30
frequency is 445MHz; if RPT Type is “SING”, receive
and transmit frequency are both 450MHz.
Note: Offset frequency setting is only available in VFO mode. It
cannot be set in already programmed memory channels. When
using the programming software, you must specify both
Scan Mode (SCN MD): Menus 23
Scan mode allows you to monitor several channels more
efficiently. Channels are scanned until activity is detected
on a channel. Depending on the scan mode, scanning may
continue after a specific length of time, or it will only
continue when the channel is inactive.
Scan Mode:
Select the scan mode in Menu23. There are
two modes:
Time operated (TO): Scanning stops when an active
channel is encountered. The scan will pause for five
seconds, then scanning will continue, even if the
channel is still active.
Carrier operated (CO): Scanning stops when an
active channel is encountered. Scanning resumes
after two seconds of channel inactivity.
The default setting is “TO”.
Note: Press any key except
▲
or
▼
to stop scanning.
Scan Type: You may select two different scanning ranges:
VFO frequency scan: All frequencies on the band
will be scanned.