AES6800
+
Installation and Operation Manual
29
Chapter 4: Troubleshooting
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Common Problems and Suspected Failures
+
Pilot Lite Fails to Communicate with Installed Modules
Confirm that the following items are not the reason for the
communication failure:
•
Proper module slot has not been specified (
+
Pilot Lite is not
communicating with the appropriate slot). See your
FR6802
+
Frame Installation and Operation Manual
for more information on
slot identification.
•
COM port is used elsewhere (
+
Pilot Lite is not communicating
with the correct COM port).
•
Actual Slot ID and Frame ID do not match with the two DIP switch
settings in back of frame (
+
Pilot Lite is not communicating with the
appropriate slot and frame). See your
FR6802
+
Frame Installation
and Operation Manual
for more information on Slot ID and Frame
ID DIP switch settings.
•
ICE6800
+
module is installed in the frame (
+
Pilot Lite control is
disabled if an ICE6800
+
module is installed in the frame;
ICE6800
+
modules are used for CCS control).
+
Pilot Lite Does Not Find All Modules in Frame
If a discovery is started too soon after frame power-up,
+
Pilot Lite will
not find all the installed modules. Refresh
+
Pilot Lite (
File
>
Refresh
),
and ensure that installed modules are fully powered-up first before
discovery.
+
Pilot Lite or CCS Software Application Not Responding
+
Pilot Lite and CCS applications cannot run on the same PC at the
same time. Both applications can be installed, but only one can be
opened at a time.
+
Pilot Lite Cannot Control a Module Showing
in the Control Window
•
Did you physically configure the module for local control? If so,
configure the device for remote control.