Termination 

Connector

Exhaust

Intake

Combustion Air Intake

The existing fireplace chimneys 

may  take  various  contours 

which  the  flexible  liners  will 

accommodate. However, keep 

the flexible liner as STRAIGHT 

as possible, avoid unnecessary 

bending.

Liner Requirements:

Vertical Height Min. = 10 ft. (3.1 M)

Vertical height Max. = 35 ft. (10.7 M)

Note: Measured from flue collar on 

unit to the end of the vent pipe or liner

Use 3" (76 mm) diameter listed gas 

vent liner (UL1777 ONLY) for the 

EXHAUST

Use 3" (76 mm) diameter listed 

liner (UL 181 or UL1777) for the 

AIR INTAKE.

The flexible vent pipe 

must NOT be allowed to 

sag behind  insert or in 

fireplace flue.

Make sure that both liners will pass through existing damper area. Remove 

or lock damper to allow the passage of the flexible liners. If the damper 

will not allow the passage of both liners, DO NOT PROCEED FURTHER.  

(If fireplace is masonry) Consult a local mason for removal of the damper 

without risk of structural damage or leakage (if the fireplace is factory 

built) The appliance may NOT be installed into the fireplace.

Figure 6b

        

WARNING

Direct-Vent Fireplace Insert Vent Requirements - Use liner 

listed to UL181 (Factory-made Air Ducts And Air Connec-

tors) or UL1777 (Chimney Liners) for the AIR INTAKE.  Use 

liner listed to UL1777 ONLY for the EXHAUST.
Do not substitute the heat-rated flex liner (UL1777) for the 

exhaust with any other type liner or a fire may result caus-

ing property damage, personal injury or loss of life.

The standard cap in Termination Kit TKDVI, and in 
Vent Kit DV3FK35

 

is a high wind cap

Vent Kits 

Cat. No.

Model

Description

H0909

FKDVI

Flex Liner Kit, DVI 3” X 35’ (requires 2, one for 
exhaust and one for intake)

TKDVI

TKDVI

Termination Kit, DVI (termination cap and flashing)

DV3FK35 DV3FK35 Flex Liner and Termination Kit, 3" X 35' (includes 2 

flex liners, termination and gear clamps)

INSTALLATION

Air Inlet Liner (for combustion air) When 

terminating the air inlet liner at this point, a 

positive flue connection is required (to ensure 

combustion air is drawn down the chimney 

only).

Exhaust 3" (75mm) UL 

1777. A full length liner 

is required from the 

exhaust outlet on appli-

ance to center collar of 

termination cap.

Positive Flue Con-

nection (sealing 

fireplace throat 

using a noncombus-

tible seal-off plate 

or insulation).

The outside air inlet does not 

require a full reline (if intake 

liner is terminated in chimney 

and a positive flue connection 

is achieved as specified).

Ai

r I

nl

et

Ex

ha

us

t

Ai

r I

nl

et

Existing Fireplace Flue

(chimney)

Masonry and Factory Built Fireplaces

Figure 6a - Terminating Air Inlet in Chimney 

NOTE: Terminating the air intake liner as shown here may not be al-

lowed by some local codes.  Check with the authority having jurisdiction 

for your area.

Vertical Venting

The vent pipes must be connected to the proper collars on the unit and 

the exhaust vent pipe must be connected to the termination cap or the 

unit will not operate. 
The combustion air intake pipe can be connected to the termination cap 

(see 

Figure 6b

) or it can terminate inside the chimney (see 

Figure 6a

).  

If combustion air intake pipe is terminated inside the chimney and not 

connected to the actual termination cap the bottom opening of the chim­

ney (chimney throat) must be sealed around the vent pipes.  Use a non 

combustible seal­off plate (i.e. 22 gage sheet steel) or unfaced fiberglass 

insulation (8 lb per square foot density minimum) to seal around the vent 

pipes.  Whichever “seal off” method is used must effectively seal the area 

to prevent room air passage to the chimney of the fireplace.  The insulation 

may give off an odor during the first hour of operation.

Содержание RAVENNA RDV33

Страница 1: ...les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service...

Страница 2: ...bles 10 Insert Leveling 10 Installation 11 13 Venting Installation 11 Zero Clearance Fireplace Installation 12 Brick Panel and Log Set Installation 12 Surround Panels Installation 13 Face Installation...

Страница 3: ...ller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...onnected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only f...

Страница 5: ...red quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperf...

Страница 6: ...hall not be altered by the installation of the insert i e DO NOT BLOCK louvers or cooling air inlet or outlet ports circulating air chambers in a steel fireplace liner or metal heat circulator See Pag...

Страница 7: ...recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified by OMNI Test Laboratories to AN...

Страница 8: ...ng List 1 Insert Body with Burner Cassette 1 Set of Refractory Brick Panels 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restrai...

Страница 9: ...rfaces the faulty portion must be repaired or replaced prior to installing this appliance The factory built firebox must accept the insert withoutmodificationotherthanremovingbolted or screwed togethe...

Страница 10: ...bove the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration The letters below E through J correspond to Figure 5 showing minimum clearancesrequ...

Страница 11: ...place Figure 6b WARNING Direct VentFireplaceInsertVentRequirements Useliner listed to UL181 Factory made Air Ducts And Air Connec tors orUL1777 ChimneyLiners fortheAIRINTAKE Use liner listed to UL1777...

Страница 12: ...ure des parois ou au fond de la chambre de combustion Cetorificedoit treobtur aumoyend isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supp...

Страница 13: ...rt two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the sur...

Страница 14: ...e com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels LP and Natural Gas Supplies Your gas appliance is equipped from the factory for use with natural gas...

Страница 15: ...LLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 15a Figure 15b SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 16: ...e le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces...

Страница 17: ...plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by...

Страница 18: ...our service technician or gas supplier 10 After pilot is lit turn gas control knob counterclockwise to ON Knob can only be turned to ON if the knob has popped out 11 To turn burner on turn ON OFF rock...

Страница 19: ...gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than...

Страница 20: ...es to the appliance for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions in...

Страница 21: ...ER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at...

Страница 22: ...lass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Glass Door Only...

Страница 23: ...weennaturalgasandLPcanbeaccomplished by installing a conversion kit valve regulator and burner orifice Only a qualified service technician should perform the conversion Conversion Kit Please see instr...

Страница 24: ...wire Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap b...

Страница 25: ...Glowing Embers rockwool H3130 Firebox Door w Glass H5989 Hardware Package H5839 Log Set Support H5913 Hinge Right Double Door W Screen all Faces H5914 Hinge Left Double Door W Screen all Faces H5980 K...

Страница 26: ...IC Black Nickel 75330 NAPA Black 75298 TUSCAN Black 75332 NAPA Gold 75300 TUSCAN Gold 75331 NAPA Brushed Nickel 75299 TUSCAN Brushed Nickel 75333 NAPA Black Nickel 75301 TUSCAN Black Nickel Controls H...

Страница 27: ...plete face 37 5 8 W x 23 3 4 H 75093 PILCST GLASS Glass Door Box 1 of 3 ref form 775258M 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 7509...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL RDV33 40 AND SDVI33 40 2011 2012 2013 2014...

Страница 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LIGHTING LABEL RDV33 40 AND SDVI33 40...

Страница 30: ...cement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of or...

Отзывы: