Toggle this button for displaying the tomography in dif-
ferent colour schemes. This function helps identifying
utilities in the tomography view.
Show/hide the layers and grid lines.
Change the depths.
☞
It is important to review the tomography of all
depth slices to find utilities in the correct
depth.
Tap button to pause an automatic animation to go
through all depth slices and start marking utilities.
Tap button to add the points of interest if they were not
added during the acquisition. Following options are
available in the current POI list:
•
Electromagnetic Location
is used to mark the
positions where the cable locator detects signals.
•
Trench Scar
is used to mark where the road surface
has been opened and covered. This option gives
ideas where utilities may be buried.
•
Hydrant
is used for giving additional information on
water pipes.
•
Manhole
is used for giving additional information
on water, sewer or drainage.
•
Lamp Post
is a great indication of power cables.
•
Other
: Add own POIs which do not belong to the
listed types.
Tap
Add Utility
and start marking the utilities shown in
each slice of the tomography view using either the pen
or your finger.
Export
to save your project results: