AES6800
+
Installation and Operation Manual
23
Chapter 3: Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Setting Locally Accessible Parameters
describes AES6800
+
parameters that are accessible locally
via an on-board jumper. See
“Understanding Jumper Controls” on
for more information about setting these parameters via
jumper.
Table 3-1.
Locally Accessible Parameters
Parameter Name
Range
Description
Module status
• Red
Alarm condition exists
• Green
Operating properly
• Off
Not operational
• Red, blinking
Not operational; hardware fault
• Alternating
Module configuration ongoing
All OK
• Green
Signal present, no errors
CRC
• Yellow
CRC value of the data does not
match the CRC byte of the channel
status
• Off
CRC value correct
Validity
• Yellow
Incoming value not suitable for
conversion to analog audio signal
• Off
Data valid
Biphase coding
• Yellow
Biphase coding of incoming data
invalid
• Off
Biphase coding correct
Parity
• Yellow
AES stream parity bit is not set as
specified
• Off
AES stream parity bit correct
Confidence
• Yellow
Received data pattern is less than
one-half a bit period, indicating a
possible leak in signal strength,
high jitter, or insufficient EQ
• Off
Received data pattern correct
No Lock
• Red
Signal is not present