20
9.4
Motion detector activated for presence verification
Symptom
Cause and / or remedy
LED is on during WALK TEST, but no
alarm is triggered
In case of
presence verification
an alarm is only triggered, if
no
motion
has been detected over the programmed period (
time-
out can be selected according to section 6.7)
WALK TEST has been set, but LED is
not on
Power supply of the motion detector is missing (=> check cable,
connector and power supply)
Power supply not on since two minutes (stabilize time of PIR-
motion detector)
Alarming with announcement
„emergency call activated, sensor 1
activated “
Motion detector has been connected after the unit has been
switch on!
Alarming with announcement
„emergency call activated, sensor failure
“
Motion detector has been disconnected after the unit has been
switch on!
9.5
Motion detector used as an alarm-sensor (sensor-1)
Symptom
Cause and / or remedy
LED is on during WALK TEST, but no
alarm is triggered
Inactive waiting period
by switching on the unit or between two
alarms is not expired
Supervision has been temporarily deactivated (deactivation)
Supervision is deactivated at current position of the
selection
switch
(I/II/III) (
section 6.6)
Motion detection is programmed to
verify presence
(
section
6.7), an alarm is only triggered if
no motion
is detected over a
programmed time.
WALK TEST has been set, but LED is
not on
Power supply of the motion detector is missing (=> check cable,
connector and power supply)
Power supply not on since two minutes (stabilize time of PIR-
motion detector)
There is no motion and the WALK
TEST LED is not on, but alarming with
periodical announcement „alarm sensor
n
“ is spoken
Power supply of the motion detector is missing (check cable,
connector and power supply) => further announcement „power
failure “
The motion detector has been connected (additional
announcement „sensor 1 activated“ or disconnected (additional
announcement “sensor failure”) after power on => factory
setting automatically recognizes a connected Plug&Protect-
motion detector
„Alarm due to sensor
n
“ is announced,
but the motion detector has been
temporarily deactivated
The power supply of the unit has been cut off for a short period
The
function switch
has been switched to PROG or OFF after
temporarily deactivation.