Leitronic AG EasyAlarm EA-8-433 Скачать руководство пользователя страница 1

21 January 2008 

Issue No.: 8.32  

EA8-SENIOR-8-32-GB.doc 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

Motion detector  

 

Siren-/Switch 
module

 

Wired sensors

 

Alarm

 

Emergency 

call button

 

 

 

 

Guardian angel in case of an emergency 

Use instruction 
EasyAlarm SENIOR

®

 

LEITRONIC AG 

Swiss Security Systems 

Содержание EasyAlarm EA-8-433

Страница 1: ...sue No 8 32 EA8 SENIOR 8 32 GB doc Motion detector Siren Switch module Wired sensors Alarm Emergency call button Guardian angel in case of an emergency Use instruction EasyAlarm SENIOR LEITRONIC AG Swiss Security Systems ...

Страница 2: ...ive waiting period 13 7 3 Supervision mode 13 7 4 Alarm release 14 7 5 Alarm delay Pre warning period Entry delay 14 7 6 Phone connection 15 7 7 Alarm repetition 16 7 8 Test call 16 7 9 Dialling in check call 16 7 10 Answering an incoming call 16 8 Useful Notes 17 8 1 Tone dialling command 17 8 2 User information 17 8 3 Functional checks 18 8 4 Battery check replacement 18 8 5 Maintenance 18 9 Tro...

Страница 3: ...apartment The optional smoke detector protect against fire 9 EasyAlarm monitors for noise activity An alarm can be triggered if the selected noise level in the monitored room exceeds several times The alarm is passed on without any indication to the person inside the monitored room listening in connection acoustical monitoring of patient baby children or home security application If necessary a ha...

Страница 4: ...wer supply A transformer according to the safety regulation EN60950 provides power supply 9V battery is used as a back up in case of power failure It is located on the rear side oft the device 2 5 Safety notes Do not bring the device into contact with a liquid water Do not open the device exception opening of battery compartment Replace the 9V battery as soon as the announcement battery error is a...

Страница 5: ...function switch is on position ON pressing any key will start a test call Keys are marked with 1 2 3 4 5 6 7 8 9 0 in the following sections 4 Loudspeaker The integrated loudspeaker is used for voice guidance during the programming as well as for hands free communication during phone connection 5 Microphone Is used during hands free connection and for recording of individual message 6 LED Status o...

Страница 6: ...e to the other EXT port of the alarm unit Details according to section 11 3 Telephone connection 5 Plug enclosed telephone cord into Line Jack of alarm unit and connect it with the telephone network If you share line with modem telephone please proceed according to section 10 6 Program calling number s Details according to section 6 Slide function switch to PROG 7 Enter n selected calling number S...

Страница 7: ... COMBI WALK Test Wait at least two minutes after power up for the motion detector to be stabilised After this time check the entire area by observing the LED Adjust swivel if necessary 4 3 1 Activation of the motion detector EasyAlarm detects the connected motion detector automatically at power on factory setting Warning By disconnecting the motion detector during operation an alarm is triggered w...

Страница 8: ...equipment should be tested regularly at least once a week to determine if there are sources of interference and to protect against faults 5 3 Preparation for use 5 3 1 Installation of the battery a Open the WT 211 transmitter with a small Phillips screwdriver by removing the 4 screws Afterwards open the cover gently b Remove the PCB carefully from the base of the housing c Place the 3V Lithium bat...

Страница 9: ...rs put function switch to OFF and repeat point 1 to 5 Important notes Calling number 1 cannot be deleted due to safety reasons 6 1 1 Point ID Contact ID alarm protocol If the alarm should be transferred to a alarm organisation using the Point ID Contact ID protocol the alarm number has to be followed by key and the customer ID EasyAlarm forwards the protocol to this alarm number and connects herea...

Страница 10: ...number is busy and another call attempt is programmed the waiting period before re dialling is 30 sec If the calling number changes within the sequence dialling of a new number starts without delay 6 3 How to select user language How to record individual message An individual announcement can be recorded as follows 1 Shift function switch to PROG 2 Enter Current individual message will be announce...

Страница 11: ... type Message announce Zone x to modify press 5 Press and start learn in process according to the specified radio component A successful learn in will be confirmed with a beep tone By activating the transmitter again a loud beep tone will be generated as long you are within transmitting range You can control this way by reception range and to select the best suitable location of the unit 6 Slide f...

Страница 12: ...h on II Emergency button presence control acoustical monitoring Selection switch on III Emergency button presence control acoustical monitoring Acoustical monitoring locked on position I Presence verification locked on position III instead of presence verification an alarm shall be triggered if motion is detected n 4 8 12 B In case you would like to have an entry delay for the sensor 1 contact add...

Страница 13: ...ouncement of the monitored functions inactive waiting period will be restarted 7 Bypass waiting period and change to inactive supervision mode Attention by switching from activated to inactivated supervision mode an announcement of the supervision modes is made and the waiting period starts again 9 Bypass waiting period and change to active supervision mode Attention by switching from inactivated ...

Страница 14: ...arm triggers an alarm provided programming is set to presence verification section 6 7 Before starting the alarm there is a pre warning period of ten minutes If activation is detected motion detected or emergency button pressed within this period the alarm is triggered 6 Sensor 2 can be enabled as alarm sensor NO or NC 7 Noise monitoring according to section 6 6 To avoid false alarm close windows ...

Страница 15: ...ivated 0 Announcement of calling number sequence n Announcement of calling number n n 1 9 Following tone dialling command can be used for remote programming provided the programming is not blocked section 10 8 Trigger an alarm for test reasons Cause of alarm announcement alarm due to programming n followed by the new calling number announcement and change of calling number n Record individual mess...

Страница 16: ...aits for the PIN Code After entering the correct PIN Code EasyAlarm establishes a listening in connection Announcement to stop press 0 to speak press 1 If no tone dialling command is entered the phone connection will be terminated after two minutes connection time out The supervised person can also terminate the phone connection by pressing the emergency button Important In case that there are unc...

Страница 17: ...heck error Telephone line check after power on was negative dial tone missing Output activated The output is activated after power on PIN Request to enter PIN Codes by locked programme Power failure Mains power missing Mains power is tested after switching on the unit Programming deactivated PIN Request to enter PIN Code to unlock programming Sensor supervision activated Motion sensor is set to pr...

Страница 18: ... to active supervision mode an announce monitoring functions at current position of the selection switch I II III Supervision I II III deactivated Confirmation of DTMF 7 Switch to inactive supervision mode an announce monitoring functions at current position of the selection switch I II III Unacknowledged alarms n Quantity of unacknowledged alarms 8 3 Functional checks 8 3 1 Test call We strongly ...

Страница 19: ...e audible Calling number is wrong Called party is not answering the phone Remote access using dialling in not possible EasyAlarm is not responding to the call The dialling function is programmed for the two step modus section 10 7 2 Remote access using dialling in not possible disconnection after entering of PIN code Wrong PIN code entered call again EasyAlarm does not react on tone dialling comma...

Страница 20: ...red Supervision has been temporarily deactivated deactivation Supervision is deactivated at current position of the selection switch I II III section 6 6 Motion detection is programmed to verify presence section 6 7 an alarm is only triggered if no motion is detected over a programmed time WALK TEST has been set but LED is not on Power supply of the motion detector is missing check cable connector...

Страница 21: ...eat an alarm as long until an acknowledgement is received OFF ON PROG 9 7 1 3 5 3 Value OFF ON PROG Value Comment 0 EasyAlarm calls the alarm numbers within the calling number sequence just once 1 9 EasyAlarm starts calling the calling numbers within the calling number sequence until the alarm is confirmed by DTMF 0 or until the programmed value is reached factory setting 2 10 3 Entry Exit periode...

Страница 22: ...once WITHOUT cause of alarm 10 6 Shared line with telephone modem If you want to use EasyAlarm in combination with a downstream telephone modem you must set dialling delay as follows OFF ON PROG 9 7 1 3 2 4 Value OFF ON PROG Value Comments 0 No dialling delay factory setting 1 Dialling delayed Option PLUS 10 6 1 Wiring with cord with end sleeves 10 6 2 Wiring Switzerland with T T SW06 1 Plug adapt...

Страница 23: ...al a successful dialling in and switches in listening in connection factory setting 1 EasyAlarm establishes hands free connection announced by three gong signals 10 7 4 Handling of incoming calls Answering incoming call by pressing the emergency button or any key can be selected as follows OFF ON PROG 9 7 1 3 7 2 Value OFF ON PROG Value Comment 0 EasyAlarm is not responding by activation of the em...

Страница 24: ...sequence will be announced followed by the request to enter DTMF n to confirm change If you do not confirm within 10 seconds or if another key is pressed the message programming abort will be announced In this case the old value remains active n Comment Programming according to 0 Calling number sequence max 9 digits Section 6 2 1 1 Calling number 1 max 24 digits 2 Calling number 2 max 24 digits Ca...

Страница 25: ...egular used room should be detected Notes Do not mount detector towards direct sunlight or near to heat sources Do not mount detector behind items like glass or curtains because the infrared beam cannot penetrate them Keep away pets like cats or dogs from the protected area Do not protect the same area by more then one detector because they can interfere 11 3 2 Installation Connect the cable of th...

Страница 26: ...D jumper over both pins 11 3 6 2 1 Mounting height If motion detector is not mounted at 2 5m you can adjust like this 1 Loosen the PC Board holding screw Slide the PC Board so that the plastic pointer on the right side is positioned at the appropriate scale position For higher than 2 5m Slide PC Board up For lower than 2 5m Slide PC Board down 2 Tighten the PC Board holding screw 3 Mount front cov...

Страница 27: ...syAlarm is manufactured and tested according to stringent quality rules If the unlikely case should occur that due to a manufacturing error the product is malfunctioning Leitronic AG will guarantee in addition to your sales distributor warranty of repairs without any labour or material costs for 2 years after date of purchase Warranty is only granted if the unit has been used as described in the i...

Страница 28: ... delay 9 22 Factory setting 2 12 14 16 19 21 Function switch5 6 7 9 10 11 12 16 18 20 21 Hands free 3 5 9 12 14 15 16 17 23 Incoming call 2 3 11 16 23 Individual message 2 5 6 10 15 17 how to record 2 10 Installation 2 6 8 25 Key 5 6 7 9 10 11 13 14 15 16 17 23 24 LED 5 7 8 10 13 15 19 20 26 Listening in 3 11 12 14 15 16 22 23 25 Loudspeaker 5 11 17 Microphone 5 Mode listening in 3 11 12 15 16 22 ...

Отзывы: