Chapter 4 - page 7
DISCOVERY manual
4
D-H002
.0
607E
N
The following variables are shown:
•
Act.no.
: sequence number for the actions in this route
•
RunDst
: current distance travelled in mm
•
Speed1
: left wheel speed in mm/s
•
Speed2
: right wheel speed in mm/s
NOTE
•
Use the "Straight" option as little as possible. If it really is necessary, for example to get it through a doorway,
make the distance travelled as small as possible. Once through the doorway, continue with left or right wall
following or "Ultrasonic L". Programming it like this will improve the accuracy of the route to be travelled.
There are two ways of stopping:
•
PR, collision point
: let the barn cleaner bump into the collision point; this point is also stored in the memory.
Try to use as many collision points as possible within the shed. When approaching such a collision, press the
"PR" button. The Discovery is now anticipating a collision point and will move more slowly. If there is a bit of
wheel spin when traversing the route, the barn cleaner will then still keep going until the collision point.
•
Start/Stop, stopping manually
: a certain distance travelled is stored in memory via this action.
4)
Corner R 90
: pre-programmed turn to the right by 90°.
•
Positive value = turn right
•
Negative value (-) = turn left
1
The following variables are shown in this menu:
•
Act.no.
: sequence number for the actions in this route
•
Corner
: angle of turn (variable and adjustable)
•
Radius
: the radius of the turn (variable and adjustable) that the barn cleaner will make:
0 = on the spot
300 = about one of the drive wheels
600 = a sweeping curve
•
Back
: the distance (adjustable) that the barn cleaner first goes backwards before making the turn (needed if
the barn cleaner comes up against an obstacle).
•
SAVE
: stores the given gyroscope value. The direction the barn cleaner is facing must now be correct (adjust
by hand if necessary).
5)
Corner L -90
: pre-programmed turn to the left by 90°.
Please refer to point
for more information about the variables.
6)
Corner R 180
: pre-programmed turn to the right by 180°.
Please refer to point
for more information about the variables.
7)
Corner L -180
: pre-programmed turn to the left by 180°.
Please refer to point
for more information about the variables.
1) Any numerical value may be entered.
Содержание 5.4001.0010.1
Страница 2: ......
Страница 4: ...ii D H002 0607EN...
Страница 6: ...List of included amendments iv D H002 0607EN...
Страница 10: ...List of illustrations viii D H002 0607EN...
Страница 12: ...List of tables x D H002 0607EN...
Страница 16: ...Safety xiv D H002 0607EN This page intentionally left blank...
Страница 20: ...Introduction xviii D H002 0607EN...
Страница 21: ...xix General view D H002 0607EN General view Figure 1 Discovery barn cleaner floor mounted charger unit...
Страница 22: ...General view xx D H002 0607EN...
Страница 24: ...Registration xxii D H002 0607EN...
Страница 32: ...Installing the components Chapter 2 page 6 2 D H002 0607EN This page intentionally left blank...
Страница 40: ...Description of components Chapter 3 page 8 3 D H002 0607EN Figure 3 7 PCB connectors multiboard ADS3800A...
Страница 62: ...System operation Chapter 4 page 22 4 D H002 0607EN This page intentionally left blank...
Страница 64: ...Service and maintenance Chapter 5 page 2 5 M HE 008 0606 This page intentionally left blank...
Страница 68: ...Troubleshooting 7 2 7 M HE 008 0606 This page intentionally left blank...
Страница 69: ...M HN 008 0606...
Страница 70: ...M HN 008 0606 LELY INDUSTRIES NV Weverskade 110 3146 PA Maassluis NL 31 0 10 5996333 Fax 31 0 10 5996444...