13
_________________________________________________________________________________
3.4 Risk of collision
-
Adjust the drive speed so that it is safe in regards to the ground conditions.
-
The operator must follow all regulations concerning the use of safety equipment on the work
site.
-
Make sure that there are no overhead obstacles on the work site that could prohibit lifting of
the platform, or objects that might cause a collision.
-
Do not operate this access platform in the working area of another overhead lifting device or
similar equipment that is moving, unless this lifting device is secured so that there is no risk of
collision.
-
Beware of crushing hazard when holding the handrail of the platform in an eventual collision
situation.
-
When operating the lift, beware of eventual limited visibility and trapping hazard.
3.5 Risk of electric shock
-
This access platform is not voltage insulated nor protected against contact with voltage
carrying parts, or when approaching them.
-
Do not touch the machine if it comes in contact with voltage carrying electric line.
-
Persons on the platform or at ground level must not touch or operate the platform before
power has been cut off from the electric line.
-
During welding repairs, it is not allowed to use any part of this access platform as earth
conductor.
-
Do not use this access platform during thunderstorm or high winds.
-
Leave clearance to electric lines taking into account movements of platform, movements of
electric line, and high winds and gusts.
The minimum safety clearances to voltage carrying electric lines are shown in the following table.
These clearances must be respected.
VOLTAGE
MIN DISTANCE
0 - 1000 V
2 m
1 - 45 kV
3 m
110 kV
5 m
220 kV
5 m
400 kV
5 m
3.6 Risk of explosion/fire
-
It is not allowed to start the combustion engine / electric motor in a place where one can smell
LPG, petrol, solvent or other flammable substance.
-
Do not fill with fuel when the engine is running.
-
Charge the battery only in places with sufficient ventilation, where there is no open fire or no
works which could cause spark emissions (like welding).
-
In case of fire it is recommended to use carbon dioxide fire extinguisher. Dry powder
extinguisher can also be used but in this case the machine must be cleaned and inspected
thoroughly because the powder is corrosive.