NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Remove Cardboard

Figure 9

Step 6: REMOVE CARDBOARD 

-  Remove the 

cardboard packaging material from beneath 
the relief door and discard (see Figure 9).

Wiring - Optional Forced Air Blower Kit:

BK-CI (see Figure 11 for wiring diagram) -  (An 
optional fi eld-provided outletbox/J-Box may 
also be used). Install the blower kit according 
to the installation instructions provided with 
the kit.

Figure 11

Blower
Mounting 
Bracket

Black

Black

White

White

Fan Disc

  Rheostat

Blower
Assembly 
(Shown 
Rotated 90 
Degrees CCW)

Black

Power Cord

IMPORTANT: Ground supply wire must be 
connected to the green wire attached to 
the green ground screw.  Failure to do so 
will result in a potential safety hazard. The 
appliance must be electrically grounded 
in accordance with local codes or, in the 
absence of local codes, the National Elec-
trical Code, ANSI/NFPA 70 - latest edition. 
In Canada, the current CSA C22-1 Canadian 
Electrical - latest edition. 

WARNING: THE POWER CORD MUST BE 
PLUGGED DIRECTLY INTO A PROPERLY 
GROUNDED THREE-PRONG 120 VOLT, 60 HZ 
WALL RECEPTACLE. Do not cut or remove 
the grounding prong from this plug.  Do 
not route power cord under or in front of 
appliance.

Step 7: INSTALL LP CONVERSION KIT (IF 
NECESSARY) AND OPTIONAL ACCESSORIES 

Install the LP conversion kit and optional 

accessories per instructions provided with 
the kits (do not install an optional fi rescreen 
or brick liner kit at this point).

A. Optional accessories include a wall ther-

mostat, blower kit, brick liner kit, warming 
shelves and a standard or deluxe remote 
control kits. 

B. If a wall-mounted thermostat is selected, 

mount it in a convenient location on a wall 
near the stove. If the warming shelves are 
being installed, see Homeowners Manual for 
installation instructions.

C. Wire the thermostat within the millivolt control 

circuit using a maximum of 25 feet of 18 gage, 
2 conductor wire. Caution: Do not connect the 
optional wall thermostat, gas control valve or 
control wiring system of the unit to a 120 volt 
power supply (residential line voltage) 

The gas valve is set in place and pre-wired at the 
factory on both models (see Figure 11).

       SIT Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

 

Type AWM105

°

C – 18 GA. wire.

Thermopile

TH

TP

TH

TP

* ON/OFF SWITCH, OPTIONAL 
   THERMOSTAT

    OR REMOTE 

* SWITCH

CONTROL RECEIVER

Figure 10

Blower Wiring Diagram

RELIEF DOOR

The lower access 
door hinges open 
to access  Valve 
Controls

Lower Access

Door

Figure 12

Step 8: INSTALL LOWER ACCESS DOOR 

.

Install the lower access door by inserting the 

tabs on the door sides into the corresponding 
holes on the brackets on the stove bottom 
(see Figure 12 below) 

Step 5: REMOVE MATERIALS FROM FIRE-

BOX 

-  Remove the packaged materials from 

inside of the fi rebox and set aside (propane 
conversion kit, log support cartons, log set 
and embers).

Step 9: VENTING SYSTEM INSTALLATION 

INSTALL VENTING COMPONENTS PER 

VENT MANUFACTURERS INSTRUCTIONS

The vent system may not service multiple 
appliances, and must never be connected to a 
fl ue serving a solid fuel burning appliance. 

CAUTION: Under no circumstances should 
these appliances be vented to other rooms 
or buildings.  These appliances must only be 
vented to the outside. Vent terminations shall 
not be recessed into a wall or siding.

IMPORTANT:  Do not exceed the maximum 
horizontal run allowed (see Figure 13 & 
14).

Support Brackets - Install vent support brack-
ets as specifi ed in the vent manufacturers 
instructions and the National Gas Fuel Code, 
USA - NFPA 54 / ANSI Z223.1, 7.6.5  Support 
of Gas Vents. Gas vents shall be supported and 
spaced in accordance with their listings and 
the (vent) manufacturer instructions.

General Information: These instructions 
should be used as a guideline and do not 
supersede local codes in any way. Install vent 
according to local codes, these instructions, 
the current National Fuel Gas Code (NFPA 
54 / ANSI-Z223.1) in the USA or the current 
standards of CAN/CGA-B149.1 and -B149.2 
in Canada. 

These stoves are designed, tested and listed 
for operation and installation with, and only 
with,  "Security Secure Vent

TM 

" or "Simpson 

Dura Vent" brand Components  (co-axial DV 
pipe with 4" inner & 6 5/8" outer diameter).  
These approved vent system components are 
labeled for identifi cation. DO NOT use any other 
manufacturer's vent components with these 
appliances. These stoves must be vented directly 
to the outside.

Содержание 775

Страница 1: ...OTICE POURRÉDUIREAUMINIMUMLERISQUED INCENDIE OUPOURÉVITERTOUTDOMMAGEMATÉRIEL TOUTE BLESSURE OU LA MORT POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser d essencenid autrevapeursouliquidesinflammablesdans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE SÉCURITÉ Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur Ne pas vous...

Страница 2: ...ts Note Installation and repair should be per formed by a qualified service person The appliance should be inspected annually by a qualified professional service technician Morefrequentinspectionsandcleaningsmay berequiredduetoexcessivelintfromcarpet ing bedding material etc It is imperative that the control compartment burners and circulating air passage ways of the appliance be kept clean S assu...

Страница 3: ...Pa 10 5 WC 2 61 kPa Propane 11 0 WC 2 73 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 1 6 WC 40 kPa Hi 3 5 WC 87 kPa Propane Lo 6 3 WC 1 57 kPa Hi 10 0 WC 2 49 kPa Table 3 Ne pas se servir de cet appareil s il a été plongé dans l eau complètement ou en partie Appeler un technicien qualifié pour inspecterl appareiletremplacertoutepartie du ...

Страница 4: ...2 mm SPECIFICATIONS CI1500DVF CI2500DVF Min Max BTU hr Input NG 17 500 28 000 25 500 38 500 Min Max BTU hr Input LP 20 500 27 000 26 500 34 500 DV Vent Size 4 inner 6 5 8 outer Room Fan CFM 150 150 Weight lb 206 290 EFFICIENCIES CI1500DVF CI2500DVF 67 NG 65 LP 67 NG 64 LP Steady State Efficiency Note Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject ...

Страница 5: ...00DVF CI2500DVF A minimum 10 254 mm B minimum 14 1 4 362 mm 17 1 4 438 mm C minimum 15 7 8 403 mm 19 483 mm D minimum 4 102 mm 4 102 mm E minimum 2 51 mm 2 51 mm F minimum 4 102 mm 4 102 mm G minimum 0 0 mm 0 0 mm H minimum 62 1575 mm 62 1575 mm I minimum 28 1 2 724 mm 34 1 2 876 mm J MAXIMUM 48 1219 mm 48 1219 mm 10 254 mm Figure 2 CLEARANCES TO COMBUSTIBLE MATERIALS FLOOR PROTECTION The location...

Страница 6: ...nalvent location restrictions refer to Figure 5 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a guidelineanddonotsupersedelocalcodesin anyway Installventaccordingtolocalcodes these instructions the current National Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CGA B149 1 and B149 2 in Canada Side Elevation View QUESTION...

Страница 7: ... i w t n e v e r p o t d e d n e m m o c e r m m 9 2 2 9 n o i t a s n e d n o c w o d n i w t i f f o s d e t a l i t n e v o t e c n a r a e l c l a c i t r e V D l a t n o z i r o h a n i h t i w l a n i m r e t e h t e v o b a d e t a c o l r e t n e c e h t m o r f m m 8 5 4 s e h c n i 8 1 f o e c n a t s i d l a n i m r e t e h t f o e n i l m m 8 5 4 8 1 m m 8 5 4 8 1 t i f f o s d e t a l...

Страница 8: ...sediment and more Certainly no one unfamiliar and unqualified should attempt sizing or installing gas piping The gas supply line should be plumbed from thefuelsourcetotheareawheretheappliance is to be installed per requirements outlined in NFPA 54 latest edition USA and B149 latest edition Canada Open both Latches as shown WARNING NEVER OPERATE APPLIANCE WITHOUTTHEFRONTGLASSENCLOSURE PANEL IN PLAC...

Страница 9: ...actory on both models see Figure 11 SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile TH TP TH TP ON OFF SWITCH OPTIONAL THERMOSTAT OR REMOTE SWITCH CONTROL RECEIVER Figure 10 Blower Wiring Diagram RELIEF DOOR Theloweraccess doorhingesopen to access Valve Controls Lower Access Door Figure 12 Step 8 INS...

Страница 10: ...ce for Natural Gas and 36 for Propane Gas before the first elbow The horizontal run may extend up to 20 feet 6 meters and include a vertical rise of up to 40 feet 12 meters see Figure 13 Horizontal termination must meet the criteria shown in Figures 4 and 5 Approved vent systems must terminate above and including the heavy line in Figure 13 Two 45 degree elbows may be substituted for each single 9...

Страница 11: ...nversion Kit for 6 I D 1 insulation SV4CCK2 Factory Built Chimney Conversion Kit for 7 I D 1 insulation 8 I D 1 insulation 6 I D 2 insulation SV4CCK3 Factory Built Chimney Conversion Kit for 10 I D 1 insulation 7 I D 2 insulation 8 I D 2 insulation Model Brand SIMPSON DURA VENT Description 934 Masonry Chimney Conversion Kit 931 Factory Built Chimney Conversion Kit A for 6 I D 932 Factory Built Chi...

Страница 12: ...ack 904B 24 Pipe Length Black SV4L36 36 Pipe Length Galvanized 903 36 Pipe Length Galvanized SV4LB36 36 Pipe Length Black 903B 36 Pipe Length Black SV4L48 48 Pipe Length Galvanized 902 48 Pipe Length Galvanized SV4LB48 48 Pipe Length Black 902B 48 Pipe Length Black SV4LA 6 Adj Pipe Length Galvanized 908 6 Adj Pipe Length Galvanized SV4LBA 6 Adj Pipe Length Black N A N A SV4LA12 12 Adj Pipe Length ...

Страница 13: ...rol valve is located in the lower control compartment To access the valve open the lower access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Figure 20 Ember Strip Rear Log Figure 21 Left Front Log Figure 22 2 Place the largest log onto the rear log stoppers see Figure 20 Ensure that the grooves on the bottom of the log aligns onto the corresponding places on the r...

Страница 14: ...the cor responding pin on the rear log and align it withtheindentationonfrontleftlogasshown in Figure 26 8 Install the front right twig onto the cor responding pin on the right front log Align thetwigwiththeindentationonthefrontright log as shown in Figure 27 9 Place the glowing embers on the burner as shown in Figures 28 29 One package of ember material has been included with this log set You wil...

Страница 15: ... switch MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Figure32 Proper PilotFlameAppearance Figure 33 Burner Flame Appearance Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be yellow Air shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter ...

Страница 16: ...Y HEAVY AND MAY REQUIRE A MINIMUM OF TWOPEOPLETOLIFT ONEPERSONONEACH SIDE THE CI1500 SERIES CAST TOP WEIGHS 20 POUNDS AND THE CI2500 SERIES CAST TOP WEIGHS 40 POUNDS B Locate the ash lip from packaging Step 2 Remove the 2 bolts from the tapped holes in theashlip Aligntheashlipbelowthefirebox as shown in Figure 36 the tapped holes in ash lip should align with corresponding slots below firebox Reins...

Страница 17: ...U GAZ A EVACUATION P N 9 1452A SERIAL NUMBER NOMBRE DE SERIE XXXXX XXXXX IIIIIIIIIIIIIIIIIIII XXXXXXXXXXXXXXXX P N 9 1452A MODEL NO CI2500DVF Series MANUFACTURED AT Burlington WA FOR USE WITH NATURAL GAS EQUIPE POUR GAZ NATUREL ALTITUDE MIN GAS SUPPLY PRESS WC PRESS MIN D ALIMENTATION CE MANIFOLD PRESSURE WC PRESSION CE TUBULURE CE MANUFACTURER S RECOMMENDED ORIFICE SIZE DIMENSION DE L INJECTEUR R...

Страница 18: ...P N 775 147M REV C 11 2004 1110 West Taft Avenue Orange CA 92865 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information ...

Отзывы: