7.2.3
Adjusting the distance between ink jet and ink drop voltage detector
Attention
•
The following steps are only necessary after the entire drop production unit was
disassembled and reassembled e.g. after exchanging defective parts.
Do not carry out these steps for a standard ink jet adjustment!
After a reassembling of the drop production unit, it may be necessary to adjust the distance
between the ink drop voltage detector and the ink jet.
The optimal distance between ink jet (illustrated as blue dotted line) and the surface of the ink
drop voltage detector is
5/10 mm.
It must be less than
1 mm
.
Use the
set screw
to adjust the distance:
•
turn the screw to the right to increase the distance
•
turn the screw to the left to decrease the distance.
Set screw:
0,9 mm hex
Ink drop voltage detector
Ink jet
Distance
d
between ink jet
and the surface
of the ink drop
voltage detector
Optimum:
5/10 mm
Less than 1 mm!
d